WCB400 Multifunctional Basis Material Mixing Station
USD $100,000 - $800,000 /Set
Min.Order:1 Set
Luoyang Mingyang Engineering Machinery Co., Ltd.
Characteristics:
(1) The machine is mounted with non-scaleboard twin shafts horizontal compulsion mixer. The plant is designed into module type with reason layout in which each module is an independent function unit. It is easy to transfer and install. And it has the characters of accurate count (electronic and cubage count), uniform mixing and well applicability.
(2) This machine suit to be used to mixing various steady soil materials, and is widely used in the construction projects of expressway, airport, hi-speed railway, and especially, it suit the project that there is larger workloads and building site is relative fixed.
(3) The machine adopts “industrial computer + PLC + specialize counting meters” control form instead of traditional “VB language program” control, which greatly increases reliability and stability of the system.
(4) All processes of material match, count, transportation, mixing and discharge are operated in airproof conditions to prevent environment from pollution.
Technical Parameters:
Model | WCB400 | |||||
Productivity (m3/h) | 400 | |||||
Structure type | Module and Moveable | |||||
Full power (KW) | 105 | |||||
Full weight(t) | 35 | |||||
Mixer | Type | Non-scaleboard Twin Shafts Horizontal Compulsion Mixer | ||||
Model | BG400 | |||||
Max. aggregate (mm) | 65 | |||||
Motor power (kW) | 2×30 | |||||
Hopper cubage × Num. | 4×12 m3 | |||||
Count type | Frequency vary speed adjust, Automatic cubage count | |||||
Frequency vary speed adjust, computer control automatic electronic count | ||||||
Proportion error | Cubage count | Gravel≤3% Powder≤2% Water≤2% | ||||
Electronic count | Gravel≤2% Powder≤1% Water≤1.5% | |||||
|
|
|
|
|
|
|
Note:
1. Full power does not include helix feed part.
2. Number and cubage of the aggregate storage, powder storage, and machine lay is optional.
3. Powder feeding type may be chosen to use packed or unpacked cement.
4. The parameters above may be amended and actual data will be according to the product.