Lab Analysis and Measurement Testing Equipment JK9870 auto Kjeldahl analyzer PRICE
USD $3,000 - $10,000 /Set
Min.Order:1 Set
Xian Toption Instrument Co., Ltd.
Cost Effective Semi-Auto Kjeldahl Nitrogen Analyzer JK9830 Kjeldahl semi-auto analyzer price
Kjeldahl Apparatus auto analyzer for determining protein JK9870 auto Kjeldahl analyzer PRICE
Auto kjeldahl analyzer with ISO certificate JK9870 auto Kjeldahl analyzer PRICE
clinical biochemical semi Automatic Kjeldahl Analyzer JK9870 auto Kjeldahl analyzer PRICE
Auto Kjeldahl Nitrogen Analyzer for Kjeldahl JK9870 auto Kjeldahl analyzer PRICE
Auto Kjeldahl Nitrogen Analyzer Kjeldahl protein analyzer JK9870 auto Kjeldahl analyzer PRICE
JK9870 auto Kjeldahl analyzer
Description of JK9870 auto Kjeldahl analyzer:
The working principle of JK9870 auto Kjeldahl analyzer is based on the classical methods, it's namely the "color method" developed auto Kjeldahl analysis system. It is consistent with national and international standards and methods of Kjeldahl nitrogen. It's a high-performance instrument due to the concept of its design and application of new technologies, therefore, its comprehensive technical performance and very competitive price even much better than the similar products which the oversea competitors standing behind; thus, it becomes a very reasonable and logical choice to the Chinese local users as an outstanding import substitution.
JK9870 SPECIFICATIONS
Name of Item | JK9870 |
Range of Analysis | 0.1—200 mg N |
Repeatability (RSD) | ≤1%(30mgN,0.1mol/L H+) |
Titration accuracy | 1 mu L / Step |
Ratio of Recovery | ≥99.5% |
The sample analysis time (cooling water temperature 18 ℃) | 4-6min |
Mode of Operation | Auto |
Calibration Mode of Titrant Concentration | Manual Input |
Display of Titration Curves | Yes |
Temperature Sensor | Yes |
Working Voltage | AC220V/50Hz |
Heating Power | 1600W |
Weight of Sample | Solid Sample ≤6g; Liquid Sample ≤20ml |
Optional EQUIPMENTS & ACCESSORIES
1. Sample mill,
2. Thermostatic heating digestion system,
3. Extraction apparatus
4. Neutrodyne system
5. Digestive tube stand
6. Digestive tube
7. Catalytic
8. Reflux funnel
JK9870A Specifications
Name of Item | JK9870A |
Analysis of the range | 0.1-200 mg N |
Repeatability (RSD) | 1% or less (30 MGN, 0.1 mol/L H +) |
Titration accuracy | Step 1 mu L / |
Recovery rate | ≥99.5% |
Sample analysis time (cooling water temperature 18 ℃) | 4 to 6 min |
Cooling water flow switch | Yes |
Cooling water flow rate | Yes |
Operating mode | Automatic/manual analysis |
Titrant concentration calibration method | Manual input/automatic calibration |
Digestive tube liquid automatic discharge | Yes |
Distilled from liquid temperature test sample | Yes |
Titration curve shows | Yes |
Alkali pipeline automatic cleaning | Yes |
The temperature sensor | Yes |
The cooling water system for intelligent interface | Yes |
The USB interface | Yes |
Heating power | 2000 w |
Weight of sample | Solid Samples ≤6g; Liquid Samples ≤20ml |
OPTIONAL EQUIPMENTS & ACCESSORIES
1. Sample mill
2. Thermostatic heating digestion system
3. Extraction apparatus
4. Neutrodyne system
5. Digestive tube stand
6. Digestive tube
7. Catalytic
8. Reflux funnel
ADVANTAGES & CHARACTERISTICS:
1. Addition of reagents, distillation, titration, analysis and calculation, record (data) storage, waste discharge, all the above-mentioned program can be accomplished by simply click on ONE BUTTON.
2. Display. 7-inch color touch screen, bilingal operating system (English & Chinese), interactive mode of operation.
3. Titration curve display. Real-time observation, analysis to the titration process to see whether it's successful or fail and figure out the reason through curve. It's also able to analyze and determine whether the choice of titration is correct through the curve.
4. High-integrated modular structure. Patented technology of "modular construction" is composed of steam section, titration section, control section, and crate section; therefore, the structure ensures reliable operation and easy maintenance.
5. Titration cup exposed structure. It's convenient for users to observe and take out cup for cleaning.
6. The whole system. The system adopts the CPC company (US) fast for fluid pipe, to ensure that the system not leakage and prolong the life of equipment. The unique color label and color ring system which is able to help user avoid twisting and wrong operation.
7. Patented technology. Siemens PLC Board technology applied enabling to protect the running reliability and stability completely.
8. Different pipes perform its own function. Steam, waste water adopts fluoride pipeline; the liquid portion selects the modified silica gel pipeline (which is made in USA) changing tube aging caused by the leakage, leakage of steam corrosion problems.
9. Pre-warming function. The instrument itself is able to pre-heat automatically, and keep the certain temperature as preset, prior to use; therefore, it may save time and energy for user.
10. Fertilizer (nitro) analysis mode. Addition of fertilizer analysis capability achieves multi-purpose instrument which may save considerable cost for user.
11. Multi-alkali adding technology. In the operation process, multi-alkali adding technology solves the problem of halfway quit in the analysis process which is due to shortage of alkali adding.
12.Patented technology. Vapor, liquid separator to reduce the area of the internal structure of the system of residual less, more conducive to ensuring the reliability of the analysis results.
SAFETY PROTECTION SYSTEM:
1. Electric leakage protection. It can prevent the damage caused by the system leakage of user to the greatest extent to protect the user's personal body safety.
2. Overtemperature protection system. It's composed of temperature sensor, CPU, overtemperature and overpressure protection system which is able to effectively prevent overtemperature and / or overpressure phenomena due to system failure to ensure a worry-free working condition for user.
3. Steam pot. Selection of platinum carbon fiber plastic die-cast, long-term temperature 300℃ without distortion. It is currently the first product which adopts such materials in mainland China.
4. Distillation System water shortage alarm function. When the water level is too low or dry, the distillation pot may stop working and alarm systems, which is able to prevent the harm caused by water shortage or dryness effectively.
5. Absence of protection of the digestive tube. When the digestive tube is not put in place, the system does not run, without alkali, distillation, wounding prevent wounding by reagent and / or contamination.