Water Cooled Diesel Engine Self Generator with CE and ISO
Negotiable /Set
Min.Order:1 Set
Shenzhen Genor Power Equipment Co., Ltd.
Water Cooled Diesel Engine Self Generator with CE and ISO
1) Control system:
a) Automatic alarm system: the unit has the acousto-optics alarm system and
arrestor for any situation as the start defeat, the water is over temperature, the oil
pulls down, over speed, over load and over current
b) Operation display:
i) Unit voltage, tri-phase load current and frequency display
ii) Water temperature, oil pressure display
iii) Fuel level, fuel temperature display
iv) Audible and visual alarm lamps and buzzers
2) Supply standard collocation:
a) Diesel engine with all accessories, 3 filter, electric systems
b) Alternator
c) Steel structure
d) Fan and water tank cooling system
e) Flange connector
f) 12 / 24V starting motor and charge engine
g) Air cleaner, fuel cleaner, oil cleaner
h) On-board control panel
i) MCCB air conservation switch
j) 12 / 24V starting accumulator and battery line
k) Set shock absorber
l) High-efficient silencer
3)standard configuration of cummins diesel self generator
a) Starting system: DC alternator is used to start engine
b) Short circuit protection: MCCB air switch
c) Cooling system: combined cooling water tank fitted to meet the requirement
of radiation at ambient temperature 40°C
d) Filter system: oil, fuel and air filter
e) Accessories: exhaust elbow, bellow, muffler
Genset model | GNRC |
Type | open/sound proof/weather proof |
Genset output power range | 20kva to 1000kva |
Rated voltage | 220/380V,230/400V,240/415V,120/240V |
Frequency | 50/60HZ |
Power factor | 0.8 |
Rated speed | 1500/1800rpm |
output type | AC three phase/single phase |
Motor | brushless |
Frequency | <3% |
Frequency at stable state: | <0.5% |
Frequency deviation at instantaneous state | ≤+10% |
Frequency return time | ≤3s |
Voltage deviation at stable state | ≤±1% |
Voltage deviation at instantaneous state | ≤+20% |
Voltage return time | ≤4s |
Voltage modulation | ≤0.3% |
The specification of engine self generator
Model | 4B3.9-G,4BT3.9-G,4BTA3.9-G,6BT5.9-G,6BTA5.9-G,6BTAA5.9-G,6CTAA8.3-G,6LTAA8.9-G, NTA855-G, KTA19-G, KTAA19-G, KT38-G, KTA38-G, KTA50-G |
Cooling Method | water cooled |
Rotating speed | 1500/1800rpm |
Governor system | electrical or mechanical governor |
Aspiration mode | natural aspirated or turbocharged |
Starting method | 12/24V DC electric starting |
Stroke | 4 stroke |
The specification of alternator:
Brand | Stamford, Leroy semor, Maraton etc. |
Regulator | AVR automatic voltage regulating |
Excite type | pret or shunt |
Connecting type | 3PH star, 3PH-DELTA |
Steady frequency change | 0-5% |
No load voltage | ≥95%-105 |
Steady voltage | ≤±1 |
Insulation degree | H degree |
Exclosure degree | IP23 |