Specifications
5kw diesel generator set
Portable type
For home use
CE certififcate
Recoil/electric start
Europ Home use portable 5kw diesel generator set
♦ Powered by 4-Stroke air-cooled Diesel Engine.
♦ Compact and portable power for emergency and home standby use.
♦ Circuit breaker protects overload operation.
♦ Emergency low oil alert warn the low lube oil level.
♦ Large muffler for quiet operation.
♦ AVR alternator provides stable voltage and current.
♦ Standard configuration of voltmeter.
Tech Specification
Model | PFD6000SE |
Frequency(Hz) | 50/60 |
Rated AC output(KW) | 4.5/5.0 |
Max. AC output(KW) | 5.0/5.5 |
AC voltage | 120,110,220,230,240 |
DC Output (V/A) | 12/8.3 |
Engine model | JD186 |
Engine type | Single-cylinder,4-stroke,Direct injection,air-cooled diesel engine |
Fuel tank capacity (L) | 16 |
Continuous work (h) | 7.8 |
Starting system | Electric starter with battery |
Lubrication Oil Volume [Liter] | 1.65 |
Noise Level at 7m(dB) | 70 |
Gross Weight(kg) | 170 |
Dimension(mm) | 915*540*740 |
20ft Container QTY | 72 |
40ft Container QTY | 144 |
Strong Power
All generator sets are equipped with four-stroke engines.
Low Noise Running
High effective combustion system ensures complete combustion, Besides, a large silencer dampens exhaust noise and engine sounds which are contained by a double-wall structure and absorbed by a liner.
Digital Control Panel
All the control units of the generator sets are on one panel, a monitor of the panel will display the real-time working data of the generator set such as its output voltage and current etc. Besides, the running trouble of the generator will also be displayed on the panel.
Low Oil Alarm System
Before the oil level drops to the limited level, the generator set will stop automatically. The whole set can be
restarted only if the oil is refilled.
Application of New AVR
The AVR (Automatic Voltage Regulator) not only can smooth the output but also can provide reasonable protec-tion against the overload of the whole set, thus avoid damage to the set.
Advanced Alternator Winding
Waveform distortion is kept at a minimum level and the output is stable. The winding design protects the generator from short circuits and provides a stable output while running inductive loads.
ATS (Automatic Transfer Switch)
On the inheriting of the original
general-purpose generator set, diesel generator sets with digital control panel can be equipped with a made ATS(automatic transfer switch). ATS, in its preset intervals, can automatically check and monitor the running of the genset to ensure the genset in good working condition. Meanwhile, ATS will monitor the utility power, if utility power fails or the voltage and frequency of the utility power become abnormal, ATS will give commands to start the genset automatically.