Fetal Monitor (FM-600P)

Fetal Monitor (FM-600P)

Negotiable /Set

Min.Order:1 Set

Supply Ability:
50 Set / Sets per Month
Port:
SHENZHEN
Payment Terms:
T/T Credit Card

Quick Details View All >

Type:
Ultrasonic Transducer
Place of Origin:
Guangdong, China
Model Number:
FM-600P

Xian Far East Import & Export Co., Ltd.

Business Type: Manufacturer,Trading Company
Shaanxi China
Main Products: household electrical appliances ,electronic and electrical products ,hardware and tools ,vehicle spare parts ,garments

Product Details

Features:

Safe:Ultrasound dosage is under 50% of the safe standard.

Standard configure:FHR,  TOCO,  Fetal Movement

Optional:single or twins

Tone: Quality  "Sanyo" speaker take more clear and loud sound.

Display:12.1 high-resolution color TFT LCD display, support plug-in large-screen CRT display;Rotable Screen,Can be Viewed from different direction

Patent:  Special fetus awaking function within FHR probe.

Save function: Dynamic save and display the Monitoring information within 48 hours

Operation: Linux operation system,stable,easy to operate.

Auto-monitoring: Automatic monitoring mode,parameters can be preset

Power: Built-in rechargable Li-ion Battery, AC-DC Power supply,without interruption  monitor

Protable:Small size, convenient for multi bed monitoring and outside diagnosing.

Network :Support the extension almost for 128 units central monitor system

Specification:

FHR

Ultrasound Probe:12pcs chip, Multi-wafer,wavebeam,high sensitive

Frequency:1MHz ±5%

Intensity: <3mW/sq.cm

FHR range: 30-240bpm

Resolution:1bpm

Accuracy:1bpm/± 1%

TOCO

TOCO range:0-100 (relative unit)

Resolution:1

Non-linear error:  5%

Fetal Movement: Button Hand Count( Automatic cumulative number of movements)

NIBP

Measurement: Units:mmHg/Kpa optional

Pressure:  A double security protection software and hardware

protection:A double security protection software and hardware

Work Mode:Auto,Manual

Measurement: 2-60 minutes set up

Survey: Systolic blood pressure:60-240 mmHg ; Average Blood Pressure:40-200 mmHg ; Diastolic Blood Pressure: 30-180mmHg

Resolution:1mmHg

Accuracy:3mmHg

Pulse rate:40-240bpm

SPO2

Range:70%-99%

Resolution:1%

Accuracy: 2 Effective digital

Pulse Rate:40-240bpm

RESP

Range: 40-240bpm

Range:30-300bpm

Accuracy:1bpm/ 1%

Choice:I II III aVR aVL aVF V

Scan Speed:12.5mm/s 25mm/s 50mm/s

Gain choice:x0.25 x0.5 x1 x2

Application:Diagnosis,Monitor,Surgery

RESP

Range:1-99rpm

Resolution:1rpm

Accuracy:2rpm

TEMP

Range: 26 - 45

Resolution: 0.1

Accuracy: 0.2%

Working enviroment

Relative: temperature: 5- 40

Atmospheric: pressure:(86-106)Kpa,32 - 45 ±0.1)

Printer: 50mm usual thermal paper,more economical

Contact Supplier

Mr. Kevin Du General Manager Chat Now
Telephone
86-29-84675238
Fax
86-29-84622567
Address
No.34 Hanchen Road,Xian-710077 Shaanxi