Double sealing Eurovent certified Cycling energy reclaim wheel
USD $200 - $3,000 /Set
Min.Order:1 Set
Beijing Holtop Artificial Environment Technology Co., Ltd.
3A melocular seive coating European certificated air to air energy recovery wheel
3A coating air to air heat recovery wheel, CE approved and Eurovent certified
aluminum rotary heat exchanger, 90% high efficiency heat exchanger
Self-cleaning double sealing system AHU part aluminum foils air to air vent
Eurovent certification industrial air duct heat recovery wheel
Features and specifications of Double Sealing System 3A mole sieve moisture total heat type energy reclaim exchanger
1.Double Sealing System
2..Purge Sector
3. Laminar Flow Channels
Specifications and dimensions
Model | Rotor diameter(mm) | Wheel length(mm) | Wheel width(mm) | Wheel height(mm) | Vot./Hz | Power(Kw) | Kg |
HRT-500 | 500 | 600 | 340 | 600 | 380v/50Hz | 0.09 | 42 |
HRT-600 | 600 | 700 | 340 | 700 | 380v/50Hz | 0.09 | 59 |
HRT-700 | 700 | 800 | 340 | 800 | 380v/50Hz | 0.09 | 71 |
HRT-800 | 800 | 900 | 340 | 900 | 380v/50Hz | 0.09 | 82 |
HRT-900 | 900 | 1030 | 340 | 1030 | 380v/50Hz | 0.09 | 102 |
HRT-1000 | 1000 | 1130 | 340 | 1130 | 380v/50Hz | 0.09 | 130 |
HRT-1100 | 1130 | 1230 | 340 | 1230 | 380v/50Hz | 0.09 | 151 |
HRT-1200 | 1230 | 1330 | 340 | 1330 | 380v/50Hz | 0.18 | 169 |
HRT-1300 | 1330 | 1430 | 340 | 1430 | 380v/50Hz | 0.18 | 190 |
HRT-1400 | 1430 | 1530 | 340 | 1530 | 380v/50Hz | 0.18 | 205 |
HRT-1500 | 1530 | 1630 | 340 | 1630 | 380v/50Hz | 0.18 | 220 |
HRT-1600 | 1630 | 1730 | 340 | 1730 | 380v/50Hz | 0.18 | 239 |
HRT-1700 | 1730 | 1830 | 340 | 1830 | 380v/50Hz | 0.25 | 266 |
HRT-1800 | 1830 | 1930 | 340 | 1930 | 380v/50Hz | 0.25 | 293 |
HRT-1900 | 1930 | 2030 | 340 | 2030 | 380v/50Hz | 0.25 | 320 |
HRT-2000 | 2030 | 2130 | 340 | 2130 | 380v/50Hz | 0.25 | 370 |
Model | Rotor diameter(mm) | Wheel lengt(mm) | Wheel width(mm) | Wheel height(mm) | Vot./Hz | Power(Kw) | Weight(Kg) |
HRT-2200 | 2230 | 2400 | 340 | 2400 | 380v/50Hz | 0.37 | 420 |
HRT-2400 | 2430 | 2600 | 340 | 2600 | 380v/50Hz | 0.37 | 500 |
HRT-2600 | 2630 | 2800 | 340 | 2800 | 380v/50Hz | 0.37 | 570 |
HRT-2800 | 2830 | 3000 | 340 | 3000 | 380v/50Hz | 0.37 | 860 |
HRT-3000 | 3030 | 3200 | 340 | 3200 | 380v/50Hz | 0.55 | 950 |
HRT-3200 | 3230 | 3400 | 340 | 3400 | 380v/50Hz | 0.55 | 1039 |
HRT-3400 | 3430 | 3600 | 340 | 3600 | 380v/50Hz | 0.55 | 1110 |
HRT-3600 | 3630 | 3800 | 340 | 3800 | 380v/50Hz | 0.55 | 1220 |
HRT-3800 | 3830 | 4000 | 340 | 4000 | 380v/50Hz | 0.55 | 1360 |
HRT-4000 | 4030 | 4200 | 340 | 4200 | 380v/50Hz | 0.75 | 1500 |
HRT-4200 | 4230 | 4400 | 340 | 4400 | 380v/50Hz | 0.75 | 1645 |
HRT-4400 | 4430 | 4600 | 340 | 4600 | 380v/50Hz | 0.75 | 1750 |
HRT-4600 | 4630 | 4800 | 340 | 4800 | 380v/50Hz | 1.1 | 1830 |
HRT-4800 | 4830 | 5000 | 340 | 5000 | 380v/50Hz | 1.1 | 1980 |
HRT-5000 | 5030 | 5200 | 340 | 5200 | 380v/50Hz | 1.1 | 2100 |
Selection software
Applications
Rotary heat exchanger can built in air handling unit(AHU)as a main part of the heat recovery section. Usually side panel of the exchanger casing is unnecessary, except that bypass has been set in AHU.