100J Best Slimming Products Weight Loss Bipolar Rf Ultrasonic Liposuction Cavitation BM807 Cavitation Rf Slimming Beauty Machine
USD $498 - $598 /Set
Min.Order:1 Set
Beijing Quartuslaser Technology Co., Ltd.
Vacuum Bipolar RF
For body and face re-shaping. Weight loss Vaccum+RF fat-explosion function can promote tissue metabolism,repel the cellulite, which make fat granule in different depths and shocking make fusion energy, and the deepest receptor can get granule in 3CM thick of skin, and rapid expansion and the rapid heating of the cell wall that exceed the elastic limits and arises cells broken, so that the combustion of fatty acids at the same time broken out of a pot, not only the burning consumption of fatty acids but also more directly emptying so rapidly reduce the size of granule.
CAVITATION +VACUUM+LASER MULTIPOLE RF SLIMMING SYSTEM
Technical Parameters
Energy output :56 x 180mW
Mains power output: 100VA
Safety :On board diagnostics
Classification :Electrical Class 1, Type B applied part
Cooling requirements :Air cooled
Mode of operation:Continuous
Wave fat system
With collective strong sound wave head, strong sound wave of 40KHZ may be emitted to vibrate fat cells at top speed and produce numerous vacuum air pockets inside and outside the fat cells, robustly impact fat cells to generate introverted blast and disintegrate triglyceride into glycerol and free fatty acids. Then RF waves at frequency of 1M HZ is used for exhausting the integrated glycerol and free fatty acids through hepatoenteral circulation. Finally, vacuum RF and energy electrode are used for positioning and tightening fat. In physics, it is known as "cavitation". Micropore introverted blast inside and outside cell may lead to enhanced molecular motion and a higher energy level and this will finally cause fat cell rupture and thereby achieve the effects of body building and losing weight.
Control Panel:
Advantage
1 Safe, minimally-invasive procedure,it uses low levels of visible red laser light to create a safe and painless stimulation is of the normal chemical pathways to free up reserved energy resources stored in fat.it is safe, effective and immediately demonstrable.
2 Easy to operate, treatments are passive and require only the correct positioning of treatment pads, it will not compromise office staff time or productivity,won't effect life and work after treatment,fast healing time
3 Treat All Skin Types,Treat All Body Parts such as neck, breasts, back, knees, hips, thighs, bottom and arms
4 Accelerate tissue coagulation to avoid muscle slack after slimming
5 No bleeding,no pain ,no side-effect
6 Save money, fast return on your investment
Instrument Function--Multi handles
Caution for using
RF radio frequency slimming machine is applied to:
Sculpture
Fat removal
Radio frequency slimming
Make the pores contracted
Increase blood circulation
Face lifting
Improve lymph drainage
1. Beautician should wear insulated gloves during operation.
2. Do not wear any aglet, both for the beautician and the users.
3. The electrode probe must be fully in contact with skin.
4. Do not make the RF electrode stay on any part without moving. Keep it moving on skin slowly.
5. Skin around eyes and forehead is very thin, the RF output intensity should be relatively weakened.
How does RF works?
The multi-polar radio frequency causes a reaction in the tissue which stimulates the body's natural healing response causing new collagen to form, and the production of new elastin fibres making skin to look and feel firmer.
Skin is heated consistently and uniformly without the risk of any burns.
How does Vacuum works?
After break up the subcutaneous fat, decrease cellulite accumulation. It helps smooth lymph and discharges the fatty acid and toxin that is decomposed through lymph system.
Vacuum hads immediate effect in body shaping.
6. Do not contact skin with unipolar when using of bipolar, tripolar,hexpolar RF work head otherwise it will produce pulse discharge, gel paste etc. Products like gel maybe evaporated into a mist.
NOTICE
1. Be sure to use the special ultrasonic gel.
2. Avoid knocking the us head.
3. For avoiding burning the head, during operation, please prepare enough ultrasoinc gel.
4. Don’t stay in one place, avoid treating on the bone.
5. Don’t use disinfectant product to disinfect the us head. We suggest the wet cotton or dry towel enough.
6. Check the machine power cord if it is connected well.
7. If the machine will not use for a loing time, please switch off it, and power off.
8. Please take off all metal decoration from the operator and patient’s body.
9. If continuous using 1 hour, please pause the machine about 10 minutes, then using again.
10.During the operation, be sure not to accept other treatment.
Treatment Compare:
1.Your inquiry related to our products or prices will be replied in 24 hrs.
2.Well-trained and experienced staffs to answer all your inquires in fluent English
3.OEM&ODM, any your customized products we can help you to design.
4.Distributorship are offered for your unique design and some our current models
5.Protection of your sales area, ideas of design and all your private information
: +86 15030797471 Want more information or video?
:qts_bonita AT Contact me without hesitate:)
3290173299 AT
:qts_bonita AT
Technology Explanation
High Intensity Focused Ultrasound penetrates focused and volumetric ultrasonic energy at precise depth (1.2 cm) in subcutaneous fat layers targeting fat tissue causing a non-thermal effect. The surrounding structures such as the epidermis, blood vessels and nerves will not be damaged. Meanwhile the metabolized contents (triglyceride, fatty acid) of cells will excrete outside body automatically through blood circulation and lymphatic drainage without harm to the human body.