High Quality Multi Parameter Function Patient Monitor China
Negotiable /Unit
Min.Order:1 Unit
Guangzhou Yueshen Medical Equipment Co., Ltd.
High Quality Multi Parameter Function Patient Monitor China
Model: YSF5
Features
¨ 12.1' color TFT LED screen supports display max. 8 waveforms
¨ Visual On-display and integrated alarm light
¨ Display mode: standard, large font, trend table, OxyCRG, full leads ECG
¨ Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection
¨ Drug calculation, titration table
¨ Suitable for monitoring adult, pediatric and neonatal patient.
¨ Extended advance function: 2IBP, Depth of Anesthesia, EtCO2 , Nellcor SpO2
Standard Configuration of patient monitor china
¨ Anti-glare screen, Large capacity rechargeable battery, 3/5-Lead ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional Configuration:
¨ Dual IBP, Nellcor SpO2, MASIMO SpO2, Depth of Anesthesia Monitoring Module,
EtCO2 (Main-stream/Side-stream)
¨ Thermal printer (50 mm)
¨ Pediatric / neonatal accessories: reusable NIBP cuff & SpO2 probe; disposable NIBP cuff &
SpO2 probe
¨ Central Monitoring System
¨ Touch Screen
¨ Trolley/Wall Mount
Physical Specifications | |||||
Dimension and weight | Dimension | 340mm(W)*280mm(H)*130mm(D) | |||
Weight | Standard configuration: 4 kg | ||||
Operation environment | Power requirements | AC 100-240V, 50/60HZ, 60W | |||
Power | 90VA | ||||
Temperature | 0-40°C | ||||
Humidity | 0-93% non-condensing | ||||
Safety | Meet the requirements of IEC60601 series | ||||
Patient range | Adult, neonate and pediatric patients | ||||
Performance Specification | |||||
Display | 12.1’ (800 x 600 pixel) color TFT LED screen | ||||
Display mode | Standard, big font, trend table, full-lead ECG, Oxy CRG. | ||||
Interface
| Parameter cable interface AC power input socket Network interface | ||||
Battery | 1 internal large capacity rechargeable lithium battery | ||||
Alarm indicator | Visual on-display and integrated alarm light Audible alarm | ||||
Data storage
| 108 hour trend graph 168 hour trend table 2 hour trend wave 1024 alarm events | ||||
Printer
| Built-in 50mm thermal printer (option), 3 traces, print speed 12.5mm/s & 25mm/s & 50mm/s Print width: 50mm | ||||
Net working | Support connection to central monitoring station through LAN (TCP/IP) or wireless connection | ||||
ECG | |||||
Leads type | 3/5 lead : I, II, III, aVR, aVL, aVF, V | ||||
Sweep speed | 12.5mm/s, 25mm/s,50mm/s | ||||
Gain selection | ×0.25, ×0.5, ×1, ×2, Auto | ||||
ECG waveform | 2 channels | ||||
Operation mode | Diagnostic, monitor, surgery | ||||
Heart rate range | 0 - 350bpm | ||||
Accuracy | 1bpm or ±1% whichever is great | ||||
Alarm range | Audible and visual alarm, adjustable | ||||
ST/ arrhythmia | Real time S-T segment detection,pace detection and arrhythmia analysis | ||||
Protection | Against electrosurgical interference and defibrillation | ||||
Respiration (RESP) | |||||
Method | Thoracic impedance | ||||
Operation mode | Auto | ||||
Measurement range | Adult: 0-120BrPM; neonatal /pediatric: 0-150BrPM | ||||
Apnea alarm | Yes | ||||
Alarm | Yes, audible and visual alarm ,alarm events recallable | ||||
NIBP | |||||
Method | Automatic oscillometric | ||||
Operation mode | Manual / Automatic / STAT | ||||
Auto measure time | Adjustable | ||||
Measurement unit | mmHg / kPa selectable | ||||
Test interval | 1-480 minutes | ||||
Measurement range
| Adult: 0-300 mmHg ; Child: 0-240 mmHg ; Infant: 0-150 mmHg | ||||
Over-pressure protection | Double safety protection | ||||
Accuracy of blood pressure measurement | The mean error shall be less than ± 5mmHg The standard deviation shall be less than 8mmHG | ||||
Resolution | 1 mmHg | ||||
SPO2 | |||||
Measurement range | 0%-100% | ||||
Resolution | 1% | ||||
Accuracy | ±2% (70-100%, adult/pediatric, non-motion ) ±3% (70-100%, neonate, non-motion ) ±3% (70-100%, adult/pediatric/neonate, motion ) 0-69% unspecified | ||||
Alarm range | 1-100% | ||||
Pulse rate | Pulse range: | 0-350bpm | |||
Accuracy: | ±3bpm(non-motion) ±5bpm(motion ) | ||||
Temperature (TEMP) | |||||
TEMP range | 0-50°C | ||||
Resolution | 0.1 °C | ||||
Accuracy | ±0.1°C (excluding the sensor) | ||||
Channel | Dual-channel. provide T1;T2; T | ||||
IBP | |||||
Measurement range | -50-360mmHg | ||||
Channel | 2 channels | ||||
Pressure transducer | Sensitive :5 uV/V mmHg Impedance range :300-3000 Ω | ||||
Pressure names | ART, PA, CVP, RAP, LAP, ICP, P1, P2 | ||||
Alarm range | -10-300 mmHg | ||||
PR from IBP | Range & Accuracy: | 25 -200bpm ±1bpm or ±1bpm which is greater 201-350bpm ±2% | |||
Resolution : | 1bpm | ||||
Depth of Anesthesia (BIS) | |||||
EEG sensitivity | +/- 475μV | ||||
Noise | < 2uVp-p (1-150 Hz) | ||||
CMRR | > 100 dB | ||||
Input impedance | > 50mohm | ||||
Sample rate | 1024 samples/s, 16 bits |
portable icu patient monitor
Other models for option:
YSF6
YSF8
YSF8-S
YSF9
YSF15
patient monitor
patient monitor price
multi-parameter patient monitor price
monitor patient