solar inverter
USD $426 - $427 /Unit
Min.Order:1 Unit
Hefei Jntech New Energy Co., Ltd.
Solar inverter 1kW
Off Grid inverter equipments are the key devices of a solar power system; The solar power off grid systems are often used in remote area, pastoral area, Border, Island areas, and places shortage of electricity; The solar system may be used for houses, office, BT station and so on; In case of trouble repairing, the areas requests power system must be reliable enough, such as big temperature difference between day and night, high altitude may results problems of heat distribution, insulation and long way transport, so a qualified inverter comes important as so far. Our Off Grid Inverter range is from 0.3kVA to 60kVA, please contact us to get more information and make inquiry
Features
High-frequency conversion, High conversion efficiency
System has RTC function, to check current time and manage to change the time parameters
Setting to open/off machine function
With bypass Grid power connection as option
Multi protection functions, under/over voltage, over load, shortage, reverse polarity and over heat protections or warning buzzer. And all protection would be auto recover itself
Technical Specifications
Model | Unit | JNOG481K | |
Rated Output Capacity | kVA | 1 | |
DC Input | |||
Rated input Voltage | V | 48 | |
Under Voltage | V | 43.2 | |
Under voltage Recover | V | 50.4 | |
Overvoltage | V | 70 | |
Grid Bypass Connection | |||
Allow Voltage range | V | 230 ± 15% | |
Allow Input frequency | Hz | 50 | |
Working Method(Optional) | / | 2A,2B | |
Auto switch time | Ms | ≤5 | |
AC Output | |||
Rated Output Voltage | V | 230 | |
Voltage Accuracy | % | 230± 3% | |
Rated Output Frequency | Hz | 50 | |
Frequency Accuracy | Hz | 50± 0.04 | |
Output Wave | / | Pure sine wave | |
Inverter Efficiency | % | ≥85% | |
Peak factor(CF) | / | 3:1 | |
Output current THD | % | <3% (linear load) | |
Dynamic Response | % | 5% | |
Overload Capacity | % | 125% for 1min | |
System | |||
Isolation | Vac | 1500Vac 1min | |
Ambient temperature | °C | -25°C~+55°C | |
Environmental humidity | % | 0~95%,Non-condensing | |
Altitude | M | < 6000 | |
Earthquake Ability | g | 0.2 | |
Noise level | °C | <45dB at 1 meter | |
Protected | / | Under/over voltage, over load, shortage, reverse polarity, over heat | |
Communication & Mechanicals | |||
Standard Comm. Interface | / | / | |
Optional Comm. Interface | / | / | |
Dispay | / | LCD | |
Waterproof and Dustproof | / | IP20 | |
Installation method | Kg | Wall Mounted | |
Reference size | mm | 400 X 330 X 166 | |
Reference Weight | Kg | 21kg | |
Note:1 for Grid Power prior, 2 for Inverter Power Prior, 2 for Without of Prior, A for Normal Switch(100ms), B for Static switch (5ms), C for Without of Switch |