Laser Equipment CO2 Fractional/Fractional Co2 Mole Removal Laser Scar Removal Beauty Equipment 0.1-2.6mm
USD $6,000 - $12,500 /Unit
Min.Order:1 Unit
Xi'an Taibo Electronic Technology Co., Ltd.
Application:
1. Application Range of Fractional treatment handpiece
a. Large pores, Fine lines, Skin tightening and whitening, Skin loosen(Deep Wrinkles), Stretch marks.
b. Various Scars: Burn Scars, Acne Scars, Surgical Scars and Keloid;
c. Reconstruction of photoaging skin.
2. Application Range of Incision Handpiece
a. Via multiple handles it can be adapted to Gynecology, ENT, Neurology and general surgery
b. In cosmetic surgery, it can be adapted to incisions for Blephaplasty, Skin Tags and Ingrow Nails, Compound Nevus and Intra Dermal Nevus etc
Laser Equipment CO2 Fractional/Fractional co2 laser scar removal beauty equipment
Our Product Advantage:
1. RF Laser Tube is more stable than traditional Glass tube, the machine is non serviceable |
2. With the RF laser Tube, the scanning depth can reach the derma layer ,to accelerate the collagen re-growth. |
3. RF Laser Tube makes the scanning dot much thinner and less harm |
4. The Laser Tube frequency can reach more than 5000HZ, high scanner can get better treatment effect |
5. Four working modes ,Fractional, CW, Pulse, Ultra Pulse ,one machine can been used in widely in different surgery |
6. Special designed energy self-inspected and energy-replenishment system, improving the stability and effect |
7. Multi safety protection, water, electric ,remote interlock warning alarm |
8. Laser anti-leak designing, confirm the operator and client safety |
9. Whole low voltage system, no electric danger and no electric radiation |
The Machine Detailed Application:
Cosmetic Application | Rhytides (Wrinkles) | Medical Application | Actinic keratosis (sun-damaged skin, precancerous lesions) |
Mottled dyspigmentation | Seborrheic keratosis (sun-damaged skin, precancerous lesions) | ||
Telangiectasia (Red Spots) | Sebaceous hyperplasia (yellow, shiny bumps on the face) | ||
Solar lentignes (Brown spots) | Rhinophyma (nose swelling and tissue over growth | ||
Large pores,Rough skin texture | Epidermal Melasma (Brown spots) |
The All Detailed Specification:
Laser source | RF Laser Tube |
(Manufactured by Coherent America) | |
Working Mode | Fractional Mode |
Continuous Wave Mode (CW) | |
Pulse Mode (single and repeated) | |
Ultra Pulse Mode | |
Laser Wavelength | 10600nm |
Power of laser generator | Max 60W OUR VALUE MESSAGE IS “QUALITY IS OUR CULTURE” |
Output Power | 1-30W |
Focus Diameter | ≤0.1-1.2 mm |
Treatment Depth | Max 2mm |
Aiming Beam | Red Diode laser (650nm,≤5mW) |
Delivery System | 7-Articulation Joint Spring Arm |
Scanning Area | Max 20×20mm |
Scanning shape | Ellipse, Rectangular, Triangular, Line, Square, Hexagon |
Scanning mode | Sequence Mode |
Middle split Mode | |
Random Mode | |
Smoke Exhausting System | Built-in air blow |
Cooling system | Air Cooling |
Environmental temperature | 5°C~40°C |
Relative Humidity | ≤80% |
Power Supply | ~220V±22V,50Hz±1Hz |
Dimension | 450mm×550mm×1400mm |
Weight | 40kg |
Parameters:
Laser source | RF Laser Tube |
(Manufactured by Coherent America) | |
Working Mode | Fractional Mode |
Continuous Wave Mode (CW) | |
Pulse Mode (single and repeated) | |
Ultra Pulse Mode | |
Laser Wavelength | 10600nm |
Power of laser generator | Max 60W |
Output Power | 1-30W |
Focus Diameter | ≤0.1-1.2 mm |
Treatment Depth | Max 2mm |
Aiming Beam | Red Diode laser (650nm,≤5mW) |
Delivery System | 7-Articulation Joint Spring Arm |
Scanning Area | Max 20×20mm |
Scanning shape | Ellipse, Rectangular, Triangular, Line, Square, Hexagon |
Scanning mode | Sequence Mode |
Middle split Mode | |
Random Mode | |
Smoke Exhausting System | Built-in air blow |
Cooling system | Air Cooling |
Environmental temperature | 5°C~40°C |
Relative Humidity | ≤80% |
Power Supply | ~220V±22V,50Hz±1Hz |
Dimension | 450mm×550mm×1400mm |
Weight | 40kg |
Advantages of RF Co2 Fractional Laser:
1. RF Laser Tube is more stable than traditional Glass tube, the machine is non serviceable |
2. With the RF laser Tube, the scanning depth can reach the derma layer ,to accelerate the collagen re-growth. |
3. RF Laser Tube makes the scanning dot much thinner and less harm |
4. The Laser Tube frequency can reach more than 5000HZ, high scanner can get better treatment effect |
5. Four working modes ,Fractional, CW, Pulse, Ultra Pulse ,one machine can been used in widely in different surgery |
6. Special designed energy self-inspected and energy-replenishment system, improving the stability and effect |
7. Multi safety protection, water, electric ,remote interlock warning alarm |
8. Laser anti-leak designing, confirm the operator and client safety |
9. Whole low voltage system, no electric danger and no electric radiation |
Technology of Ultrapulse
Mainly let the original average output of the laser energy concentrated in a very short period of time then output, due to the high pulse power, short time, and more round spot, the pressure on the surface from laser heat transfer effects is low (small heat-affected zone).
The Machine Parts Detailed Specification:
Before and After Treatment Effect Photos:
Our Services:
1. Provide 2 year warranty
2. In two year, any problem, we will send spare parts to you by DHL. Provide video and
file for your reference
3. Our Alibaba account online for 24 hours. Our phone is open for 24 hours.
4. Provide OEM and ODM service. Can design according to your demands
Your satisfaction and good feedback is our service principle....
Our Factory Brief Details:
Our Factory Detailed Exhibition in World:
CO2 laser system
The CO2 laser with a specific wavelength of 10.6 nm can be absorbed by human body tissue (no matter what color the skin is) by nearly 100%. Through laser emitter, the micropulsed laser beam shoots on the target skin in nanometer level to achieve a controllable precise treatment .The dimension of shooting area only can be measured in nanometer, which is precise enough for operators to control and adjust the treated depth andlayer according to the clinical diagnosis.
The energy of CO2 laser is even and steady. Its focused energy aims only at target tissue without any injury to surroundings. It is the heat and electromagnetic effect of the laser that people use to conduct non-blood or less-blood cutting, cauterizing, gasification and accurate microsurgery so as to avoid skin burnt. During the treatment, biochemical reactions of optical-thermal accelerate collagen reproduction and skin recovery,after exfoliation of the tiny scar; fresh and smooth skin can be regenerated. The device outputs invisible laser. In order to operate with more ease, red semiconductor laser has been added to indicate.