JK-WBN-150B New Thermostatic Water Bath(Luxury)
JK-WBN-150B New Thermostatic Water Bath(Luxury)
JK-WBN-150B New Thermostatic Water Bath(Luxury)

JK-WBN-150B New Thermostatic Water Bath(Luxury)

USD $139 - $230 /Set

Min.Order:1 Set

Supply Ability:
500 Set / Sets per Month
Port:
SHANGHAI CHINA
Payment Terms:
Credit Card

Quick Details View All >

Brand Name:
JKI
Model Number:
JK-WBN-150B
Place of Origin:
Shanghai, China

Shanghai Jingke Scientific Instrument Co., Ltd.

Business Type: Manufacturer,Trading Company
Shanghai China
Main Products: Magnetic Stirrer ,Water Bath ,Drying Oven ,Protein Analyzer ,Lab Instrument

Product Details

 

JK-WBN Series New Thermostatic Water Bath(Economy)

I. Scope of Application:

It is used for precise temperature keeping and auxiliary heating by industrial and mining enterprises, colleges and universities, scientific research institutes and various labs, etc.

 

II. Specification

 

Item no.

140339

140340

140341

140342

140343

140344

Economy

Luxury

Model

JK-WBN-150A

JK-WBN-300A

JK-WBN-600A

JK-WBN-150B

JK-WBN-300B

JK-WBN-600B

Voltage

AC220V±10%, 50Hz~60Hz

Input power

300W

500W

800W

300W

500W

800W

Temperature range

RT+5℃~99℃

RT+5℃~99

Display screen

LED

Display screen

Temperature stability

±0.5

±0.3℃

Resolution

0.1

Timing range

 

0~999min

Volume

5L

13L

28L

5L

13L

28L

Interior dimension L*W*H (mm)

300*150*150

295*235*200

495*295*200

300*150*150

295*235*200

495*295*200

Dimension L*W*H (mm)

550*250*220

580*320*270

800*500*300

550*250*220

580*320*270

800*500*300

Package size(mm)L*W*H

650*350*320

680*420*370

860*550*400

650*350*320

680*420*370

860*550*400

N.W

11kg

11.8kg

17.4kg

11kg

11.8kg

17.4kg

Price RMB/USD

1250/198

1500/238

1800/290

1450/230

1700/270

2000/318

 

III. Structural Description:

1. It has a stainless inner layer and the cover can be removed at random.

2. The temperature control is via the high-precision temperature control instrument. And the temperature control is precise and reliable.

3. Digital display. microcomputer controlled.

 

IV. Usage:

1.  Fill clean warm water into water tank up to 1/2 ~2/3 of the full height.

2.  Set the power switch to “ON” and then figures will appear on the temperature control instrument panel, indicating the power supply is on.

3.  Set temperature, When the measured temperature reaches the set temperature, the heating will be interrupted and the heating indicator will go out, and the temperature will become stable after 60 minutes of temperature keeping. If the temperature in the water tank exceeds the set temperature over 2 °C(alarm temperature can be set arbitrarily), the alarm indicator of the temperature control instrument is on and the power of the heater will be automatically switched off in the meantime. 

 

Symbol

Name

Setting range

Description

Factory set value

AL

Alarming setting

0-Full Range

0.0-Full Range

When temperature is beyond SP+AL,the ALM indicator turn on. The buzzer sounds and the heating power turn off.

 

CL

Refrigeration control setting

0-Full Range

0.0-Full Range

When the temperature less than SP+COL, the refrigeration point is turn on to  drive the compressor.

without this function

P

Proportional Band

1-Full Range

1.0-Full Range

Proportional control action. If P is larger, then the gain of system is lower. It only use on the heating side.

 

I

Integral Time

0-3600 seconds

Integrated time constant. I larger, then the integrated action is smaller.

 

D

Derivative Time

0-3600 seconds

Derivative time constant. D larger, then the derivative action is also larger D can overcome overshoot. I=0and D=0 is called half proportional control.

