Vertical medical long pulse laser 1064 and 532 for hair removal and vascular (Super Pulse)
Negotiable /Unit
Min.Order:1 Unit
Jiatailonghe (Beijing) Co., Ltd.
Vertical medical long pulse laser 1064 and 532 for hair removal and vascular (Super Pulse)
1. Introduction of the long pulse laser hair removal
In the 90s, safe and efficient removal of excess hair characteristics become the principal means.Vein in the leg, telangiectasia, vascular tumors and facial wrinkles is also troubled by long-term patients with the disease, however, the use of long- pulse laser can be good treatment of such dieases.
2. The best-wavelength laser
Laser hair removal must satisfy two important conditions. For the first: laser hair follicles have been able to fully absorb the organization. Second: the laser can effectively pass through the skin to reach the location of the hair follicle. Long-pulse laser's wavelength is 1064nm, it is a spectrum of near-infrared region, and better absorption of melanoma at the same time to penetrate the deep dermis and subcutaneous fatty tissue, in different parts of the role and depth of the hair follicle, effectively removing any parts of the human body and depth of the hair.
3. protect the normal skin while removing pigment diseases
Best result of hair removal connect with the pulse width and thickness of hair. Coarse hair the more necessary for the role of laser longer, the long-pulse laser pulse width is from 1 ms to 30 ms, It can obtain the desired effect of hair removal, At the same time, It can effectively protect the skin from heat damage.
It can effectively penetrate the hair follicle to the site, the wavelength of the laser is around 1064nm, in the near-infrared spectral region, the absorption of melanin in the hair follicle, resulting in selective destruction, so that the hair follicle degeneration, shrinking to the role of permanent hair removal And therefore the more coarse black hair and Vietnam, its hair follicles bigger, deeper melanoma, it's more acceptable to the laser damaging effects, the better it is, on the contrary more valuables hair color shallow consequential effects of the poor, white hair as a result of Hair follicle-free treatment of melanoma and therefore null and void.
4. No pigmentation of the most suitable for Asian skin
Laser through the skin on the role of the hair follicle, epidermal basal cell layer of melanin to absorb the laser energy produce inflammation, caused by postoperative skin pigmentation, which will last ten days pigmentation, would adversely affect the effect of beauty. Asians who belong to the non-ferrous Species, epidermal melanin content in larger, traditional IPL hair removal, which is particularly inflammatory. The long-pulse laser thermal relaxation of the use of pre-time effects in the role of the skin, can lower the energy output under the premise of hair to achieve the objective of long-pulsed laser deep penetration depth, the skin to absorb the laser energy rarely, so Pigmentation is not easy to present itself.
5. The effect of hair removal connect with the hair growth cycle
Hair growth is divided into three periods: growth, recessive, quiescent period. The different parts have different hair growth cycle. Recessive of the laser, hair quiescent no significant role in hair growth, and so only in order to play a role.In the treatment, hair growth in the proportion of the smaller, the number of treatment has to be more the other hand, growth in the proportion of more treatment, the better. If the scalp, beard, the upper lip hair growth in the proportion is 85%, 70%, 65%. And Ye Mao, bikini, only 30% growth in the chest, arms, legs hair growth in the proportion of smaller, representing only 20% per cent. This shows that the effects of good or bad hair, and hair growth cycle and the number of treatment and treatment related to the frequency.
6. Specification
Wavelength: 1064nm, 532nm (telangiectasia, the treatment of hemangiomas)
Energy density: 10-150J / cm2
Pulse width: 1-30ms
Pulse delay: 1-100ms
Pulse mode: a number of synchronization pulses
Repetition rate: 1Hz, 2Hz (can be adjusted to 2Hz when it’s low energy)
Spot size: 2-14mm, for the treatment of vascular spot diameter 6mm
7.Certification
ISO 9000, SFDA, CE