New Style CO2 Laser Beauty Equipment
USD $9,215 - $13,981 /Set
Min.Order:1 Set
Beijing Quartuslaser Technology Co., Ltd.
CO2 Fractional Laser
The role of Principle
Fractional laser effect principle is "focal photothermal effect ". Skin tissue has ability to repair itself. The skin was injury by trauma, but it could heal itself. The wound area is too large, the results of repair of scar formation. The wound is small, the skin can completely recover. Fractional laser every effect to skin only on one of the small region to generate thermal stimulation, retaining portion of skin is not affected, the role of tissue to the skin to stimulate collagen receipt hyperplasia, and no effect of skin tissue can be used as thermal diffusion region, avoid the possibility of thermal injury and other side effects, and can quickly promote skin healing, reach, and improve scars, skin firming pores purpose.
Fanctional laser probe Pixel laser probe
Treatment range
Perfect skinwhiteningwrinkle removal acne preventionfacial beauty for human tissue burningvaporization and coagulation. Mainly used for local and facial skin, repair skin light aging, improve uneven skin, large pores, rough skin, the skin relaxation phenomena, especially applicable to dispel various scars and wrinkles, acne, tattoo, stains, and pigmentation, as well as on the surface of any part of a variety of moles, warts, acne, skin tag, treatment of hemangioma.
Technical parameters
Laser wavelength | 10.6 μm ± 0.1μ M |
Three output mode | Ultra pulse, continuous output and dot matrix output |
The output terminal of power | 1~30W |
Lattice point output energy of each | 5mj-100mj ( 16 speed adjustable ) |
Fractional output total energy | 125mj+1kj |
Scanner focal length | f=50mm ( FFLS ) or f=100mm ( HFLS ) |
Focal spot diameter | ≤ 0.1mm≤ 0.2mm ( FFLS ), ( HFLS ) |
Treatment of depth | 2000μ m ( FFLS ), 600 μ m ( HFLS ) |
Guidelines for glory | Green semiconductor laser ( 532nm,≤ 5mW ) |
System control | microcomputer control |
Exhaust system | built-in smoke system |
Cooling system | built-in closed water cooling circulation system |
Display | interface ( 10.4 inch color touch screen ) |
Light guide system | 2 joint torsion spring joint arm ( export) |
Way of working | galvanometer scanning ( lattice ): |
FFLS scan size | a maximum of 15*15mm |
HFLS scan size | a maximum of 20*20mm |
The oval, triangular (standard and adjustable ) | |
Scan rate | >10m/s continuous: 1~30W, every step 1W adjustable; |
Pulse frequency modulation Pulse frequency modulation | 0-999Hz, every step 1Hz adjustable |
Environment temperature | 5~40 degree |
Relative humidity | ≤ 80% |
Power supply | 220V, 50Hz, 3A |
Dimensions | 450mm 550mm 1400mm |
Weight | 40kg |
Scanning pattern | rectangle, square, triangle, circle, ellipse, straight line |
Pulse interval | 0-5000ms, every step 1ms adjustable |
Curative effect contrast