vertical biomass steam boiler
USD $500 - $10,000 /Set
Min.Order:3 Sets
Henan Province Import & Export Co., Ltd.
Vertical Biomass Fired Steam Boiler
1. Vertical oil/gas fired fire tube steam boiler
2. Flow interrupters are set in the fire tube to slow down the rate of the mist flow and increase the heat efficiency.
3. The mist flows in the fire tube, compares with the LSS vertical flow through boiler, the LHS boilers have a large water capacity and have wide adoptability to the load.
4. An openable ash clean door is set at the bottom of the boiler. The top cover of the boiler can be opened for easy cleaning ash and prolong the endurance of the boiler.
5. China controller is employed for the boiler for making the safety is available, and lower the running cost to a great extent.
LHS oil (gas)-fired steam boiler parameter | ||||||||
Itemmodel | LHS0.1-0.4/0.7-Q.Y | LHS0.15-0.7-Q.Y | LHS0.2-0.4/0.7-Q.Y | LHS0.3-0.4/0.7-Q.Y | LHS0.5-0.4/0.7-Q.Y | LHS0.8-0.7/1.0-Q.Y | LHS1.0-0.7/1.0-Q.Y | |
rated heat capacity kw | 70 | 105 | 140 | 210 | 350 | 560 | 700 | |
rated capacity t/h | 0.1 | 0.15 | 0.2 | 0.3 | 0.5 | 0.8 | 1.0 | |
rated working pressure MPa | 0.4/0.7 | 0.7 | 0.4/0.7 | 0.4/0.7 | 0.4/0.7 | 0.7/1.0 | 0.7/1.0 | |
saturated steam temperature C | 152/170 | 170 | 152/170 | 152/170 | 152/170 | 170/184 | 170/184 | |
design heat efficiency % | >90 | >90 | >89 | >89 | >89 | >89 | >89 | |
heating area m2 | 2.65 | 4.9 | 5.08 | 8.2 | 12.7 | 18.4 | 23.1 | |
boiler water capacity L | 360 | 360 | 510 | 930 | 1040 | 1620 | 2760 | |
flue diameter mm | 160 | 250 | 250 | 250 | 300 | 400 | 350 | |
feed water diameter DN | 25 | 25 | 25 | 25 | 25 | 40 | 40 | |
main steam tube diameter DN | 25 | 40 | 40 | 40 | 50 | 50 | 65 | |
safety valve diameter DN | 40 | 40 | 40 | 40 | 40 | 2x40 | 2x40 | |
blowdown tube diameter DN | 40 | 40 | 40 | 40 | 40 | 40 | 40 | |
fuel consumption | light oil kg/h | 7.0 | 10.4 | 13.8 | 22.5 | 34.5 | 51.5 | 68.2 |
natural gas Nm3/h | 8.0 | 12.4 | 16.5 | 24.0 | 40.3 | 60.5 | 80.6 | |
liquid gas Nm3/h | 3.2 | 4.8 | 6.4 | 10.4 | 16.0 | 23.8 | 31.6 | |
coal gas Nm3/h | 18.0 | 27.9 | 37.4 | 54.0 | 90.7 | 136.0 | 178.2 | |
transportation weight kg | ≈400/420 | ≈550 | ≈600/700 | ≈1000/1050 | ≈1200 | ≈1800/2000 | ≈2600/2730 | |
outlook size | L mm | 800 | 900 | 1000 | 1200 | 1200 | 1430 | 1600 |
W mm | 750 | 850 | 960 | 1150 | 1150 | 1380 | 1550 | |
H mm | 1610 | 1620 | 1840 | 2080 | 2380 | 2600 | 2790 | |
Notes:This form only for your reference, if any changed, please refer to Ex-factory technical documents. |
style='background:white'>4. An openable ash clean door is set at the bottom of the boiler. The top cover of the boiler can be opened for easy cleaning ash and prolong the endurance of the boiler.
5. China controller is employed for the boiler for making the safety is available, and lower the running cost to a great extent.