high qualitystraw massive biomass pellet hot water boiler in china
USD $100 - $100,000 /Set
Min.Order:3 Sets
Henan Province Import & Export Co., Ltd.
Automatic biomass pellets hot water boiler
Home use,low ignition temp,high calorific value,low ash,high V.M.no coke,save energy
Automactic biomass pellets hot water boiler
E-1 STRUCTURE:4 furnaces,6 passes.
Technical advantage:
1,E-1 boiler is suitable for wood pellet,auxiliary fuel:wood mass,coal pieces,etc.
2,Heating efficiency:91.15%.(E-2 structure:3 furnace,4 passes).
3,Dust will be falled into inside ash bin automatcilly,nothing of the dust.
4,High temperature burning(900C-1005C),low outflow smoke temperature(107C-113C).
(E-2:high temp(900C-1005C),low temp(110c-125C)).
5,Feeding one time for 5-10 hours working(according to boiler model).
6,Fine appearance,beautiful,bright colours.
7,Two years’ trouble-free operation.
8,PLC control system for adjustment of burning speed,flame.Reduce the noise.
9,Operation cost analysis:normal boiler,RMB100,our boiler is only need RMB50.
10,Simple maintainance,don’t need to clean every day.Slagging/3days,clean ash/1-2 years.
11,Electric ignite,automatic device for saving the little fire,don’t need to ignite once again.
Remark:Straw pellet has sugar in it,it is easy to coke in high temperature.We have use the special burning technology,let the coking parts easy to move and ensure the burning fully.
Item(E-2) | CLHS-0.08 | CLHS-0.12 | CLHS-0.175 | CLHS-0.24 | CLHS-0.35 | CLHS-0.54 | ||||
Rated thermal power | 10000Kcal | 7 | 10 | 15 | 20 | 30 | 45 | |||
Working pressure | Mpa | Atmospheric pressure | ||||||||
Heating efficiency | % | 86% | ||||||||
Power | Air system | Kw | 0.75 | 0.75 | 1.5 | 1.5 | 2.2 | 3 | ||
Ignite system | Kw | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | |||
Diamter of flue tube | mm | 165 | 165 | 165 | 165 | 220 | 220 | |||
Biomass consumption | Kg/h | 13.3 | 19 | 28.5 | 38.1 | 54 | 81.5 | |||
Hopper capacity | Kg | 400 | 400 | 400 | 400 | 450 | 450 | |||
Heating area for room | m2 | 500-700 | 700-900 | 900-1400 | 1400-1800 | 1800-2700 | 2700-4000 | |||
Chamber heating area | m2 | 5.02 | 5.972 | 8.724 | 10.023 | 14.201 | 22.4 | |||
Hot water capacity | t/h | 1.65 | 2.2 | 3.25 | 4.8 | 6.8 | 11.8 | |||
Boiler water volume | m3 | 0.39 | 0.47 | 0.782 | 0.892 | 1.558 | 1.924 | |||
Continuous working time | H | 30.5 | 23.4 | 14.7 | 11 | 8 | 5.8 | |||
Boiler body weight | Kg | 405 | 465 | 630 | 830 | 1180 | 1450 | |||
Hopper weight | Kg | 55 | 55 | 55 | 55 | 55 | 55 | |||
Transport weight | Kg | 460 | 520 | 685 | 885 | 1235 | 1500 | |||
Packing | LxWxH | Mm | 1420*640 *1520 | 1495*690 *1580 | 1615*790 *1630 | 1860*890 *1810 | 2060*990 *1960 | 2280*1090 *2070 | ||
Installation | LxWxH | Mm | 2920*2640 *2520 | 2995*2690 *2580 | 3615*2790 *2630 | 3360*2890 *2810 | 3560*2990 *2960 | 3780*3090 *3070 | ||
Hopper | LxWxH | mm | 1000*570 *750 | 1000*570 *750 | 1000*570 *750 | 1000*570 *750 | 1000*570 *750 |