SHR Beauty Machine For IPL skin rejuvenation equipment with cheap price
SHR Beauty Machine For IPL skin rejuvenation equipment with cheap price
SHR Beauty Machine For IPL skin rejuvenation equipment with cheap price

SHR Beauty Machine For IPL skin rejuvenation equipment with cheap price

USD $1 - $3,300 /Set

Min.Order:1 Set

Supply Ability:
300 Set / Sets per Month
Port:
BEIJING
Payment Terms:
Credit Card PayPal

Quick Details View All >

Laser Type:
Other
Q-Switch:
No
Style:
Portable
Certification:
CE ,ISO, TUV
Place of Origin:
Beijing, China
Brand Name:
XYY

Beijing Xinyingyue Science And Technology Co., Ltd.

Business Type: Trading Company
Beijing China
Main Products: ipl ,e-light ,slimming machine ,q switch laser ,co2 laser

Product Details

Product Description

 

SHR Beauty Machine For IPL skin rejuvenation equipment with cheap price

 

SHR Beauty Machine For IPL skin rejuvenation equipment with cheap price

 

Applications of IPL hair removal:

 

1. Hair removal ( normal mode and SHR mode) : All kinds of skin types, and hair colors.

 

2. Skin tightening: Skin lifting, improve flexibility and skin tone condition, anti- aging.

 

3. Skin rejuvenation: Wrinkles reduction, freckles,skin whitening, shrink large pores.

 

4. Vascular: Red face, red nose, spider veins,vascular removal.

 

 

Technical parameter of elight machine

Wavelength

590nm/640nm-1200nm

Handpiece number

1 piece 

Spot size

12*30(mm) &15*50(mm)

Cooling system

semiconductor+air+water+cooling gel

IPL light energy

1-50(j/cm²) 

Pulse duration

1-10ms

Pulse NO.

1-6

SHR pulse duration

1-7ms

SHR frequency

1-10HZ

SHR energy

1-50J/CM2

Skin cooling

-4°c-10°c

Display

10.4″color touch screen

Output power

1500W

Voltage

110v,50hz or 220v,60hz

Machine Size

(L*W*H):42cm*38cm*90cm

Net weight

60kg

Gross weight

91kg

Package size

45cm*54cm*60cm

 

Working principle of IPL hair removal:

SHR- Super Hair Removal, it's a revolutionary technology of hair removal which is having a sweeping success. (adopt technology AFT, EDF).

 

SHR combines laser technology and the benefits of the pulsating light method achieving practically painless results.

 

SHR (Super Hair Removal ) is the advanced IPL mode. Its shots frequency can reach 10Hz per second, while traditional IPL's shots frequency is just 1Hz. You can just slide the SHR handle on skin quickly. We call this treatment method "IN-MONTION", means slide quickly on skin. It represents a breakthrough in permanent hair removal with light technology. The treatment is more pleasant than with the conventional systems and your skin is better protected.

 SHR Beauty Machine For IPL skin rejuvenation equipment with cheap price

Hair removal of OPT elight machine


1. Cut or shave hair to 1-2mm or ask patients to shave at home 2-3 days before treatment.
2. Clear treatment area.
3. Turn on machine,
1). Use SHR, adjust pulse width at 7ms, frequency 5HZ, energy 10J/cm2.
2). Use normal hair removal treatment, put the 640nm or 690nm filter into the slot, select
"hair removal",adjust the parameter, set it to ‘ready’ .
4. Put cooling gel on treatment area about 2mm.
5. Wear protect goggles for patient and operator.
6. Shot the treatment area, let the crystal tip to touch cooling gel, You are permitted to have
1/3 overlapping on treatment area.
7. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
   feel warm or hot, you may put ice bag on treatment area until heat disappear.
Skin rejuvenation

1. Clear treatment area.
2. Turn on machine ,put the 560nm filter into the slot, select "skin rejuvenation",adjust the
parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
   feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
   disappears.
Pigmentation Therapy

1. Clear treatment area.
2. Turn on machine ,put the 480nm or 530nm filter into the slot, select "pigmentation
therapy",adjust the parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
   refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.
Vascular Therapy

1. Clear treatment area.
2. Turn on machine ,put the 580nm filter into the slot, select "vascular therapy",adjust the
   parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
   refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.
Acne Therapy

1. Clear treatment area.
2. Turn on machine ,put the 430nm filter into the slot, select "acne therapy",adjust the
parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.
 
Wrinkle removal
 
1. Clear treatment area.
2. Turn on machine ,put the 580nm filter into the slot, select "wrinkle removal",adjust the
parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.

 

SHR Beauty Machine For IPL skin rejuvenation equipment with cheap price

 


 

Packaging & Shipping

 

Our Services

 SHR Beauty Machine For IPL skin rejuvenation equipment with cheap price

Company Information

 

Contact Supplier

Mr. Michael Chen Sales Manager Chat Now
Telephone
86-10-89292545
Mobile
13691043615
Fax
86-10-67222159
Address
Room 308,Building 3, POP Center,Xinghua Street,Daxing District Beijing

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Beauty & Personal Care > Beauty Equipment > Laser Beauty Equipment
Categories
Hi~