Large air volume clean air ventilation core
USD $80 - $1,000 /Set
Min.Order:1 Set
Beijing Holtop Artificial Environment Technology Co., Ltd.
Large air volume clean air ventilation core
- Aluminum heat exchanger
- High efficiency at 75%
- Resistance of pressure difference up to 2500Pa
- Air leakage below 0.6%
Energy saving high effciency plate heat exchanger, air to air unit
Sensible heat recovery air to air heat exchanger is used in comfortable air conditioning ventilation system and technical air conditioning ventilation system. Supply air and exhaust air totally separated, heat recovery in winter and cold recovery in Summer. Two neighbor aluminum foils form a channel for fresh or exhaust air stream. Heat is transferred when the air streams flow crossly through the channels, and fresh air and exhaust air is totally separated.
Features of cross flow air to air plate heat exchanger
1. Aluminum foils cross flow sensible heat exchanger
2. Heat recovery efficiency up to 75%
3. 2-side press shaping, double folded edge.
4. Resistance of pressure difference up to 2500Pa
5. Under pressure of 700Pa, air leakage less than 0.6%
Material type of cross flow air to air heat exchange core
B series (standard type)
Heat exchanger is made of pure aluminum foils, with galvanized end cover and aluminium alloy wrap angle. Max. air temperature 100°C, it is suitable for most of the occasion.
F series ( Anti-corrosion type)
Heat exchanger is made of pure aluminum foils cover by special anti-corrosion material, with galvanized end cover and aluminium alloy wrap angle. it is suitable for the corrosive gas occasion.
G series (high temperature type)
Heat exchanger is made of pure aluminum foils, with galvanized end cover and aluminium alloy wrap angle. Sealing material is special and allow the Max. air temperature to be 200°C, it is suitable for special high temperature occasion.
Heat exchanger size and air volume
INSTALLATION NOTES
Condensing water pan
When designing heat recovery functional section in air handling unit, under the heat exchanger should add the condensing water pan, in case of disorderly flow of condensing water
Heat exchanger vertical installation
When outdoor temperature is lower than indoor temperature, during heat exchanging if RA temperature is low enough (relative humidity 100%) then condensing water will come intobeing, once there is condensing water, heat exchange area inside heat exchanger is decreased, efficiency become lower and pressure drop increased, in order to eliminate the condensing water in time, heat exchanger vertical installation like the picture below is the best choice.
Aluminum sensible heat recovery heat exchange core specification
Model | A (mm) | B (mm) | C (mm) | Length per piece (L) | Optional spacing (mm) | Remarks |
HBS-ZF250/250 | 250 | 250 | 356 | <=400 | 4 | One module |
HBS-ZF300/300 | 300 | 300 | 427 | <=400 | 4 | |
HBS-ZF300/300 | 300 | 300 | 427 | <=500 | 5 | |
HBS-ZF350/350 | 350 | 350 | 498 | <=400 | 4 | |
HBS-ZF350/350 | 350 | 350 | 498 | <=500 | 5 | |
HBS-ZF350/350 | 350 | 350 | 498 | <=550 | 6 | |
HBS-ZF400/400 | 400 | 400 | 568 | <=400 | 4 | |
HBS-ZF400/400 | 400 | 400 | 568 | <=500 | 5 | |
HBS-ZF400/400 | 400 | 400 | 568 | <=550 | 6 | |
HBS-ZF500/500 | 500 | 500 | 710 | <=550 | 6.0, 8.0, 10.0 | |
HBS-ZF600/600 | 600 | 600 | 851 | <=550 | 6.0, 8.0, 10.0 | |
HBS-ZF700/700 | 700 | 700 | 993 | <=550 | 8.0, 10.0 | |
HBS-ZF800/800 | 800 | 800 | 1134 | <=550 | 8.0, 10.0 | |
HBS-ZF1000/1000 | 1000 | 1000 | 1417 | <=500 | 8.0, 10.0 | Four modules combined |
HBS-ZF1200/1200 | 1200 | 1200 | 1702 | <=500 | 8.0, 10.0 | |
HBS-ZF1400/1400 | 1400 | 1400 | 1985 | <=500 | 8.0, 10.0 | |
HBS-ZF1600/1600 | 1600 | 1600 | 2265 | <=500 | 8.0, 10.0 |
Installation
Pattern 1 and 2, to increase the heat exchange area, suitable for occasions requiring higher heat recovery efficiency,
however, air resistance will increase accordingly.
Pattern 3 and 4, to increase the front face area, suitable for occasions requiring large airflow, both air resistance and heat recovery efficiency remain stable.
Pattern 5, to increase both front face area and heat exchange area, suitable occasions requiring higher heat recovery
efficiency and large airflow.
Applications
Installed in air handling unit
Holtop plate heat exchanger can be used in the air handling unit (AHU) as a main part of the heat recovery section, and the bypass can be built in when required.
Installed in ducts
It can also be installed in the ducts of ventilation system as a main part of the heat recovery section. The installation is very flexible.
Holtop Factory
Holtop is one of the best manufacturer in ERV/HRV, heat exchanger and AHU area in China, founded in 2002, areas covered more than 30,000 square meters, turnover of 2012 is 42 million dollars, we have enthalpy testing lab. for products test. As a leader in energy/heat recovery equipments, we cooperate with more than 30 famous companies who located in Europe, the Middle east, Korea, Southeast Asia, Taiwan, etc. supplied equipment to Beijing Olympic and Shanghai Expo 2010, works together with domestic and international brands like Midea, Haier, Hitachi, etc.
Holtop partner
Holtop cooperate with world famous brand or offer OEM service including Hitachi, LG, McQuay, TRANE, Systemair, Aldes, York, Haier, Gree, MHI Group, Midea, Carrier, Dunham-Bush, etc.
Holtop certificate
Holtop products stand for TOP quality in heat recovery ventilation filed in China, certificated by CE, Eurovent, ISO and other different approved tests like anti-flaming test, anti-mold test, energy saving product test. Etc.
Holtop fair