Pipeline & Cable Locator TT-1360
Negotiable /Piece
Min.Order:1 Piece
Beijing Health Care Resource International Co., Ltd.
Pipeline & Cable Locator TT-1360
Main functions
1. Detect the route of underground pipeline cable
2. Measure the burying depth of underground pipeline cable
3. Identify the target pipeline cable under multiple underground pipeline cable condition
4. Detect and locate the insulation fault point of the underground pipeline cable
Technical specification of Transmitter
Signal frequency:
a. Injection method 480Hz,7.7KHz,31KHz ,61KHz
b.Induction method 31KHz,61KHz
c. Clamping method 31KHz
d. Fault Finding
Output Voltage 0-400Vp-p adjust according to the insulation condition
Output wave shape sine wave
Power source 11.1VDC 4.4AH Li-battery
Maximum output power 10W
Technical specification of Receiver
Power loss <1W
Power source 11.1VDC 1.8AH Li-battery
Max. burying depth for detecting 4.5 meters (normal condition)
Tolerance of burying depth for detecting ±0.05H ±5cm (“H” is pipeline burying depth)
Tolerance of route for detecting ≤ 5cm
The effective length under detecting pipeline route and depth with Injection method ≥10Km (normal condition)
The effective length under detecting pipeline route and depth with Induction method ≥3Km (normal condition)
The effective length under detecting pipeline route and depth with Clamping method ≥6Km (normal condition)
Insulated fault detecting ≥2 MΩ
Remark: Normal condition means that without insulation fault and other interference in the measuring range as detecting the pipeline.
Environmental request
Operating temperature -20 °C ~ +50 °C
Storage temperature -40 °C ~ +70°C
Relative humidity 10% ~ 0%
Atmospheric pressure 86~106KPa
Environment noise ≤ 60dB