PID SSR Control Accelerated Weathering Aging UV Test Machine price
USD $4000 - $6000 /Set
Min.Order:1 Set
Flora Automatic Technology Co., Ltd
Product description
Programmable auto UVA lamp accelerated aging test chamber is applicable for the sunlight resistant test of nonmetallic materials and aging test of artificial light sources. A variety of industrial products can make the reliability test, and this product can simulate the product in the sun, rain, humidity and dew conditions, including damage caused by bleaching, color, brightness down, powder, crack, blur, brittle, intensity decreased and oxidation.
Applications
Simulate the sun, rain spray and condensation resulting damage to test the materials by exposure to sunlight with moisture and temperature.
To get the results of damage after several days or weeks which is equal to expose to outside for a few months. The damages include fading, discoloration, brightness down, powder, crack, blur, brittle, strength decreases and oxidation.
Provide reference with testing data for improvement of existing materials, or to assess the impact of changes in product durability and other aspects.
Standard Features
Item | Specification |
Outside dimension | 1300W×500D×1460Hmm |
Chamber material | SUS#304 stainless steel |
Temperature range | RT~70℃ |
Temperature fluctuation | ±2℃ |
Temperature control | PID SSR control |
Humidity range: | ≥95%RH |
Controller | Programmable controller, LCD touch screen |
Control mode | Balance temperature humidity control (BTHC) |
Test cycle setting | Exposure, condensation and water spray test cycle is programmable |
Lamp power | 40W/Piece |
Distance from sample to lamp | 50±2mm |
Centre distance between the lamp | 70mm |
Irradiance | 0.45~1.0W/m2 (optional) |
UV lamps | Imported Atlas UV-B: 280-315nm (8pcs, 1600h lifetime) |
Standard Specimen Size | 75×290mm (24pcs) or 75x150mm (48pcs), max. thickness 5mm |
Testing time | 0~999H, adjustable |
Protection system | Overload short circuit protection Over temperature protection Water lacking protection Earth leakage protection Auto shut off protection |
Design criteria:
UVA lamp accelerated aging test chamber
(1) ASTM D4587: Standard Practice for Fluorescent UV-Condensation Exposures of Paint and Related Coatings
(2) ASTM D4799: Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Fluorescent UV, Water Spray, and Condensation Method)
(3) ISO 4892-1: Plastics – Methods of Exposure to Laboratory Light Sources – Part 1: General guidance
(4) ISO 4892-3: Plastics - Methods of Exposure to Laboratory Light Sources - Part 3: Fluorescent UV Lamps
(5) ASTM D4329: Standard Practice for Fluorescent UV Exposure of Plastics
(6) AATCC TM186: Weather Resistance: UV Light and Moisture Exposure
(7) ASTM D5208: Standard Practice for Fluorescent Ultraviolet (UV) Exposure of Photodegradable Plastics
(8) IEC 61345: UV Test for Photovaltalic (PV) Modules