Drip tapeNews IRRIGAZETTE N 73 - Lowest flow (than AquaTraxx-Toro and T-tape) PATHFINDER Labyrinth HDPE drip tape 6mil path 3000
USD $55 - $140 /Pallet
Min.Order:2 Pallets
PATHFINDER is a brand patented, bought from Nelson Irrigation USA and produced in Spain
Available in thicknesses 6000 (0.15 mm or 150 microns); rolls of 3200 meters and 8000 (0.2 mm or 200 microns); rolls of 2500 meters.
We recommend Pathfinder as has quality level of AquaTraxx and T-tape. In this study (IRRIGAZETTE N°73 - NOVEMBER/DECEMBER 2002) you can see we are superior in strength, durability, distribution uniformity and reliability:
Ura-T-Pathfinder. 3000 Path. 06-06-30-340-3000
Model 16-06-20-125-3000
Nominal flow rate per outlet (l/h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.13
Nominal pressure (bar) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.7
Wall thickness (mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.152
Spacing between two emission devices (cm) . . . . . . . . . . . . . . . . . . 30.5
Manufacturing variation
Number of outlets tested . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Test pressure (bar) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.7
Test temperature (°C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
ec: variation between the nominal flow rate and the average flow rate (%) 2.43
Cv: manufacturing coefficient of variation
Cv value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.74
Results based on the Cemagref protocol . . . . . . . . . . . . . . . . . . . . . . Very good
Results based on the ISO protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Flow/pressure law
In the form of: q = kHx. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.380
Value of x . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.507
Results based on the Cemagref protocol . . . . . . . . . . . . . . . . . . . . . . .. . Tolerant
Pressure variation for a flow variation of 10% (mCE) . . . . . . . . . . . . . . . 1.38
Clogging . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Recommended filtration (micron) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Low sensitive
Manufacturer's comments
Ura-T-Pathfinder. 3000 Path. 06-06-30-340-3000
High flow available in 10, 20 and 30cm spacing. Available in 0.150, 0.200, 0.380mm wall thickness. (*) values changed (Cv and Ec).
--
Miguel Colino
Grupo Chamartin S.A., Spain
Mobile: +386 41 536 140