3 phase 415v to 220v step down power transformer mining equipment step down transformer
USD $1,000 - $99,000 /Set
Min.Order:1 Set
Hebei SUN Electric Power Transformer Co., LTD.
SCB Indoor Using 630kva Dry Type Cast Resin Power Transformer
50kv three-phase transformer with price Dyn11 3 phase step down
High quality dry type transformer price 11kv phase cast resin dry-type transformer
High quality 690 volt dry type cast resin dry-type transformer
High quality dry type 15kva transformer price 11kv phase cast resin dry-type transformer
Details of 3 phase 415v to 220v step down power transformer mining equipment step down transformer
Characteristics of 3 phase 415v to 220v step down power transformer mining equipment step down transformer
1. High Insulation Strength
2. Strong Anti-Short-Circuit Capability
3. Outstanding Disaster-Proof Performance
4. Advantageous Environmental Related Performance
5. Maintenance Free
6. Low in Operational Loss and High in Operational Efficiency;
7. Low in Noise;
8. Small in Volume, Light in Weight, and Convenient for Installation and Adjustment;
9. Without needing any separate transformer room or any suspended core inspection, thereby saving holding lands;
10. Strong Overload Capacity
Standards of 3 phase 415v to 220v step down power transformer mining equipment step down transformer
Service condition | |
Normal Condition Ambient temperature Indoor -5°C to +40°C Outdoor -10°C to +40°C Humidity 90% Altitude ≤1000m Pollution Level I-Light Level II-Medium Earthquake UBC Zone 3
| Special Condition Ambient temperature Indoor -15°C to +40°C, -25°C to +40°C Outdoor -10°C to +50°C, -25°C to +40°C -40°C to +40°C Humidity 95%,98% Altitude ≤2000m, ≤3000m, ≤4000m Pollution Level III-Heavy, Level IV-Very Heavy Earthquake UBC Zone 4 |
Standard | |
IEC 60076-1 Power transformers-Part 1: General IEC 60076-2 Power transformers-Part 2: Temperature rise IEC 60076-3 Power transformers-Part 3: Insulation levels, dielectric tests and external clearances in air IEC 60076-4 Power transformers-Part 4: Guide to the lightning impulse and switching impulse testing IEC 60076-5 Power transformers-Part 5: Ability to withstand short circuit IEC 60076-10 Power transformers-Part 10: Determination of sound levels IEC 60076-11 Power transformers-Part 11: Dry-type transformers
IEEE C57.12.00 General Requirements for Liquid-Immersed Distribution Power, and Regulating Transformers IEEE C57.12.01 General Requirements for Dry-Type Distribution and Power Transformers Including Those with Solid-Cast and/or Resin Encapsulated Windings | |
Ratings | |
IEC Standard
Rated Voltage: 3.6 kV – 7.2 kV – 12 kV – 17.5 kV – 24 kV – 36 kV – 52 kV – 72.5 kV – 100 kV – 123 kV – 145 kV − 170 kV – 245 kV
Rated Insulation Level: Common Value: 20kV – 40kV – 60kV – 75kV – 95kV – 125kV – 145kV – 170kV – 250kV – 325kV – 380kV – 450kV – 550kV – 650kV – 750kV – 850kV – 950kV – 1050kV Across the isolating distance: 23kV – 46kV – 70kV – 85kV – 110kV – 145kV – 165kV – 195kV – 290kV – 375kV – 440kV – 520kV – 630kV – 750kV – 860kV – 950kV – 1050kV – 1200kV
Rated Frequency: 50Hz, 60Hz
Rated normal current: 1A – 1.25A – 1.6A – 2A – 2.5A – 3.15A – 4A – 5A – 6.3A – 8A – 10A – 12.5A – 16A – 20A – 25A – 31.5A – 40A- 50A – 63A – 80A – 100A – 125A – 160A – 200A – 250A – 315A– 400A – 500A – 630A – 800A – 1000A – 1250A – 1600A – 2000A – 2500A – 3150A – 4000A – 5000A – 6300A
Rated kVA 30kVA – 50kVA – 80kVA – 100kVA – 125kVA – 160kVA – 200kVA – 250kVA – 315kVA – 400kVA – 500kVA – 630kVA – 800kVA – 1000kVA – 1250kVA – 1600kVA – 2000kVA – 2500kVA – 3150kVA – 4000kVA – 5MVA – 6.3MVA – 8MVA – 10MVA – 12.5MVA – 16MVA – 20MVA
| |
IEEE Standard
Rated KVA Single-phase transformer: 5kVA – 10kVA – 15kVA – 25kVA – 37.5kVA – 50kVA – 75kVA – 100kVA – 167kVA – 250kVA – 333kVA Three-phase transformer: 15kVA – 30kVA – 45kVA – 75kVA – 112.5kVA – 150kVA – 225kVA – 300kVA – 500kVA – 750kVA – 1000kVA – 1500kVA – 2000kVA – 2500kVA – 3750kVA – 5MVA – 7.5MVA –10MkVA – 12MVA – 15MVA – 20MVA – 25MVA – 30MVA – 37.5MVA
Rated Voltage 1.2kV – 2.5kV – 5.0kV – 8.7kV – 15.0kV – 25kV – 34.5kV – 46.0kV – 69.0kV – 115.0kV – 138.0kV – 161kV – 230.0kV – 345kV
BIL 30kV – 45kV – 60kV – 75kV- 95kV – 110kV – 150kV – 200kV – 250kV – 350kV – 450kV – 550kV – 650kV – 750kV – 825kV – 900kV – 1050kV – 1175kV |
Related Transformer product in our company
Please click the following link for detailed information. We’re sure to have what you need when you need it.
Workshop for Dry Type Power Transformer
Certificate for 3 phase 415v to 220v step down power transformer mining equipment step down transformer
1. | Pre sale service |
a. | make technical solution |
b. | send quotation, technical data sheet and drawing |
c. | prepare power transmission plan, testing plan,and shipment plan |
2. | In sale service |
a. | supervise the manufacturing schedule totally in accordance with the plan |
b. | send photos to customer during every manufacturing process(hold point) |
c. | inform the customer one week before testinng. |
3. | After sale service |
a. | installation and commissioning, training the workers |
b. | quick response within 12 hours any time |
c. | provide 12 months gurantee period normally. |
Contact person: Ms.Kayla Wang
Tel: +86-312-6775757
Fax: +86-312-6775656
Whatsapp: +8615822478551
Skype: sales02(at)
Click following " Send " for more detailed informaiton and price directly!
Thank you!! :)