Puxin chep and high quality Biogas flow meter
Negotiable /Set
Min.Order:1 Set
Shenzhen Puxin Technology Co., Ltd.
JBD series of the gas meter are applicable to man-made and natural gas, LPG, air, and other no corrosive gases. The technical parameters of product satisfy the “GB/T6968 -97 gas meter” requirements. The product is the ideal choice of the gas meter.
Features:
New design structure, advanced technology, convenient installation, accurate measurement.
The shell of JBD1. 6 - SA. JBD2. 5: SA gas flow meter is made of aluminium alloy by casting. It has a good looking appearance,reasonable and compact inside structure. The design is excellent. The product is precise with small loss of pressure in measurement, and reliable.
Main Technical Parameters
Model | JBD2.5-SA |
Accuracy | B level |
Nominal flow rate Q | 2.5 m3/h |
Maximum flow rate Qmax | 4 m3/h |
Minimum flow rate Qmin | 0.025 m3/h |
Maximum working pressure | 10 kpa |
Basic difference limit | When Qmin≤Q≤0.1Qmin ≤±3% When 0.1Qmax≤Q≤Qmax ≤±1.5% |
Pressure loss | In Qmax, ≤200Pa |
Air tightness | No leak under 10KPa |
Long term performance | Fit the Durability Test B Level Standards GB/T696B-1997 |
Work Temperature | -10- +40 °C ≤85%RB |
Gas meter joint thread | M30x2 |
Gas meter joint center distance | 130mm |
HS CODE: 90268000