Holtop energy saving single room heat recovery ventilator
USD $100 - $10,000 /Set
Min.Order:1 Set
Beijing Holtop Artificial Environment Technology Co., Ltd.
Suspended mounted air conditioning system heat recovery ventilatior with CE approval
Supply and exhaust ventilatin fan with F9 filter air curtain ventilation price
Slient Type Small Airflow Heat Recovery Fresh Air Ventilating Fan
Roof Heat Energy Recovery Fresh Air Ventilators Purify PM2.5
Basement garage ventilation system with positve pressure indoor
Holtop energy saving single room heat recovery ventilator
Feature of HOLTOP heat & energy recovery ventilation system
Effective Ventilation
Introduces outdoor fresh air into indoors, meanwhile exples the indoor stale air to outdoor, which makes you feel the comfort of the nature.
High efficiennt energy recovery
The bult-in high efficient heat exchanger can recovery the energy from outgoing indoor air to coming fresh air while ventilatin. It can recovery over 70% energy
Perfect silence design
It is deisgned with the worldwide fashiionable structure and manufactured by the accurate molidings. According to the principle of hydrokinetics, it achieves the perfect silent effect by using the micro-punch anechoic technology.
Air filtration and pruification
The inner air filters are professionally designed to remove the pollutants of the incoming air, providing you the fresh and clean air.
By-pass function
By-pass function enables the unit to make antual ventilation in suitable climates, which can prolong the service life of the heat exchanger
High airproof feature and easy manintenance
The heat exchangers is connected with the equipment by the in-mold rail, and embedded with the special soft and dense sealing materials. It can be drew out by hand and is easy to maintain. At the same time, it can ensure that tht fresh air and exhaust air are completely separated, avoiding the cross pollution.
Benefit of HOLTOP ERV(energy recovery ventilator)
◊ Brings a continuous supply of fresh air, filtered outside air into the home
◊ Suck indoor environmental contaminants for improved indoor air quality
◊ Pre-cool or pre-heat the fresh air when in summer and winter
◊ Designed to provide comfort in warmer humid climates and transfer incoming humidity back outdoors.
HOLTOP ERV(energy recovery ventilator) suitable for machine room,for classroom, conference room, hotel lobby etc.
1. Choose the proper installation types based on the building structure
2. Determine the fresh airflow required according to the use, size and number of persons
3. Select the right specifications and quantity according to the determined fresh airflow
Example
The area of a computer room is 60 sq. meters (S=60), the net height is 3 meters (H=3), and there are 10 per-sons (N=10) in it.
If it is calculated according to “Personal fresh air consumption”, and assume that: Q=70, the result is
Q1 =N*Q=10*70=700(m3/h)
If it is calculated according to “Air changes per hour”, and assume that: P=5, the result is
Q2 =P*S*H=5*60*3=900(m3)
Since Q2 > Q1 , Q2 is better for selecting the unit.
As to special industry such as hospitals (surgery and the special nursing rooms), labs, workshops, airflow re-quired should be determined in conformity with regulations concerned.
Holtop energy recovery ventilator keep your home cleaner and healther.
Let's improve indoor air quality together!!