Product Details

Sanhe Beauty cosmetic surgery scar removal co2 laser

Laser Type Other, CO2 Laser, 10.6μm
Q-Switch No
Style Stationary
Certification CE
Place of Origin Beijing, China
Brand Name Sanhe
Model Number SC-2
Feature Acne Treatment, Blood Vessels Removal, Face Lift, Pigment Removal, Pigmentation Correctors, Pore Remover, Skin Tightening, Whitening, Wrinkle Remover, Other, Acne Treatment, Blood Vessels Removal, Face Lift, Pigment Removal, Pigmentation Correctors, Pore Remover, Skin Tightening, Whitening, Wrinkle Remover, Vaginal tightening

Product Features

SC-2 Metal RF CO2 Fractional Laser Skin Care Device

 

Sanhe Beauty cosmetic surgery scar removal co2 laser

 

Fractional resurfacing is a new laser treatment modality that creates numerous microscopic thermal injury zones of controlled width, depth, andd ensity that are surrounded by are servoir of spared epidermal and dermal tissue,all owing for rapid repair of laser-induced thermal injury.

 

  

Detail Application( Cosmetic and Medical Application):

 

Cosmetic ApplicationRhytides (Wrinkles)Medical ApplicationActinic keratosis (sun-damaged skin, precancerous lesions)
Mottled dyspigmentationSeborrheic keratosis (sun-damaged skin, precancerous lesions)
Telangiectasia (Red Spots)Sebaceous hyperplasia (yellow, shiny bumps on the face)
Solar lentignes (Brown spots)Rhinophyma (nose swelling and tissue over growth
Large pores,Rough skin textureEpidermal Melasma (Brown spots)

 

 

Specifications

 

Laser source
RF Laser Tube
(Manufactured by Coherent America)
Working Mode
Fractional Mode
Continuous Wave Mode (CW)
Pulse Mode (single and repeated)
Ultra Pulse Mode
Laser Wavelength
10600nm
Power of laser generator
Max 60W
Output Power
1-30W
Focus Diameter
≤0.1-1.2 mm
Treatment Depth
Max 2mm
Aiming Beam
Red Diode laser (650nm,≤5mW)
Delivery System
7-Articulation Joint Spring Arm
Scanning Area
Max 20×20mm
Scanning shape
Ellipse,
Rectangular,
Triangular,
Line
Square
hexagon
Smoke Exhausting System
Built-in air blow
Cooling system
Air Cooling
Environmental temperature
5°C~40°C
Relative Humidity
≤80%
Power Supply
~220V±22V,50Hz±1Hz
Dimension
450mm×550mm×1400mm
Weight
 40kg

 

 

 

 Advantage
  1. RF Laser Tube is more stable than traditional Glass tube, the machine is non serviceable.
  2. With the RF laser Tube, the scanning depth can reach the derma layer , to accelerate the collagen re-growth. 
  3. RF Laser Tube makes the scanning dot much thinner and less harm.
  4. The Laser Tube frequency can reach more than 5000HZ, high scanner can get better treatment effect.
  5. Four working modes ,Fractional, CW, Pulse, Ultra Pulse ,one machine can been used in widely in different surgery.
  6. Special designed energy self-inspected and energy-replenishment system ,improving the stability and effect.Multi safety protection,  water, electric ,remote interlock warning alarm.
  7. Laser anti-leak designing, confirm the operator and client safety.
  8. Whole low voltage system, no electric danger and no electric radiation.

 Pictures

 

 

 

Sanhe Beauty cosmetic surgery scar removal co2 laser

 

Sanhe Beauty cosmetic surgery scar removal co2 laser

 

Sanhe Beauty cosmetic surgery scar removal co2 laser

 

Sanhe Beauty cosmetic surgery scar removal co2 laserSanhe Beauty cosmetic surgery scar removal co2 laser

Sanhe Beauty cosmetic surgery scar removal co2 laser

 

 

Notice Before Treatment

  • The patient should not take any medications containing aspirin (acetyl salicylic acid), high doses of vitamin E,eating garlic,consuming alcohol and smoking at least 2 weeks before and after the treatment.
  • The surgeon will decide whether preliminary examination sare necessary,such as blood tests,an electrocardiogram,or x-ray sof the lungs.If this is the case,these tests should be performed 2weeks before the surgery.
  •  It is best not to wear any make up when the client comes in for the operation.
  • Wear loose clothing that doesn't need to be pulled over head; the client may also want to bring a scarf to cover the bandages on the way home.
  • Do not eat or drink anything for 6 hours before your operation.
  • Local anesthetic will be injected subcutaneously (under the skin).
 
 
Operation Procedure
  1. Clean the skin.
  2. About 20-30 minutes prior to treatment, apply a topical anesthetic to the treatment area.
  3. Right before treatment beginning, wash off the anesthetic and apply a thin layer of the tracking gel.
  4. Duringtreatment, apply cold air for patient comfort.
  5. After treatment, use our semi-conductor laser (physiotherapy laser) to enhance the patient’s treatment experience and accelerate the benefits of treatment.

 

 

Vaginal Treatment procedure

 

 

  1. Use the digital endoscope to detect the 1 condition of privates.
  2. Under the WIZ Scan Mode, insert the WIZ handpiece,Laser irradiation with 360-degreerevolution ,irradiating the laser Pulling out the handpiece by checking the scales on guide tip.
  3. Under the RF Scan Mode, put the Laser Irradiation on Target area , Rejuvenation and whitening.
  4.  
Sanhe Beauty cosmetic surgery scar removal co2 laser
 
 

 

Packaging & Shipping

 Sanhe Beauty cosmetic surgery scar removal co2 laser

 

Sanhe Beauty cosmetic surgery scar removal co2 laser

Our Services

 Sanhe Beauty cosmetic surgery scar removal co2 laser

 

 

Company Information

 Sanhe Beauty cosmetic surgery scar removal co2 laser

Sanhe Beauty cosmetic surgery scar removal co2 laser

Sanhe Beauty cosmetic surgery scar removal co2 laser

 

 

 

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now