 

Ar

Overshoot Control(re-setting)

1-100%

At on-off PID control, the value of Ar is a constant which equals 1.5-2times of the ratio of on time to the on-off period in the equilibrium state, In the half proportional control, the Ar equals coefficient/P.

 

T

Heating period

1-300seconds

For the thyristor output it is abut 1-3seconds.For those equipment that the superfluous power provided is comparatively larger, select larger T would decrease the stable error caused by PID control.

 

Pb

Zero point adjust

(intersection)

-100-100

-100.0-100.0

When the zero error comparatively smaller and the full point error comparatively larger, to update this value should be needed. Ordinary for pt100 ,updating this value is rarely needed..

 

PK

Full point adjust(intercept)

-1000-1000

seconds

When the zero error comparatively larger and the full point error also comparatively larger, to update this value should be needed. PK=4000×(setting value-actual value)/actual value. For pt100 adjusting this value is need at first time.

 

Ct

Refrigeration control Time delayed

0-3600seconds

When measuring value reaches its alarm value, the alarm relay output will be +delayed this time…

Without this function

dp

The decimal point setting

0;1

When D=0 the display resolving power is 1°C and when DP=1 the display resolving power is 0.1°C

 

rH

The range setting

0-  400°C

0.0-400.0

Adjusting rH can make the instrument range equals 0-rH(°C)

 

LK

Password key

0-255

When LK=18 the parameters listed above then the above parameters can be updated.

  

 

V. Precautions

1. The shell of the water tank shall be grounded effectively to guarantee the safe use.

2. Before filling water, never press down the power switch so as to prevent the electrical heating tube from being burnt.

3. When any sound and light alarms are sent out from the water tank, please check whether the set temperature deviates from the normal range or not; if not, stop use and invite the professional personnel to inspect it or hand it over to our factory for repair.

4. Unless necessary, never disassemble the side plate of the temperature control unit so as to guarantee the safety

 

VI. Maintenance

1. Always keep the internal and external of the water tank clean; do not wipe the shell with the chemical solution, which can cause chemical reaction, to prevent any chemical reaction.

2. If the instrument is not to be used for a long time, cover it with a plastic thin film dust shroud and place it in a drying room so as to prevent the temperature control instrument from being moisturized and out of use.

3. The instrument is not suitable to be used in the environments of high voltage, heavy current, intense magnetic field or corrosive gases to prevent the instrument from being damaged by intervention and prevent the persons from the risks of the electroshock.

 

VII. Failure Handling Methods

Problems

Causes

Handling methods

1. No supply

1.The plug is not inserted well or the

  wire is disconnected.

1. Insert the plug and connect the  wire.

2. Fuse is open.

2. Replace the fuse.

 

2. The temperature in

  the cabinet does

  not increase.

1. The set temperature is low.

1. Adjust the set temperature.

2. The electric heater does not work.

2. Replace the electric heater.

3. The temperature control instrument

  does not work.

3.Replace temperature control

  instrument.

4. The cyclic fan does not work.

4. Replace the fan.

3.The set temperature has a big difference from the temperature in the cabinet.

1.The temperature sensor does not

  work.

1. Change temperature sensor.

2.The fine tuning potentiometer for setting temperature is not adjusted well.

2. Adjust the potentiometer.

4.The over-temperature

  alarm is abnormal.

1. The set temperature is low.

1. Adjust the set temperature.

2.The temperature control instrument

  does not work. 

2. Replace the temperature

  control instrument.

 

Contact Supplier

Mr. Leo Luo Manager Chat Now
Telephone
86-21-34637408
Mobile
18917902208
Fax
86-21-34637403
Address
Room A304, No.189, Xinjunhuan Road, Minhang District Shanghai

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Chemicals > Lab Supplies > Laboratory Thermostatic Devices
Categories
Hi~