480-1200nm High Power Co2 Fractional Laser Carboxytherapy Vaginal 640-1200nm Treatment Beauty Salon Laser Equipment Acne Scar Removal
USD $1 - $50,000 /Set
Min.Order:1 Set
Beijing Quartuslaser Technology Co., Ltd.
The range of IPL treatment:
(1)Everlasting hair removal:remove unwanted hairs under arms,on legs ,lips or other body part,etc.
(2)Pigmentation treatment:remove various kinds of pigment such as freckle,chloasma,aged spots,sunburn,etc.
(3)Telangiectasis treatment:treat angiotelec-tasis.
(4)Acne treatment:papule,tuber,Blain,acne,etc.
(5)Shrink pores,tighten skin,improve skin elasticity and glossiness.
(6)Eliminate and smooth wrinkles,acne treatment.
Principle of RF CO2 Fractional Laser
CO2 Fractional Laser System fires a laser beam which is split into numbers of microscopic beams, producing tiny dot or fractional treatment zones within the selected target area only. Therefore, the heat of laser only passes deeply through the fractional damaged area. This allows the skin to heal much faster than if the whole area was treated. During the skin self-resurfacing, a great amount of collagen is produced for skin rejuvenation, eventually the skin will look much healthier and younger.
60w Fractional Co2 Laser Vaginal Rejuvenation beauty Equipment
Fractional Co2 Treatment Principle
CO2 fractional laser effect principle is "focal photothermal effect ". Skin tissue has ability to repair itself. The skin was injury by trauma, but it could heal itself. The wound area is too large, the results of repair of scar formation. The wound is small, the skin can completely recover. Fractional laser every effect to skin only on one of the small region to generate thermal stimulation, retaining portion of skin is not affected, the role of tissue to the skin to stimulate collagen receipt hyperplasia, and no effect of skin tissue can be used as thermal diffusion region, avoid the possibility of thermal injury and other side effects, and can quickly promote skin healing, reach, and improve scars, skin firming pores purpose. vaginal tightening vaginal rejuvenation urinary
Vaginal Treatment Principle
Use an articulate arm probe with automatically 3600 rotation technology, producing in 50-70oC at a controlled depth inside the vaginal mucosa - stimulates collagen contraction, restructuring and regeneration; promotes collagen fiber proliferating, remodeling; improves vaginal mucosa microcirculation; increases cell secretion and dynamic reaction function; corrects PH value of vaginal inside; improves the inside environment; achieve female private parts to significant lasting firming, nourishing and restoring harmonious sexual life.
Treatment range:
Fractional system
Collagen contraction and remolding; Skin tightening and lifting; Pore minimizes; Pigmentation & age spots removal; To treat photo aged skin and fine lines; To treat scars – chicken pox, post acne, post traumatic scars; Eliminates dead cells from the epidermis; Improve skin texture & skin tone Vulva rejuvenation, restoration girlish pink;
Normal System
used for cutting during the operation
Vaginal laser system
Tighten vagina - Improve the loose situation, make the vaginal canal smaller; Clean the vagina - female private parts maintenance; Moist vagina - eliminate dryness; vaginal tightening, vaginal rejuvenation, vaginal pink
Advantages
I .Vaginal Tightening: rapid tightening, lasting constriction firmness increase 60%.
II. Vaginal Beautify: Dilute pigment, the labia pink increase 70%.
III.Vaginalmoisten: increase secretion, eliminate dryness, lubricationincrease 80 percent.
IV.Vaginal Young Maintain: Deep anti-aging, youth increase 80%.
