lab digital thermostatic water bath heating bath circulating water bath closed system Heating Circulator UC Series 50~200
USD $3,000 - $5,000 /Unit
Min.Order:1 Unit
Xian Toption Instrument Co., Ltd.
closed liquid circulation system
Glass reactor chiller and heater
Refrigerated heater
chilller and heater
cooller and heater
50~200 ℃
Closed system Heating circulator UC Series 50~200 ℃
Description of heating circulator:
1. UC series with function of cooling down from high temperature and the temperature range from 300℃ to 50℃.
2. Equipped with heating and cooling system, large heat exchange area, rapid speed of heating-cooling, small demand of heat conducting medium.
3. Can heating-cooling continuously
4. The whole system is closed, there is no oil mist at high temperature, no volatilization of heat conducting medium at high temperature; With function of adjustable internal circulation PT100.
5. The whole system is a closed liquid circulation system with expansion tank, the expansion tank and liquid circulation are thermal insulation, do not participate in liquid circulation, regardless of high or low temperature, the medium in expansion tank is limited to 60℃.
Parameter of of heating circulator:
Model | UC-A1520 | UC-A2520 | UC-A3820 | UC-A6020 | UC-A9520 | UC-A13020 | UC-A20020 | |
Temperature range ℃ | 50℃~200℃ | |||||||
Controller | PID adaptive controller | |||||||
Temp. Control optional | Heat-conducting medium outlet temp. control | |||||||
Communication protocol | MODBUS RTU Protocol, RS 485 Interface | |||||||
Temperature feedback | Heat-conducting medium temperature feedback PT100 | |||||||
Temp. accuracy | ±0.5℃ | ±0.5℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±2℃ | |
Heating power | 15kW | 25kW | 38kW | 60kW Divide to two groups heating | 95kW Divide to three groups heating | 130kW Divide to three groups heating | 200kW Divide to four groups heating | |
Heater can be divided into groups. When the testing temperature reached to (setting temperature -5℃), it can close the most of heating duty and leave the next group to be PID fuzzy control. | ||||||||
Cooling capacity | 300℃ |
|
|
|
|
|
|
|
200℃ | 15kW | 25kW | 38kW | 60kW | 95kW | 130kW | 200kW | |
100℃ | 12kW | 20kW | 30kW | 48kW | 76kW | 100kW | 160kW | |
65℃ | 5kW | 8.5kW | 12kW | 19kW | 30kW | 40kW | 64kW | |
| There is a heat exchanger in the system and it needs water to cool. Open the water valve automatically according to demand. | |||||||
Circulation pump | Max50L/min 2.5BAR | Max110L/min 2.5BAR | Max110L/min 2.5BAR | Max250L/min 2.5BAR | Max250L/min 2.5BAR | Max400L/min 2.5BAR | Max400L/min 2.5BAR | |
Expansion tank volume | 35L | 65L | 90L | 160L | 240L | 300L | 500L | |
Heater | Orient electric heater | |||||||
Independent temperature limiter | LNEYA | |||||||
Cooler | Plate heat exchanger | |||||||
Operation panel | Display setting temperature and testing temperature; Touch screen display | |||||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure switch, overload | |||||||
Closed circulation system | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. | |||||||
Connection size | DN-25 | DN25 | DN25 | DN40 | DN40 | DN-50 | DN-50 | |
Dimension | 600*600*1250 | 600*600*1250 | 1200*750*1100 | 1200*750*1100 | 1400*750*1300 | 1400*750*1300 | 1500*850*1450 | |
Weight | 100kg | 130kg | 170kg | 285kg | 318kg | 450kg | 685kg | |
Power | AC380V 50HZ 15.7kW (max) | AC380V 50HZ 26.5kW (max) | AC380V 50HZ 39.5k (max) | AC380V 50HZ 63kW (max) | AC380V 50HZ 98kW (max) | AC380V 50HZ 135.5kW (max) | AC380V 50HZ 206kW (max) | |
Case material | Cold rolled steel painting | |||||||
Optional | Optional 7-inch color touch screen controller, temperature curve record, data export to excel format. | |||||||
Optional | SUS 304 SUS 304 case material | |||||||
Optional power | 220V 60HZ three-phase, 440V~480V 60HZ three-phase |
Model | UC-A1530 | UC-A2530 | UC-A3830 | UC-A6030 | |
Temperature range ℃ | 50℃~300℃ | ||||
Controller | PID adaptive controller | ||||
Temp. Control optional | Heat-conducting medium outlet temp. control | ||||
Communication protocol | MODBUS RTU Protocol, RS 485 Interface | ||||
Temperature feedback | Heat-conducting medium temperature feedback PT100 | ||||
Temp. accuracy | ±0.5℃ | ±1℃ | ±1℃ | ±1℃ | |
Heating power | 15kW | 25kW | 38kW | 60kW Divide to two groups heating | |
Heater can be divided into groups. When the testing temperature reached to (setting temperature -5℃), it can close the most of heating duty and leave the next group to be PID fuzzy control. | |||||
Cooling capacity | 300℃ | 15kW | 25kW | 38kW | 60kW |
200℃ | 13kW | 22kW | 32kW | 50kW | |
100℃ | 10kW | 17kW | 27kW | 40kW | |
65℃ | 4kW | 6kW | 11kW | 16kW | |
| There is a heat exchanger in the system and it needs water to cool. Open the water valve automatically according to demand. | ||||
Circulation pump | Max50L/min 2.5BAR | Max110L/min 2.5BAR | Max110L/min 2.5BAR | Max250L/min 2.5BAR | |
Expansion tank volume | 50L | 80L | 120L | 220L | |
Heater | Orient electric heater | ||||
Independent temperature limiter | LNEYA | ||||
Cooler | Plate heat exchanger | ||||
Operation panel | Display setting temperature and testing temperature; Touch screen display | ||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure switch, overload | ||||
Closed | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. | ||||
Connection size | DN-25 | DN-25 | DN-25 | DN-40 | |
Dimension | 600*600*1250 | 600*600*1250 | 1200*750*1100 | 1200*750*1100 | |
Weight | 115kg | 155kg | 195kg | 320kg | |
Power | AC380V 50HZ 16kW (max) | AC380V 50HZ 26.5kW (max) | AC380V 50HZ 39.5k (max) | AC380V 50HZ 63kW (max) | |
Case material | Cold rolled steel painting | ||||
Optional | Optional 7-inch color touch screen controller, temperature curve record, data export to excel format. | ||||
Optional | SUS 304 SUS 304 case material | ||||
Optional power | 220V 60HZ three-phase, 440V~480V 60HZ three-phase |
Photo of heating circultor
Packing of heating circulator
Toption Service:
We are professional lab solution provider & leader. Any inquire of lab equipment, please contact us.
Sincerely expecting your kind feedback, thank you.
Toption-Your Top Option!!!