Multifunctional Sanhe Beauty Equipment Gynecology Tumour Removal Video Colposcope Co2 Fractional Laser
USD $1 - $1 /Set
Min.Order:1 Set
Application:
1. Application Range of Fractional treatment handpiece
a. Large pores, Fine lines, Skin tightening and whitening, Skin loosen(Deep Wrinkles), Stretch marks.
b. Various Scars: Burn Scars, Acne Scars, Surgical Scars and Keloid;
c. Reconstruction of photoaging skin.
2. Application Range of Incision Handpiece
a. Via multiple handles it can be adapted to Gynecology, ENT, Neurology and general surgery
b. In cosmetic surgery, it can be adapted to incisions for Blephaplasty, Skin Tags and Ingrow Nails, Compound Nevus and Intra Dermal Nevus etc
Different types of laser tubes, USA Coherent RF Tube, China state-owned RF Tube, Glass Tube for your choice
co2 laser for vein removal
Main Function | Wrinkle, Scar, Vascular removal, Large Pores |
Object | Beauty Med Spa /Beauty Medical Spa |
Aesthetic Center |
Detail Application( Cosmetic and Medical Application):
Cosmetic Application | Rhytides (Wrinkles) | Medical Application | Actinic keratosis (sun-damaged skin, precancerous lesions) |
Mottled dyspigmentation | Seborrheic keratosis (sun-damaged skin, precancerous lesions) | ||
Telangiectasia (Red Spots) | Sebaceous hyperplasia (yellow, shiny bumps on the face) | ||
Solar lentignes (Brown spots) | Rhinophyma (nose swelling and tissue over growth | ||
Large pores,Rough skin texture | Epidermal Melasma (Brown spots) |
Introduction ( co2 laser for vein removal )
1. Fractional resurfacing is a new laser treatment modality that creates numerous microscopic thermal injury zones of controlled width, depth,and density that are surrounded by a reservoir of spared epidermal and dermal tissue,allowing for rapid repair of laser-induced thermal injury. This unique modality, if implemented with proper
laser-delivery systems, enables high-energy treatments while minimizing risks.
2. This machine use the RF Tube manufacturerd by Coherent America,the frequency can reach more than 5000HZ,the high speed can work more efficiecnt and effectively,it is very good for the ultra pulse incision for the precise surgey,no blood,the treatment area is very clear,andless down time.
The Advantage of the RF Tube Fractional laser
1. RF Laser generator is more stable than traditional glass tube ,it is dot need service
2. With the RF laser Tube,the scanning depth can reach the derma layer,to accelerate the collagen regrowth
3. RF Laser Tube makes the scanning dot much thinner and less harm
4. The Laser Tube frequency can reach more than 5000HZ,high speed scanner can get better treatment effect
5. The high frequency of the RF Tube make the machine reach the ultra pulse mode ,whole machine can use Fractional,CW,Pulse,Ultra Pulse,one machine can been used widely in different surgery
6. Special designed energy self-inspected and energy replenishment system,improving the stability and effect
7. Multi safety protection,water ,electric,remote interlock warning alarm
8. Laser anti-leak designing,confirm the operator and client safety
9. Whole low voltage system,no electric danger and no electric radiation
Specifications ( co2 laser for vein removal )
Laser source | RF Laser Tube (Manufactured by Coherent America) |
Working Mode | Fractional Mode Continuous Wave Mode (CW) Pulse Mode (single and repeated) Ultra Pulse Mode |
Laser Wavelength | 10600nm |
Power of laser generator | Max 60W |
Output Power | 1-30W |
Focus Diameter | ≤0.1-1.2 mm |
Treatment Depth | Max 2mm |
Aiming Beam | Red Diode laser (650nm,≤5mW) |
Delivery System | 7-Articulation Joint Spring Arm |
Scanning Area | Max 20×20mm |
Scanning shape | Ellipse, Rectangular, Triangular,Line Square,hexagon |
Scanning mode | Sequence Mode Middle split Mode Random Mode |
Smoke Exhausting System | Built-in air blow |
Cooling system | Air Cooling |
Environmental temperature | 5°C~40°C |
Relative Humidity | ≤80% |
Power Supply | ~220V±22V,50Hz±1Hz |
Dimension | 450mm×550mm×1400mm |
Weight | 40kg |
Two Treatment Heads(100mm and 50mm)
Scanner Head: 100mm diameter (Scanning Size: Maximum 20*20mm)
Cutting Surgery Head: 100mm diameter
Scanner Head: 100mm diameter (Scanning Size: Maximum 20*20mm)
Cutting Surgery Head: 100mm diameter
Optional head: vaginal head
Laser source | RF Laser Tube |
(Manufactured by Coherent America) | |
Working Mode | Fractional Mode |
Continuous Wave Mode (CW) | |
Pulse Mode (single and repeated) | |
Ultra Pulse Mode | |
Laser Wavelength | 10600nm |
Power of laser generator | Max 60W |
Output Power | 1-30W |
Focus Diameter | ≤0.1-1.2 mm |
Treatment Depth | Max 2mm |
Aiming Beam | Red Diode laser (650nm,≤5mW) |
Delivery System | 7-Articulation Joint Spring Arm |
Scanning Area | Max 20×20mm |
Scanning shape | Ellipse, Rectangular, Triangular, Line, Square, Hexagon |
Scanning mode | Sequence Mode |
Middle split Mode | |
Random Mode | |
Smoke Exhausting System | Built-in air blow |
Cooling system | Air Cooling |
Environmental temperature | 5°C~40°C |
Relative Humidity | ≤80% |
Power Supply | ~220V±22V,50Hz±1Hz |
Dimension | 450mm×550mm×1400mm |
Weight | 40kg |
Technology of Ultrapulse
Mainly let the original average output of the laser energy concentrated in a very short period of time then output, due to the high pulse power, short time, and more round spot, the pressure on the surface from laser heat transfer effects is low (small heat-affected zone).
Operation interface ( co2 laser for vein removal )
Factory Photos of SC-2 Fractional CO2 laser:
USA RF tube Report of SC-2 Fractional CO2 laser:
Effect of SC-2 Fractional Co2 Laser:
Package of SC-2 Fractional Co2 Laser :
Factory Imagine
Any question, please contact me:
Nicky
email: market36(@)
number: 0086-158-1124-8155(using whatsapp and viber, wechat)
facebook: /sanhenicky
Theory - co2 fractional laser