Diese Genset Mitsubishi 375kva to 1875kva
Negotiable /Set
Min.Order:1 Set
Shenzhen Genor Power Equipment Co., Ltd.
Diese Genset Mitsubishi 375kva to 1875kva
The specification of Mitsubishi Diesel Genset
1)Type:open,sound proof,weather proof
2)Power:375kva to 1875kva
3)Rated voltage:: 220V/380V, 230V/400V, 240V/415V
4)Frequency:50Hz/60Hz
5)Rated speed:1500rpm/1800rpm
6)Output type: single phase/AC three phase
7)Steel structure base
8)Optional:fuel tank,battery,charger
The specification of engine:
1) engine model: Mitsubishi
2) engine part :water tower,fan,fuel tank
3) governor system:electrical or mechanical governor
4) aspiration mode:natural, turbocharged
5) start method: 12V/24V DC electric starting
6) low fuel cnsumption,low noise,small volume,light weight
7)3 filter( air cleaner,fuel cleaner,oil cleaner),quality certification, Garantiekarte, using instructions
The specification of alternator:
1)alternator model: stamford, Leroy, Marathon.Engga
2)regulator: AVR automatic voltage regulating
3)insulation degree: H degree
4)power factor:3 phase 4 wire
5)Motor: bronze brushless
6) IP21-23 enclosure
Control System
Manual/Automatic start & stop controller
Various Monitor Meter and Optional Switch
Remote control interface and Remote monitor/Remote Sense/Remote Meter (Optional)
MCCB for Short circuit & Overload (optional)
High water temperature alarm, Low oil pressure alarm, over speed alarm and other kind of alarm
optional:
1)Auto-remove Monitor Panel
2)Auto Transfer System(ATS)
3)Auto-combine Cabinet
4)Sound proof canopy
5)Intelligent controlling system
Genset Model | Prime Power | Standby Power | Engine | Fuel Consumption | Cylinder No. | Displacement | Bore X Stroke | ||
KW | KVA | KW | KVA | (g/kwh) | (L ) | (mm) | |||
GNRM413 | 300 | 375 | 330 | 413 | S6B3-PTA | ≤211 | 6 | 14.6 | 135*170 |
GNRM500 | 360 | 450 | 400 | 500 | S6A3-PTA | ≤213 | 6 | 18.6 | 150*175 |
GNRM550 | 400 | 500 | 440 | 550 | S6A3-PTAA | ≤213 | 6 | 18.6 | 150*175 |
GNRM650 | 480 | 600 | 520 | 650 | S6R-PTA | ≤206 | 6 | 24.5 | 170*180 |
GNRM750 | 520 | 650 | 600 | 750 | S6R2-PTA | ≤205 | 6 | 30 | 170*220 |
GNRM825 | 600 | 750 | 660 | 825 | S6R2-PTAA | ≤211 | 6 | 30 | 170*220 |
GNRM908 | 660 | 825 | 726 | 908 | S12A2-PTA | ≤214 | 12 | 33.9 | 150*160 |
GNRM1125 | 800 | 1000 | 900 | 1125 | S12H-PTA | ≤206 | 12 | 37.1 | 150*175 |
GNRM1375 | 1000 | 1125 | 1100 | 1375 | S12R-PTA | ≤205 | 12 | 49 | 170*180 |
GNRM1500 | 1100 | 1375 | 1200 | 1500 | S12R-PTA2 | ≤205 | 12 | 49 | 170*180 |
GNRM1650 | 1200 | 1500 | 1320 | 1650 | S12R-PTAA2 | ≤205 | 12 | 49 | 170*180 |
GNRM1650 | 1200 | 1500 | 1320 | 1650 | S16R-PTA | ≤207 | 16 | 65.4 | 170*180 |
GNRM1875 | 1300 | 1625 | 1500 | 1875 | S16-PTA | ≤207 | 16 | 65.4 | 170*180 |
GNRM2100 | 1500 | 1875 | 1680 | 2100 | S16-PTA2 | ≤207 | 16 | 65.4 | 170*180 |
GNRM2250 | 1600 | 2000 | 1800 | 2250 | S16-PTAA2 | ≤207 | 16 | 65.4 | 170*180 |
Open Type Mitsubishi Diesel Genset