No smoke boiler, working simple vertical boiler
USD $5,000 - $200,000 /Set
Min.Order:1 Set
Liyang Weifeng Equipment Co., Ltd.
No smoke boiler, working simple vertical boiler
Applicable for all kinds of biomass fuel
Characteristics:
Energy-efficient: half way gasification complete combustion, quick warming of water heater, thermal efficiency over 90%; boiler body design structure maximum increase the heat transfer area, which let the heat fully transferred; specially set waste heat recovery device, smoke tube exhaust temperature lower than 120°C, and greatly reduce the cost of combustion.
Green environmental protection:boiler fuel is biomass fuel, cheap price, wide range source; special gasify structure ensure the fuel complete half way gasify combustion, no need tall chimney, only need to put the boiler exhaust port pick out of the room; and configuration our integrated dust control system, discharge invisible smoke.
Intelligent control: microcomputer one type operation, automatic feeding and autoignition, with temperature setting, cycle rev. stop, and warning functions, easily operation.
Safety and labor save: biomass fuel water heater is ordinary pressure boiler, no need fireman. It can automatically feeding and autoignition, only need to add raw materials 1-2 times, save the labor source.
Easily maintenance:it is vertical smoke pipe structure inner the boiler, hardly blocked by carbon deposit, set cleaning door in every hearth, easily overhaul and maintenance.
Using scope:
It is widely used in hotel, bath center, leisure clubs, mansions, apartments, factories, school, enterprise, government and home using hot water, bath and heating.
compared with other boilers
Parameters of big-size:
Item mode | SZSW -4S | SZSW -8S | SZSW -10S | SZSW -20S | SZSW -30S | SZSW -50S | SZSW -60S |
Kcal/h Rated power | 40000 | 80000 | 100000 | 200000 | 300000 | 500000 | 600000 |
Rated in/our water temp | 70/90 | 70/90 | 70/90 | 70/90 | 70/90 | 70/90 | 70/90 |
% Thermal efficiency | 88 | 88 | 88 | 88 | 88 | 88 | 88 |
Kgf/cm² Maximum working pressure | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
mm Water inlet | 25 | 40 | 40 | 50 | 65 | 65 | 65 |
mm Water outlet | 25 | 40 | 40 | 50 | 65 | 75 | 75 |
mm Blowoff valve diameter | 25 | 40 | 40 | 50 | 65 | 65 | 65 |
mm Floss hole | φ100 | φ120 | φ120 | φ120 | φ120 | φ150 | φ150 |
V Main fan electricity | 220 | 220 | 380 | 380 | 380 | 380 | 380 |
W Main fan power | 250 | 370 | 750 | 750high pressure fan | 1500 | 2200 | 2200 |
V Vice fan electricity | 220 | 220 | 220 | 220 | 220 | 380 | 380 |
W Vice fan power | 60 | 60 | 60 | 250 | 370 | 750 | 750 |
W Feed motor power | 120 | 120 | 120 | 180 | 180 | 180* 2 pieces | 180* 2 pieces |
mm Boiler dimensions | 560* 430* 1250 | 650* 520* 1400 | 760* 630* 1450 | 1560* 750* 1450 | 1700* 900* 1700 | 1950* 950* 1800 | 2400* 1140* 2000 |