1500kva UK Generator With Perkins Diesel 4012-46TAG2A Engine
USD $115,240 - $146,850 /Set
Min.Order:1 Set
Shenzhen Genor Power Equipment Co., Ltd.
1500kva UK Generator With Perkins Diesel 4012-46TAG2A Engine
Product Description:
1. Inbuilt-muffler,compact arrangement and well performance;
2. With high anti-corrosion function,the hinge meterial is duralumin which has
been dealt with positive;the bolts and screws are both coped with anti-rust treatment for the power generator set;
3. strechable sealed edges;
4. The design enables maintainence much more comfortable
5. engine coupled with Stamford/Leroy Somer/Faraday/Cedex alternator
6. Low fuel consumption and noise of the power generator set
7. Emission meets the German TALuft standard
8. ATS power Generator Set
9. CE Certificate
10. ISO9001:2008
11. CCEC OEM Service Offered Industry Power Generator Set
Our Industry Power Generator Set mainly is powered by Cummins, and Doosan come from Korea,couple with Stamford, Leroy somer and Cedex alternator.
Power range is from 10kva to 2500kva.
| |
Genset Model | GNRP1500 |
Prime Power | 1505KVA/1204KW |
Standby Power | 1656KVA/1325KW |
Rated Voltage | 400/230V |
Frequency | 50Hz |
Radiator | 50 centigrade |
Charge Alternator | 24V |
Dimension(L*W*H) (mm) | 5000*2200*2530 |
Net Weight (kg) | 12428 |
Diesel Engine | |
Brand | UK Imported |
Model | 4012-46TAG2A |
Governor Type | Electronical |
Rotating Speed | 1500 rpm |
Engine Cooling Method | Water-cooled |
Displacement(L) | 45.8 |
Bore×Stroke(mm) | 160×190 |
Alternator | |
Brand | Stamford |
Model | PI734C |
Power Factor((COS Phi) | 0.8 |
Excite Type | Brushless SHUNT |
Connecting Type | 3 Phase & 4 Wires |
Insulation Degree | H/H |
Enclosure Degree | IP23 |
The components of the genset | |
1.Diesel Engine 2.Alternator 3.Control Panel |
Control Panel:
1.Auto start when power goes out
2.Auto stop when power comes back on
3.Worldwide technical support with programmable software download
4.Full online documentation
5.Trouble shooting symbols to assist owner on concerns with the generator
6.Safety shutdown feature to protect the engine and generator from damage
7.Totally digital with few points of contact to the engine to increase reliability
8.Exercise features and daily start and stop programmable
Standard configuration of generator :
1. Starting system: DC alternator is used to start engine
2. Short circuit protection: MCCB air switch
3. Cooling system: combined cooling water tank fitted to meet the requirement of radiation at ambient temperature 40°C
4. Filter system: oil, fuel and air filte
5. Accessories: exhaust elbow, bellow, muffler
Our Factory