65% of buyers to choose!!!vascular removal equipment/Beauty parlour recommends
therapeutic machine treatment principle
It takes advantage of micro-point high-frequency lightning to Hz 13 million ultra-high-frequency electromagnetic oscillations, with unique soft silk (thinner than human hair), crushed hemoglobin within 1/100 second time, the energy released by conduction to the skin below the surface of removal of lesions capillaries, and intravascular hemoglobin crushed it into small molecules to be absorbed by the skin tissue to reach the one-time permanent eradication of red blood effect, each time treatment of red blood should not exceed 15 minutes, precise digital control system, perfect and simple treatment procedures, simple operation beneficial to quickly grasp.
Second, the installation Notes
a.The instrument should be placed smoothly in a clean operating room or treatment room with a room temperature of-10-40 degrees and humidity less than 60%. Otherwise some of the parts will be damaged and can never been repaired.
b.The installation of Foot switch
Insert the plug of foot switch directly into the interface of the foot switch of instrument, and tighten the screwed retaining ring in clockwise.( attention: during the tightening process, you should tightening as you insert the plug, until you can't tighten and insert any more, in case of virtual connection.)
c.power connection
Insert one end (the end connects the instrument) of the power cable directly into the instrument interface of 220V10A50HZ.
d.The connection of treatment head
Insert the end of treatment head which connects the instrument directly into the interface of high frequency base of instrument and tighten in clockwise, and confirm the installation is firm, in case of virtual connection.
e.Power on
Press the shift knob to the instate of "on". Then the instrument will power on and begin to work.
Instrument parameters
Input power | 70W |
Output power | 50W |
Output voltage | AC 90V-240V |
Output frequency | 24.50MHz |
Work mode | CW and pulse |
Treatment of needle wire | 0.01mm (Diameter) |
Steries needles Specification | 0.16/0.18/0.20*7mm |
Output mode | Continuous and pulsed two modes |
Hand length | 1.5m |
Stand-by working | Continuously for 24hours |
Temperature | 25-45℃ |
Liquid crystal display | 4.5 Inch |
Operating mode | Colour Touch |
Power | AC 110V/230V±10% 50Hz |
Dimensions | 45.5 X 46 X 41CM |
Net weight | 12kg |
How to use and operate the instrument
1) Installation Notes
a.The instrument should be placed smoothly in a clean operating room or treatment room with a room temperature of 20-45 degrees and humidity less than 60%. Otherwise some of the parts will be damaged and can never been repaired.
b.The installation of Foot switch: Insert the plug of foot switch directly into the interface of the foot switch of instrument, and tighten the screwed retaining ring in clockwise.( Attention: During the tightening process, you should tightening as you insert the plug, until you can't tighten and insert any more, in case of virtual connection.)
c.Power connection: Insert one end (the end connects the instrument) of the power cable directly into the instrument interface.
d.The connection of treatment head: Insert the end of treatment head which connects the instrument directly into the interface of high frequency base of instrument and tighten in clockwise, and confirm the installation is firm, in case of virtual connection.
e. The connection of earth wire:Wind one end of the yellow with green wire on the socket,the other end should connect with one metal material,like a screw,and let it touch the ground.
2) Operation Notes
(1)Press the shift knob to the instate of "on". Then the instrument will power on.
Step 1 : Choose the language to operate.
Step 2: Choose the treatment projection
Step 3:
The Pouch/BlackHead/Acne Rosacea Removal can treat the function as :Pouch,Blackhead and Acne Rosacea.
Energy suggestion: begin at 1 J/CM2, the highest one is : 15 J/cm2
Pulse Width : 10 (The number grow as the energy grow)
Spacing: 10 (The number grow as the energy grow)
The Vascular Veins Removal
Energy suggestion: begin at 5 J/cm2, the highest one stop at 10J/cm2.
For big vascular removal, suggest begin use the energy between 10-12 J/cm2.
Attention:
1. Use the pedal after the needles go thought the skin.
2. keep needles 90°treatment. Only needle tip touch skin.
3. Stop 2-3 seconds in the skin.