ZHE type chlorine generator water treatment equipment
USD $3,200 - $4,500 /Set
Min.Order:1 Set
Shandong Jinhaosanyang Environmental Protection Machine Co., Ltd.
Chlorine generator water treatment equipment
Project description
Chlorine dioxide is recognized as the medical and health industry, food processing, drinking water, industrial circulating water and sewage treatment, sterilization, disinfection, ideal deodorant by the US Food and Drug Administration, U.S. Environmental Protection Agency. Chlorine dioxide with the characteristics of board-spectrum, fast-acting, non-toxic, small dosage, long efficacy etc. Its bactericidal capacity is of existing Chlorine-based disinfectants 2-5 times, no chloroform and other carcinogenic substances in the process, the security was as the AI level by the world health organization.
The violet series Chlorine dioxide generator is the only special equipment for a high-temperature aeration technology to produce Chlorine dioxide disinfectant, it’s fully enclosed design, no noise and leak pollution, safe and reliable operation, these features make purple series chlorine dioxide generator as an alternative liquid chlorine, sodium hypochlorite generator, the electrolytic chlorine dioxide generator ideal products.
Chlorine dioxide generator performance and characteristics
Chlorine dioxide disinfectant application range:
1) Chlorine dioxide in the great PH value range (6-10) has a strong bactericidal ability. The bactericidal effect of chlorine dioxide can not be influenced by the media PH value, in the cooling water of the alkaline processing solutions, with chlorine dioxide to control bacteria and algae grow much better than chlorination.
2) Chlorine dioxide is not with ammonia and amine compound reaction, and its bactericidal effect is not subject to the influence of the ammonia. In addition, chlorine dioxide and other organic in water reactions is weaker than chlorine, so can reduce the usage. This is particularly suitable for the ammonia plant, refinery or ammonia leak circulating cooling water system.
3) Chlorine dioxide can kill microorganisms; also can decomposition of the residue of the cell structure, spermicidal and veridical effect, which can effectively control the growth of bacteria, algae and slime.
4) Chlorine dioxide and humus and organic reaction hardly divergent organic chloride does not produce carcinogenic effects of chloroform.
5) The elevated temperatures, the sterilization ability of the chlorine dioxide.
Chlorine dioxide generator introduction:
This technique is a chemical production of chlorine dioxide disinfectant technology, its fully consider the mechanism of the reaction between the substance, starting from the best reaction process of raw material, adopt advanced vacuum mixing technology, when the two kinds of chemical raw materials from the raw material tank, the regulating valve into the reaction chamber, the reactant molecules in the role of a stirrer, violent collision, the reaction generating chlorine dioxide; Since the reaction chamber is a vacuum, the generated chlorine dioxide gas is rapidly separated from the reaction solution, the chemical equilibrium is further moved to the direction of the generated gases, intense collision between molecules and the rapid separation of the product gas, greatly exacerbated positive reaction proceeds, so that the overall reaction rate is accelerated, increased yield of chlorine dioxide, and lower operating costs.
The device is equipped with a jet pump designed by jet principle, the chlorine dioxide gas into the jet pump from the reaction was mixed with water, forming the disinfectant, and get into the water to be treated.
The water to be treated unit consumption of the amount of drugs a, it should be the actual measured, the following data for conventional statistics, in the specific selection of equipment, can be used as a reference:
Objects | Drinking water | Industrial circulating water | Swimming pool water | Hospital sewage |
Unit dose consumption(g/t) | 1-2 | 1-5 | 2-5 | 20-40 |
3. Device application data
ZHE type (manual)
model | ZHE 30 | ZHE 50 | ZHE 100 | ZHE 200 | ZHE 300 | ZHE 400 | ZHE 500 | ZHE 1000 | ZHE 2000 |
Disinfection gas production(g/h) | 30 | 50 | 100 | 200 | 300 | 400 | 500 |
1000 |
2000 |
Drinking water treatment capacity(t/h) | ≤30 | ≤50 | ≤100 | ≤200 | ≤300 | ≤400 | ≤500 |
≤1000 |
≤2000 |
Swimming pool water treatment capacity(t/h) | ≤15 | ≤25 | ≤50 | ≤100 | ≤150 | ≤200 | ≤250 |
≤ 500 |
≤ 1000 |
Hospital sewage treatment capacity(t/h) | ≤2 | ≤3 | ≤5 | ≤10 | ≤15 | ≤20 | ≤25 |
≤ 50 |
≤ 100 |