Double way filter by-pass class G4+F7+H10 Three speed fan

Double way filter by-pass class G4+F7+H10 Three speed fan

USD $250 - $1,000 /Set

Min.Order:1 Set

Supply Ability:
3000 Set / Sets per Month
Port:
Tianjin
Payment Terms:
T/T Credit Card

Quick Details View All >

Condition:
New
Brand Name:
Benclimate
Place of Origin:
Guangdong, China
Use:
Room
Power Source:
Electrical
Power Type:
DC

Beijing Holtop Artificial Environment Technology Co., Ltd.

Credit Member 4 years
Business Type: Manufacturer
Beijing China
Main Products: Heat recovery ventilator ,energy recovery ventilator ,plate heat exchanger ,rotary heat exchanger ,air handling unit

Product Details

Specifications

1.Energy recovery airflow is 480/320/160m3/h
2.Three speed EC motor fan
3.Fresh air filter class is G4+F7+H10
4.220-240V

 Energy saving principle

Double way filter by-pass class G4+F7+H10 Three speed fan

 

Working principle of   Double way filter by-pass class G4+F7+H10 Three speed fan  

It can expel the stale air indoor out of room, meanwhile supplying the fresh air outside into the room, by using the advanced heat/energy recovering technology, the energy can exchange taking advantage of the difference of the temperature and humidity between indoor and outdoor air. By this means, it can not only smooth away the problem of indoor pollution, but also saving energy.

 

The main features  : 

1. Heating capacity of heat pump system 2480 W

2. Cooling capacity of heat pump system 2350 W

3. Power supply 220-240/1/50 V/Ph/Hz

4. External static pressure 130Pa

5. Three speed EC motor fan

6. Auto defrosting and bypass central controller

7. The airflow is controlled according to the ambient temperature.

 

Technicalparameters

 

Double way filter by-pass class G4+F7+H10 Three speed fan

 

 

 

 

 

The Configeuration

 

Double way filter by-pass class G4+F7+H10 Three speed fan

1. Crossflow heat exchanger                2. Supply fan                   3. Exhaust fan                           4. Fresh air filters

5. Return air filter                                     6. Bypass system         7. Compressors                        8. Evaporator 

9. Condenser                                          10. Connection box       11. Electrical heater                  12. Drain tray

13. Drain pump                                       14. Fresh air vent          15. Exhaust air vent                  16. Return air vent

17. Supply air vent                                  18. Access door             19. Cabinet

 

Dimensions Technicalparameters

Double way filter by-pass class G4+F7+H10 Three speed fan

 

Dimensions Controllerdescription

Double way filter by-pass class G4+F7+H10 Three speed fan

1. The airflow is controlled according to the ambient temperature.

2. Compressor and bypass control

3. The central controller can manage, monitor and control the whole system.
4. Functions of central controller
(1 Timely display of operation data
(2) Timely display of operation status of individual part
(3) Specific check to any data of ay unit
(4) Airflow adjustment according to ambient temperature
(5) Auto defrosting
(6) Auto bypass
(7) Heat pump
(8) Auto restart
(9) Filter monitor
G4: 3 months cleaning reminder
F7: 6 months cleaning reminder
H10: 12 months cleaning reminder
(10) Auto water drain
(11) Alarm
A. Fault alarm of refrigerantion system, high pressure or low pressure alarm
B. Communication failure alarm
C. Frosting alarm
D. Short connection or wrong connect of the sensors
E. Sensors lack or faults alarm
F. Over heating of electrical heater
G. Time resetting after euqipment faults
H. Fire alarm (if return air temperature higher than 45°C.)

Contact Supplier

Ms. Minzey Huang Chat Now
Telephone
86-20-39388201
Mobile
13710373840
Fax
86-20-39388202
Address
Room 2-1108 Industrial Plaza, Tian An Hi-Tech Ecological Park, Guangzhou,Guangdong

You May Like

New Products

Find Similar Products By Category

Home Appliances > Air Conditioning Appliances > Air Conditioners
Categories
Hi~