Hospital device 12.1" TFT display Ambulance multi parameter patient monitor
Hospital device 12.1" TFT display Ambulance multi parameter patient monitor
Hospital device 12.1" TFT display Ambulance multi parameter patient monitor
Hospital device 12.1" TFT display Ambulance multi parameter patient monitor
Hospital device 12.1" TFT display Ambulance multi parameter patient monitor

Hospital device 12.1" TFT display Ambulance multi parameter patient monitor

USD $400 - $500 /Set

Min.Order:1 Set

Supply Ability:
1000 Set / Sets per Month
Port:
Beijing or Tianjin
Payment Terms:
Credit Card

Quick Details View All >

Type:
Other
Brand Name:
Carejoy
Model Number:
RPM-9000A
Place of Origin:
Beijing, China

Beijing Carejoy Technology Co., Ltd.

Business Type: Trading Company
Beijing China
Main Products: Ultrasound Scanner ,Patient Monitor ,ECG Machine ,Pulse Oximeter ,Holter

Product Details

 

Hospital device 2.1" TFT display Ambulance multi parameter patient monitor

 

Features:   

  • Ergonomic design, portable, convenient for use
  • 12.1" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters
  • Unique digital SPO2 technology can work accurate during motion and low perfusion
  • Anti AC &high-frequency electrosurgical & defibrillators interference
  • Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others
  • Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
  • ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation
  • Audible & visual alarm available, adjustable
  • Patient information management function
  • Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room
  • Optional software upgrading based on USB
  • Wired/wireless networking with central monitoring system, up to 64 beds in one group
  • Built-in 3 trace thermal recorder for printing real-time and historical data
  • Multi-language i.e. English, Spanish, Turkish.
  • Super long life rechargeable Lithium battery upto 4 hours of working time

  • Suitable for adult, pediatrics and neonate patients

Standard configuration:            

Optional:            

Specification:

 

 

ECG

Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate: 
Scope: 15 times/minute to 300 times/minutes
Accuracy:  ±1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period. 
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.   
Accuracy: Error rate < 20%         
Undetected rate < 20% 
ST section 
Scope:     ±0.8mV
Precision : 
< ±0.05mV

SpO2

Detection scope:   0%-100%
Accuracy         ±1%     90%-100%               
                 ±2%      70%-89% 

NIBP 

Theory Electric oscillator 
Cuff gassing time   less than 15 seconds
First-time gassing pressure: dynamic state 24kPa
(180 mmHg)
Manual selection: 9.3kPa
(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)
18.6kPa
(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
Automatic detection period: 1 minute to 240 minutes 
Stop size
:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
in -90min) and 30min
(90 min -240min)
Detection scope: 
Systolic blood pressure:   4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure             2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure               2.7kPa
~31.3kPa       (20mmHg~235mmHg)
Detection accuracy 
Static pressure: ±3mmHg
Pulse rate:  ±2%

Resp

Chest impedance method or concentration of carbon dioxide at end of respiration 
Scope of chest impedance method     0 time/minute – 100 minutes/minute 
Precision of chest impedance method  time/minute 
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg
; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute
(including baby)
Detection precision of respiration rate: ±1 time/minute 

Temp

Single/double path 
Type:    Vascular/surface temperature 
Scope:    20
~50
Accuracy:  ±0.2

Invasive blood pressure (optional)

Single/double path 
Type: direct and continuous detection 
Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg)  13.33k
Pa(100mmHg) above ±2%
Frequency response
:DC-12Hz
Input resistance: not less than 500
Sensitivity of sensor: 5μV/V/mmHg
Motivation voltage
:5V (DC)
Accuracy of sensor: ±2
%Isolation voltage: 4 kV

 Hospital device 12.1" TFT display Ambulance multi parameter patient monitorHospital device 12.1" TFT display Ambulance multi parameter patient monitorHospital device 12.1" TFT display Ambulance multi parameter patient monitorHospital device 12.1" TFT display Ambulance multi parameter patient monitorHospital device 12.1" TFT display Ambulance multi parameter patient monitorHospital device 12.1" TFT display Ambulance multi parameter patient monitorHospital device 12.1" TFT display Ambulance multi parameter patient monitor

Company Information

Hospital device 12.1" TFT display Ambulance multi parameter patient monitorHospital device 12.1" TFT display Ambulance multi parameter patient monitor 

CE Certification

Hospital device 12.1" TFT display Ambulance multi parameter patient monitor 

Hot selling

Hospital device 12.1" TFT display Ambulance multi parameter patient monitor 

Contact information

Hospital device 12.1" TFT display Ambulance multi parameter patient monitor 

Contact Supplier

Ms. Frances Wang Sales Manager Chat Now
Telephone
0086-010-82125963
Mobile
0086-18101035075
Address
Suite302, No. 2 Building, Changping Road No. 97, Shahe, Changping Beijing

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Medical Devices > Emergency & Clinics Apparatus
Categories
Hi~