Quality-assured professional mini suitable dry bath incubator
USD $150 - $500 /Unit
Min.Order:1 Unit
Taizhou Biomaker Scientific Instrument Co., Ltd.
Biological Indicator Incubator
is the biological indicator for supporting equipment, small size, light weight is suitable for pressure steam sterilizer biological indicator,biological indicator for ethylene oxide sterilization and other biological indicator sterilization effect detection and cultivation.
Technical parameters:
Model | BS-MINIB-100P Biological Indicator |
Adjustable Temperature Range | RT+5℃ ~100℃ |
Heating Time | ≤ 10min (from 20°C to 100°C) |
Uniformity Of Temperature | ≤±0.5℃ |
(detected at 56 ℃) | |
Temperature Stability | 0.1°C |
Block Temperature Uniformity | ±0.5℃ |
Temperature Display Accuracy | 0.1℃ |
Heating Time | <6min (From 20℃ to 56℃) |
Model | BS-MINIB-100F | BS-MINIB-100 | BS-MINIB-100I | BS-MINIC-100 | BS-MINIC-100I |
Temperature Control Range | R.T.+5°C ~100°C | -10°C ~100°C | |||
Temp. Control Accuracy@10 | ≤±0.5°C | ||||
0°C |
| ||||
Block Temp Difference@40°C | ≤±0.3°C | ||||
Display Accuracy | 0.1°C | ||||
Timing Range | 0-999min | ||||
Max. Temp. | 100°C | ||||
Max. Power | 60W | 120W | |||
Cooling Time. | fan cooling | natural cooling | ≤30min (from R.T. to R.T.-20°C) | ||
Net Weight: | ≤1.0kg | ≤1.4kg | |||
Max. Temp. | NO | NO | YES | NO | YES |
Block Selection | Refer to "Exchangeable Blocks for Mini Dry Bath Series" |
Exchangeable blocks for Mini series
Type | Dimension | Description | Remark |
BS-MINI-A | 0.2ml tube | 40×0.2ml | 8x0.2ml strip |
BS-MINI-B | 0.5ml tube | 24×0.5ml | |
BS-MINI-C | 1.5ml tube | 15×1.5ml | |
BS-MINI-D | 2.0ml tube | 15×2.0ml | |
BS-MINI-E | cuvette | 8~12.5×12.5mm | |
BS-MINI-F | 15ml tube | 4x15ml | cover cannot be closed |
BS-MINI-G | 50ml tube | 2x50ml | cover cannot be closed |
Customized blocks |
Product features:
1. Unique design, small size, light weight, convenient movement, suitable for all occasions.
2. LCD display, temperature and time display simultaneously.
3. Automatically fault detection and buzzer alarm, temperature calibration function.
4. Timing function, 0~999min
5. 24V DC power supply input, low power consumption, built-in over-temperature protection device, safe and reliable.
6. A variety of standard sample blocks for your choice, convenient replacement, the hole of block can be customized according to the size of tubes.
Q: What after-sales service can be provided by BIOMAKER ?
A: The after-sales service of BIOMAKER is divided into two parts: technical support and maintenance.
Q: What about the technical support and maintenence?
A: Sometimes users will get some problems when they operate the instruments which are unfamiliar or first time use, users can send us emails or call us about detailed information. We will provide users solution or operation video.
For so many years’ experience, our instruments works well during warranty period. If there any parts are broken during warranty period, we would like to provide spare parts for free.