Horizontal Concealed Chiller Water Fan Coil For Comerses,Ducted Type Fan Coil
USD $70 - $245 /Piece
Min.Order:1 Piece
Shenzhen Jinhuali Refrigeration Plant Co., Ltd.
Horizontal Concealed Chiller Water Fan Coil For Comerses,Ducted Type Fan Coil
Horizontal Concealed Fan Coil Unit | |||||||||||
ModelHLC~ | 34HC | 51HC | 68HC | 85HC | 102HC | 136HC | 170HC | 204HC | 238HC | ||
Air flow (m3/h) | High speed | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | |
Medium speed | 255 | 383 | 510 | 638 | 765 | 1020 | 1275 | 1530 | 1785 | ||
Low speed | 170 | 255 | 340 | 425 | 510 | 680 | 850 | 1020 | 1190 | ||
Cooling capacity | High | W | 2247 | 3146 | 4146 | 5056 | 5955 | 7758 | 9657 | 11601 | 13965 |
BTU | 7669 | 10737 | 14150 | 17256 | 20324 | 26478 | 32959 | 39594 | 47663 | ||
Medium | W | 1620 | 2440 | 3290 | 4120 | 4850 | 6550 | 8190 | 9730 | 11580 | |
BTU | 5529 | 8328 | 11229 | 14062 | 16553 | 22355 | 27952 | 33208 | 39523 | ||
Low | W | 1310 | 2010 | 2650 | 3320 | 3900 | 5300 | 6610 | 7860 | 9350 | |
BTU | 4471 | 6860 | 9044 | 11331 | 13311 | 18089 | 22560 | 26826 | 31912 | ||
Heating capacity | High | W | 3251 | 4697 | 6189 | 7747 | 9491 | 11997 | 14732 | 18162 | 22137 |
BTU | 11096 | 16031 | 21123 | 26441 | 32393 | 40946 | 50280 | 61987 | 75554 | ||
Medium | W | 2350 | 3520 | 4530 | 6040 | 6850 | 9260 | 11740 | 14140 | 16360 | |
BTU | 8021 | 12014 | 15461 | 20615 | 23379 | 31604 | 40069 | 48260 | 55837 | ||
Low | W | 1620 | 2470 | 3130 | 4170 | 4740 | 6500 | 8180 | 9710 | 11290 | |
BTU | 5529 | 8430 | 10683 | 14232 | 16178 | 22185 | 27918 | 33140 | 38533 | ||
Surplus pressure of outlet (Pa) | Normal | 0 or 12 | |||||||||
High static pressure | 30 or 50 | ||||||||||
Cooling water temperature | 7-12°C | ||||||||||
Hot water temperature | 40-60°C | ||||||||||
Power supply | AC220V/50Hz | ||||||||||
Heat Exchanger | Type | 2.2mm copper pipes covered into aluminum fins, fin pitch 2.2mm | |||||||||
Water supply kg/h | 324 | 482 | 655 | 814 | 936 | 1278 | 1602 | 1915 | 2178 | ||
Water resistance kPa | 30 | 30 | 30 | 30 | 40 | 40 | 40 | 40 | 50 | ||
Working pressure | 1.6MPa | ||||||||||
Low static pressure FCU | Input power w | 37 | 52 | 62 | 76 | 96 | 134 | 152 | 189 | 228 | |
Motor power w | 10 | 16 | 20 | 25 | 30 | 20×2 | 25×2 | 30×2 | 40×2 | ||
High static pressure FCU | Static pressrue 30Pa | Input power w | 44 | 59 | 72 | 87 | 108 | 156 | 174 | 212 | 253 |
Motor power w | 12 | 20 | 25 | 30 | 40 | 25×2 | 30×2 | 40×2 | 50×2 | ||
Static pressure 50Pa | Input power w | 49 | 66 | 84 | 100 | 118 | 174 | 210 | 250 | 300 | |
Motor power w | 16 | 25 | 30 | 40 | 50 | 30×2 | 40×2 | 50×2 | 60×2 | ||
Fan motor quantity | 1 | 2 | 2 | 2 | 2 | 3 | 4 | 4 | 4 | ||
Noise dB(A) | Low static pressure | ≤37 | ≤39 | ≤41 | ≤43 | ≤45 | ≤46 | ≤48 | ≤50 | ≤52 | |
High static pressure 30Pa | ≤40 | ≤42 | ≤44 | ≤46 | ≤47 | ≤48 | ≤50 | ≤52 | ≤54 | ||
High static pressure 50Pa | ≤42 | ≤44 | ≤46 | ≤47 | ≤49 | ≤50 | ≤52 | ≤54 | ≤56 | ||
Pipe | Inlet/outlet water pipe | 3/4 "internal thread | |||||||||
Condensation water pipe | 3/4" external thread | ||||||||||
Dimension | L mm | 780 | 880 | 980 | 1080 | 1180 | 1480 | 1680 | 1780 | 1880 | |
W mm | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | ||
H mm | 260 | 260 | 260 | 260 | 260 | 260 | 260 | 260 | 260 | ||
20GP container loading quantity | 325 | 290 | 260 | 236 | 216 | 172 | 152 | 143 | 135 | ||
40GP container loading quantity | 666 | 591 | 531 | 482 | 441 | 351 | 309 | 292 | 277 | ||
Main materials | |||||||||||
Aluminium thickness:0.014mm, Copper tube thickless:0.35mm, Galvanized sheet: 1mm, Packing: Carton | |||||||||||
|
Note:
1. Cooling: Indoors DB 27°C,WB 19.5°C; Chilled water inlet/outlet temp. 12°C/7°C.
2. Heating: Indoors DB WB 21°C, heating water inlet&outlet temperature 60°C/50°C;
3.The noise level based on: background noise 11.5Db(A) semi-anechoic room.
4. Water resitance refers to that of rated water flow volume;
5. Input power refers to that of High speed air flow;
6. Above parameters are for your reference to model choice of FCU with cooling and heating; Heating energy of one row is 40% of three rows'; Low static pressure air flow volume loss: 10%, high static pressure air flow volume loss: 20%.