2.6MHZ Sun Damage Recovery Medical Erbium Co2 Fractional Salon And Ultrapulse Laser Skin Resurfacing Equipment 220V 22V 10600nm
USD $1 - $6,000 /Set
Min.Order:1 Set
Beijing POP IPL Technology Co., Ltd.
Fuctions and treatment effect of elight ipl rf
1.Permanent hair removal.
2.Smooth wrinkles, face-lifting
3.Deep flecks, epidermis flecks or pigment treating the telangiectasis
4.Promote collagen to grow, strengthen flexibility of skin
5.Acne treatment
6.Shrink the thick pore
7.For endogenous pigment: nevus of Ota, coffee spot, age pigment, freckle etc removal
8.For exogenous pigment: tattoo, eyeliner and eyebrow removal
9.Skin whitening
10.Striae gravidarum removal
Treatment theory
e-light beauty equipment CE beauty machine combines three advanced technologies:Bipolar Radio Frequency + IPL + Skin Contact Cooling
The working theory is heating the dermis to a target temperature gradually,at that target temperature, it damages the hair follicles and prevents re-growth effectively,meanwhile avoiding injury to the surrunding tissue.A high repetition rate of single pulses are delivered deep into the dermis,achieving high average power and therappeutically effectively heat bulit-up,without the risk of injury and no pain virtually.
Principle of RF CO2 Fractional Laser
CO2 Fractional Laser System fires a laser beam which is split into numbers of microscopic beams, producing tiny dot or fractional treatment zones within the selected target area only. Therefore, the heat of laser only passes deeply through the fractional damaged area. This allows the skin to heal much faster than if the whole area was treated. During the skin self-resurfacing, a great amount of collagen is produced for skin rejuvenation, eventually the skin will look much healthier and younger.
Introduction:
10.4 inch big color touch LDC screen RF Vaginal +fractional+Normal CO2
Applications:
Application:
1. Application Range of Fractional treatment handpiece
a. Large pores, Fine lines, Skin tightening and whitening, Skin loosen(Deep Wrinkles), Stretch marks.
b. Various Scars: Burn Scars, Acne Scars, Surgical Scars and Keloid;
c. Reconstruction of photoaging skin.
2. Application Range of Incision Handpiece
a. Via multiple handles it can be adapted to Gynecology, ENT, Neurology and general surgery
b. In cosmetic surgery, it can be adapted to incisions for Blephaplasty, Skin Tags and Ingrow Nails, Compound Nevus and Intra Dermal Nevus etc
1. Vaginal Tightening Laser
2. Fractional resurfacing CO2
Features& Advantages:
1. USA Coherent RF Excited CO2
2. 3 kinds of treatment mode
3. Adjustable scanning kinds of patterns and different sizes
4. Built-in blowing smoke system
5. Adjustable pulse duration
6. Automatic alarm Systems for operation and troubles
7. High return with no consumable costs
Specifications:
Wavelength: 10.6+ 0.1um
Beam Transmission System: 7-Articulation joint Spring-Balanced Light Guiding Arm.
Power:1--30W
The range of IPL treatment:
(1)Everlasting hair removal:remove unwanted hairs under arms,on legs ,lips or other body part,etc.
(2)Pigmentation treatment:remove various kinds of pigment such as freckle,chloasma,aged spots,sunburn,etc.
(3)Telangiectasis treatment:treat angiotelec-tasis.
(4)Acne treatment:papule,tuber,Blain,acne,etc.
(5)Shrink pores,tighten skin,improve skin elasticity and glossiness.
(6)Eliminate and smooth wrinkles,acne treatment.
CO2 laser system
The CO2 laser with a specific wavelength of 10.6 nm can be absorbed by human body tissue (no matter what color the skin is) by nearly 100%. Through laser emitter, the micropulsed laser beam shoots on the target skin in nanometer level to achieve a controllable precise treatment .The dimension of shooting area only can be measured in nanometer, which is precise enough for operators to control and adjust the treated depth andlayer according to the clinical diagnosis.
The energy of CO2 laser is even and steady. Its focused energy aims only at target tissue without any injury to surroundings. It is the heat and electromagnetic effect of the laser that people use to conduct non-blood or less-blood cutting, cauterizing, gasification and accurate microsurgery so as to avoid skin burnt. During the treatment, biochemical reactions of optical-thermal accelerate collagen reproduction and skin recovery,after exfoliation of the tiny scar; fresh and smooth skin can be regenerated. The device outputs invisible laser. In order to operate with more ease, red semiconductor laser has been added to indicate.
Operate Mode:Vaginal , Fractional and Ultra Pulse
Indication Beam : Green Semiconductor Laser(532nm,<5m W)
Operating Interface: 10.4" TFT color screen
Scanning area :Max20x20mm(HFLS)
Scanning patterns Number: 7 kinds
Scanning patterns Type:
Rectangular, Square, Ellipse, Circle, Rect, straight line, hexagon and triangle
Cooling Systems: Air cooling
Treatment theory:
The CO2 laser produces a beam of infrared light with the principal wavelength centering around 9.4 and 10.6 micrometers. With fractional laser resurfacing, the laser beam is broken up or fractionated into many small micro beams which are separated. These small areas of untreated skin promote a much more rapid recovery and healing with less risk of complications. The small areas treated by the fractional micro beams, called micro treatment zones, cause sufficient laser injury to promote new collagen production and resultant facial skin rejuvenation.
Main Technical Parameters:
Laser wavelength: 10.6µm
Laser unit:TEM00 module Co2 unit (best quality for the facula)
Output power: super pulse output 0.3-7W, peak value 450W,continuous output 0.3-25W
Laser output mode: continuous, single pulse, repeat pulse, super pulse, with the optional pixel laser handpiece for Pixel laser output mode
Conducting system: seven joints longer articulated arm(the most advanced conducting light system in the world and the only one in China). It could be operated in the scope of R=1.7m, which makes the operation more flexible
Handpiece:multiple function handpiece and two kinds of focus lens for f=100mm and f=50mm. With the optional adapter, it could be used for orthopedic, gynaecology and ENT surgery
Operation mode:controlled by a touch screen and with the engineer interface and the doctor interface
Min. spot diameter:≤0.1mm, variable spot adjusting handpiece:0.1-2.5mm
Pulse width: the minimum pulse width is 0.1ms
The RF equipment has the cooling system of surface layer, and uses proprietary technology
to deliver radiofrequency energy to the deep layers of the skin and its underlying tissue. The
heat will accelerate the blood circle, lets the fibre structure shrink instantaneously, and
stimulates the renewal of collagen. In response, the collagen shrinks and remodels over time,
providing you with tighter skin, renewed facial contours.