Headpiece
Laser wavelength | 10.6 μm ± 0.1μ M |
Three output mode | Ultra pulse, continuous output and dot matrix output |
The output terminal of power | 1~60W |
Lattice point output energy of each | 5mj-100mj ( 16 speed adjustable ) |
Fractional output total energy | 125mj+1kj |
Scanner focal length | f=50mm ( FFLS ) or f=100mm ( HFLS ) |
Focal spot diameter | ≤ 0.1mm≤ 0.2mm ( FFLS ), ( HFLS ) |
Treatment of depth Main Technical Parameters: Laser wavelength: 10.6µm Laser unit:TEM00 module Co2 unit (best quality for the facula) Output power: super pulse output 0.3-7W, peak value 450W,continuous output 0.3-25W Laser output mode: continuous, single pulse, repeat pulse, super pulse, with the optional pixel laser handpiece for Pixel laser output mode Conducting system: seven joints longer articulated arm(the most advanced conducting light system in the world and the only one in China). It could be operated in the scope of R=1.7m, which makes the operation more flexible Handpiece:multiple function handpiece and two kinds of focus lens for f=100mm and f=50mm. With the optional adapter, it could be used for orthopedic, gynaecology and ENT surgery Operation mode:controlled by a touch screen and with the engineer interface and the doctor interface The RF equipment has the cooling system of surface layer, and uses proprietary technology to deliver radiofrequency energy to the deep layers of the skin and its underlying tissue. The heat will accelerate the blood circle, lets the fibre structure shrink instantaneously, and stimulates the renewal of collagen. In response, the collagen shrinks and remodels over time, providing you with tighter skin, renewed facial contours. Min. spot diameter:≤0.1mm, variable spot adjusting handpiece:0.1-2.5mm Pulse width: the minimum pulse width is 0.1ms | 2000μ m ( FFLS ), 600 μ m ( HFLS ) |
Guidelines for glory | Green semiconductor laser ( 532nm,≤ 5mW ) |
System control | microcomputer control |
Exhaust system | built-in smoke system |
Cooling system | built-in closed water cooling circulation system |
Display | interface ( 10.4 inch color touch screen ) |
Light guide system | 2 joint torsion spring joint arm ( export) |
Way of working | galvanometer scanning ( lattice ): |
FFLS scan size | a maximum of 15*15mm |
HFLS scan size | a maximum of 20*20mm |
The oval, triangular (standard and adjustable ) | |
Scan rate | >10m/s continuous: 1~30W, every step 1W adjustable; |
Pulse frequency modulation Pulse frequency modulation | 0-999Hz, every step 1Hz adjustable |
Environment temperature | 5~40 degree |
Relative humidity | ≤ 80% |
Power supply | 110V-220V, 50Hz, 3A |
Dimensions | 500mm 650mm 1100mm |
Weight | 50kg |
Scanning pattern | rectangle, square, triangle, circle, ellipse, straight line |
Pulse interval | 0-5000ms, every step 1ms adjustable |
LCD | 8/10.4 |
RF fractional tube
Vaginal Rejuvenation Effects
Note:
Payment: T/T 100% in advance (Western Union or PAYPAL are welcomed)
Production lead time: 10-50 units: 5-10 days, 50~100 units:10-15 days, above 100 units: 15-20 days.
Sample can be delivered in 3 days
Shipping freight are quoted under your requests
Shipping port: Tianjin, Mainland China
Discounts are offered based on order quantities.
Fuctions and treatment effect of elight ipl rf
1.Permanent hair removal.
2.Smooth wrinkles, face-lifting
3.Deep flecks, epidermis flecks or pigment treating the telangiectasis
4.Promote collagen to grow, strengthen flexibility of skin
5.Acne treatment
6.Shrink the thick pore
7.For endogenous pigment: nevus of Ota, coffee spot, age pigment, freckle etc removal
8.For exogenous pigment: tattoo, eyeliner and eyebrow removal
9.Skin whitening
10.Striae gravidarum removal
CO2 laser system
The CO2 laser with a specific wavelength of 10.6 nm can be absorbed by human body tissue (no matter what color the skin is) by nearly 100%. Through laser emitter, the micropulsed laser beam shoots on the target skin in nanometer level to achieve a controllable precise treatment .The dimension of shooting area only can be measured in nanometer, which is precise enough for operators to control and adjust the treated depth andlayer according to the clinical diagnosis.
The energy of CO2 laser is even and steady. Its focused energy aims only at target tissue without any injury to surroundings. It is the heat and electromagnetic effect of the laser that people use to conduct non-blood or less-blood cutting, cauterizing, gasification and accurate microsurgery so as to avoid skin burnt. During the treatment, biochemical reactions of optical-thermal accelerate collagen reproduction and skin recovery,after exfoliation of the tiny scar; fresh and smooth skin can be regenerated. The device outputs invisible laser. In order to operate with more ease, red semiconductor laser has been added to indicate.
Treatment theory
e-light beauty equipment CE beauty machine combines three advanced technologies:Bipolar Radio Frequency + IPL + Skin Contact Cooling
The working theory is heating the dermis to a target temperature gradually,at that target temperature, it damages the hair follicles and prevents re-growth effectively,meanwhile avoiding injury to the surrunding tissue.A high repetition rate of single pulses are delivered deep into the dermis,achieving high average power and therappeutically effectively heat bulit-up,without the risk of injury and no pain virtually.