Distributed Data Acquisition Modules 8AIN 4 Pt Resistance Thermometer model
USD $1 - $10 /Piece
Min.Order:50 Pieces
Shenzhen King Pigeon Communication Co., Ltd.
data acquisition module rs485 modbus gsm energy meter remote transmitter king pigeon DAM124 series
GSM/GPRS outdoor power failure gsm sms alarm with 2 Relay control (250VAC/10A)
GSM Smart Energy Meter for 3 phase 4 wire smart energy meter
GSM transformer monitoring system for power distribution transformer monitoring system
Name: Distributed Data Acquisition Modules 8AIN 4 Pt Resistance Thermometer model
Model:DAM134
The DAM134 is for monitoring 8 analog inputs, measuring 4-channel Pt resistance thermometer of PT100, PT500, PT1000, CU50,CU100 or other PT Resistance Thermometers and transmit in ASCII data format to any RTU, SCADA, data monitoring, data loggers, PLC’s, process controllers and instrumentation that supports Modbus RTU Protocol over RS485 serial port. Powered up by 10~30VDC.
The DAM134 is used widely in industrial automation control systems. E.g.: Base Transceiver Station, diesel generator rooms, engine room, transformer substations, telecommunication equipment rooms, power supply systems and so on.
The DAM134 is an industrial class, high reliability, low-power consumption, high stability and high precision data acquisition module.
The DAM134 with fire retardant shell, standard 35mm DIN rail makes it easy to install in fields.
Mainly Features:
Specifications:
Items | Specifications |
Rated Power Input | 10~30VDC(Peak Voltage must≤40V) |
Power Consumption | Typically ≤0.3W |
Communication Protocol | Modbus RTU |
Modbus Address | 1~247 |
Data Format | n,8,1; e,8,1; o,8,1 or n,8,2 |
Communication Interface | RS485 |
Baud Rate | 1200, 2400, 4800, 9600, 19200, 38400Bps |
Analog Input | Default: 4~20mA, optional: 0~20mA, 0~5V, 0~10V |
Update Period | 0.12~2.4S |
Measurement Channel | 8AIN+4Pt |
Pt Resistance Thermometer | Default:PT100; Optional:PT500,PT1000,CU50,CU100 and other PT Resistance Thermometers |
Thermometer Wires | Default: 2 Wires; Optional: 3 Wires. |
Measurement Precision | ±0.2%FS |
Input Resistance | Analog channel: Voltage:>1KΩ, current ≤150Ω |
Overload Capacity | 1.2 times can sustained,3 times voltage can last 1 second. |
Isolated Type | Input / power / RS485 Serial port isolated. |
Withstand Tests | Input /Output /Shell: 2000VAC/min.; 500VDC>100 MΩ |
Operation Temperature | -20~70°C; |
Storage Temperature | -40~85°C; |
Altitude | 0~3000m |
Temperature Drift | ≤100ppm/°C |
Dimension | 118×72×59mm mm(HxWxD) |
Net Weight | 160g. |
Skype: GsmRtusystem