biomass gasification boiler for water
USD $1,000 - $10,000 /Set
Min.Order:1 Set
Henan Wanda Chemical Equipment Co., Ltd.
The automatic biomass gasification boiler for water
Boiler:
1. Gasification chamber with large capacity and unique structure design to make the fuel burning so complete that combustion efficiency can reach more 95%.
2. Feeding system adopts advanced screw rotation drive automatic feeding device, don't feed within 1~2 days after surge bin filled with fuel.
3. Ignition system adopted burning machine or heat wire automatic ignition that greatly reducing the labor intensity of workers.
4.It needn't a yearly check or professional stoker workers to operate.
5. The boiler is compact structure, small in size and installation is simple such as needn't to set up tall chimneys.
6. Be used galvanized processing,so the water in the boiler is cleanly and durable.
Fuel:
1. Using biomass fuel,that is the state suppote to promote energy conservation and renewable resources .
2.Biomass fuel from a number of sources such as straw,waste wood,sawdust etc.It can save the cost.
Applications:
1.Widely used in greenhouses heating for plants;
2.Mainly uesd for hot water, bath, heating and drying of hotels, guesthouses, sauna bath center, beauty salon, villas, factories, schools and institutions.
Technical Specifications:
| Items | CLHOS0.058 | CLHOS0.08 | CLHOS0.12 | CLHOS0.18 | CLHOS0.23 | CLHOS0.35 | CLHOS0.48 | CLHOS0.70 | CLHOS1.05 |
| Fixed calorific capacity(Kcal) | 5x104 | 7x104 | 10x104 | 15x104 | 20x104 | 30x104 | 40x104 | 60x104 | 90x104 |
| Rated working pressure(Mpa) | 0 | ||||||||
| Rated the return water temperature (°C) | 85/60 | ||||||||
| Thermal efficiency(%) | >=90 | ||||||||
| Water Output(L) | >=1000 | >=1500 | >=2200 | >=3300 | >=4000 | >=6000 | >=8000 | >=12000 | >=18000 |
| Refer The Warming Area(m2) | 400-500 | 500-700 | 700-1000 | 1000-1500 | 1500-2000 | 2000-3000 | 3000-4000 | 4000-5000 | 7000-8000 |
| Diameter of Water(mm) | 50 | 50 | 50 | 65 | 65 | 80 | 80 | 100 | 125 |
Power Consumption | Induced Draught System (Kw) | 0.37 | 0.37 | 0.37 | 0.37 | 0.55 | 0.55 | 0.75 | 1.1 | 2.2 |
Induced Draught System (Kw) | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | |
Feeding System(Kw) | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 1.1 | 1.1 | 1.5 | 1.5 | |
| Chimney Size (mm) | 140 | 140 | 140 | 140 | 202 | 202 | 240 | 260 | 260 |
Size | Light(mm) | 1000 | 1200 | 1300 | 1400 | 1500 | 1700 | 1800 | 2400 | 2600 |
Width(mm) | 550 | 550 | 650 | 750 | 850 | 1000 | 1100 | 1250 | 1500 | |
Height(mm) | 1080 | 1330 | 1410 | 1500 | 1600 | 1800 | 1950 | 2100 | 2500 | |
| Transportation Quantity(Kg) | 300 | 370 | 430 | 510 | 735 | 980 | 1520 | 1860 | 2350 |
| Fuel Consumption(Kg/h) | 10 | 15 | 20 | 31 | 42 | 60 | 80 | 120 | 200 |
| Storage Bin Capacity(Kg) | 100 | 100 | 200 | 200 | 300 | 300 | 400 | 500 | 800 |