Treat Telangiectasis High Quality 100um-2000um Fractional CO2 Laser Medical Equipment
USD $1 - $1 /Set
Min.Order:1 Set
Beijing Metos Technology Co., Ltd.
Application:
1. Application Range of Fractional treatment handpiece
a. Large pores, Fine lines, Skin tightening and whitening, Skin loosen(Deep Wrinkles), Stretch marks.
b. Various Scars: Burn Scars, Acne Scars, Surgical Scars and Keloid;
c. Reconstruction of photoaging skin.
2. Application Range of Incision Handpiece
a. Via multiple handles it can be adapted to Gynecology, ENT, Neurology and general surgery
b. In cosmetic surgery, it can be adapted to incisions for Blephaplasty, Skin Tags and Ingrow Nails, Compound Nevus and Intra Dermal Nevus etc
High quality fractional CO2 laser medical equipment
Model #: MES-300
How it works?
CO2 Fractional Laser System fires a laser beam which is split into numbers of microscopic beams, producing tiny dot or fractional treatment zones within the selected target area only. Therefore, the heat of laser only passes deeply through the fractional damaged area. This allows the skin to heal much faster than if the whole area was treated. During the skin self-resurfacing, a great amount of collagen is produced for skin rejuvenation, eventually the skin will look much healthier and younger.
Is Fractional CO2 laser treatments safe to treat acne scars in darker skin types?
Dr. Schweiger safely treats acne scars in patients with all skin types including Asian, Indian, and African-American skin. An experienced laser surgeon is needed to treat darker skin types safely.
What is the downtime for this laser treatment?
The fractional CO2 laser causes a wound in the skin which means you will have three to four days of downtime when the skin is healing. During that time you have to apply an ointment frequently to your face keep the skin greasy, which makes healing faster.
What are the side effects of Fractional CO2 resurfacing?
The main risks are temporary or long-lasting light or dark spots from treatment. Very rarely scarring can still result. For these reasons it is important to be treated by an experienced laser surgeon.
What type of anesthesia is used during the procedure?
The whole procedure is done under local or topical anesthesia. You are awake and comfortable the entire time. Prior to the procedure, topical numbing cream is applied for 60-90 minutes. In addition, valium is given prior to the procedure to facilitate relaxation. Using these measures there is usually minimal discomfort during the resurfacing procedure.
Applications:
Skin renewing and resurfacing
Wrinkle removal, skin tightening
Acne and acne scar removal
Smooth burnt scars and surgery scars, etc
Remove intractable chloasmas and pigmentation
Sun damage recovery.
Advantages:
1. It will have thermal shock on a small area of skin and retain that portial skin is not affected
2. The fractional laser can remove the stain of the skin to stimulate the hyperplasia of collagen
3. Without effecting to the skin organizations as the thermal diffusion region to avoid any possible heat injury and to promote the healing of skin
4. A few days after collagen hyperplasia of micro-heating area appear micro-callus exfoliation, the effects of treatment maintained over the years
5. Operate easily, pain is minor, non-bleeding, no side effects, short recovery period
6. Shorter treatment time, non-chromatosis and no pigment miss out, no additional consumables
7. Cover area of 20% every treatment, total 4-6 times treatment, interval 3-4 weeks.
Specifications:
wavelength | 10.6μm, far-infrared laser |
Pulsed radiofrequency | 0.530 W |
Hyper-pulse | 1.Max power: 120W 2.Pulse width:200 to 500μs is optional |
Pulse | 1. Average power: 0.5-25W 2. Pulse frequency:33.3 Hz |
Scan Graphics | Square, rectangle, round or customized graphics |
Dot quantity | 400 dots at most |
Working state | Hyper-pulsed mode |
Scan mode | Sequence scan or Random scan |
Pulse energy | 5mj to 80mj is optional for each dot. OUR VALUE MESSAGE IS “QUALITY IS OUR CULTURE” |
Laser apparatus | Sealed off laser device stimulated by direct current |
Condenser focus | f=100mm |
Beam divergence angle | 0.3 mrad |
Spot size | Min 0.1mm at the focus |
Max power intensity | 75,000 W / cm² |
Radiation time | 0.01 1 sec |
Interval time | 0.01 1 sec |
Aiming beam | Less than 2mW, 635nm red semiconductor laser |
Beam transport device | Articulated arm with six segments and balance weight |
Power supply | 220±22V AC, 50±1Hz,10A |
Photos:
CO2 laser system
The CO2 laser with a specific wavelength of 10.6 nm can be absorbed by human body tissue (no matter what color the skin is) by nearly 100%. Through laser emitter, the micropulsed laser beam shoots on the target skin in nanometer level to achieve a controllable precise treatment .The dimension of shooting area only can be measured in nanometer, which is precise enough for operators to control and adjust the treated depth andlayer according to the clinical diagnosis.
The energy of CO2 laser is even and steady. Its focused energy aims only at target tissue without any injury to surroundings. It is the heat and electromagnetic effect of the laser that people use to conduct non-blood or less-blood cutting, cauterizing, gasification and accurate microsurgery so as to avoid skin burnt. During the treatment, biochemical reactions of optical-thermal accelerate collagen reproduction and skin recovery,after exfoliation of the tiny scar; fresh and smooth skin can be regenerated. The device outputs invisible laser. In order to operate with more ease, red semiconductor laser has been added to indicate.