Mongolian Spots Removal 2015 TOP Sale Best!!! Q Facial Veins Treatment Switch Nd Yag/ Tattoo Removal Laser Machine /CE
USD $999.99 - $1,699.99 /Piece
Min.Order:1 Piece
Guangzhou Magic Belle Beauty Device Co., Ltd.
The premium Q-switched Nd:YAG Laser offers the light of single wavelength 1064/532nm with sequential and uniform energy output, which will be on the target tissue directly to shatter pigments cell, not damage any normal tissue. It is very safe and effective treatment procedure for various tattoo and pigment lesions.
By bonding technology, the treatment performance is more effective than previous, it is our newest development with advantages of no light leakage, no need to debug, lower than 1‰ maintenance and much longer life time.
2015 TOP sale best!!! Q switch nd yag/ tattoo removal laser machine /CE
Product Description
The Q-switched ND YAG laser takes specific wavelengths light in high energy, which are absorbed by the pigment and shatters the pigment into particles, breaking them into very small fragments , some parts will
consequently bounce out of the skin and the other parts will spilt even further into minute particles; which eventually will be engulfed by the phagocytes and ultimately gets eliminated by the lymphatic system.
Application
1064nm wavelength tip:mainly cure the black,blue ,cyan, bluish violet old red tattoo and pigments;
532nm wavelength tip: mainly cure the red,green,brown colored tattoos and pigments;
BD-LS wavelength tip: whitening , shrinking pore , remove acne , remove blackhead.
Machine Advantages
1.Water flow and temp monitor ,it will automatically stop working when water temperature is in excess of the preset temperature or machine has little water flow.
2.Infrared ray aiming: imported infra-red indicator greatly increases the spot accuracy and the efficiency, saving cost accordingly .
3.Multilingual arbitrary languages selective .
4.New High power hand piece, strong output energy .
5.Integrated laser cavity, anti-vibration and anti-swing, no beam deflection.
6.Green Power Supply, Europe CE standard, integrated design, easy maintenance .
7.Adopt the world’s most advanced ABS insulation material, anti-interference capability and portable type easy for remove.
8.Q-switched without permanent replacement .
9.Remove pigmentation without side effects or scar .
10.Adopt imported lamp with original packaging, Greatly improve the whole life .
11.Adopt special diffuse reflection cavity, high reflection efficiency, high power endurance .
Accessories:
Technical Specifications
Laser type | Q-Switched Nd: YAG laser |
Wavelength | 1064nm 532nm BD-LS |
Energy | 1000MJ@1064nm 400MJ@532nm |
Laser simmer | Yes |
Pulse repetition rate | 1-6Hz |
Cooling | Semi-conductor water cooling system |
Power supply | AC110V/220V+10% 50/60Hz |
Size | 58×50×50cm |
Weight | 25kg |
Parameter adjustment of the laser treatment
Treatment Items | power | Frequency |
BD-LS(Black doll) | 550mj start with 550mj and increased up the burst strength | 4-5 |
1064nm | 550mj start with 550mj and increased up the burst strength | 4-5 |
532nm | 550mj start with 550mj and increased up the burst strength | 4-5 |
TREATMENT THEORY
Q-switched nd yag laser radiates the light ia absorbed by the pigmentations and results in an instantaneous blast that is light blasting principle The pigmentation particles are shattered into fragments some can be bounced out of the skin and others can be splited into tiny particles that can be engulfed by phagocytes and then eliminated by the lyphatic system.
Requirement before treatment:
1) Beautician should make record for customers, fully understanding customers’ skin condition and chose the right laser mirror,
at the same time communicate with your customer freely to let she or he feel relax.
2) Clear treating part skin and wait until it is totally dry and sterilize every apparatus.
Requirement before treatment:
1. Preparation before treatment by:
1) No inflammation in the treatment part.
2) No treatment for pregnant woman.
3) Fomentation on the treatment part avoid skin dehydration.
4) No cosmetic left ,clean the treatment part.
5)Taking photo before treatment, compare the effect after operation.
2. Skin appearance after treatment:
1) Reddish swelling on treatment part on the moment, it will disappear shortly.
2) To some special customers need to be higher, when you make the Volt too high, there comes the scab, but it will drop off naturally
after 7 days, not to scratch it, skin becomes normally about 2 days. Taking some Vitamins can lighten the pigment circumfluence.
Usually there is a feeling of scorching or slight bleeding, it is normal and no scar.
3) When the scabs fade away, the treatment part shows pink, 2-3 weeks later it appears coffee color, and 1-2 months later recover.
3. Care after treatment:
1) Can wash the skin with water or Non-stimulator after treatment.
2) If there is slight bleeding when adjust the Volt higher, please wipe off and smear the Antiphlogistin (such as Illotycin) until the scar
drops off. Not cosmetic or other medicines.
3) If the treatment parts is flush and feeling it not comfortable, can do ice compress.
4) Before the scab dropping off, the treatment part must be care not to touch water, not being scratching, avoiding certain food of hot,
dark color of coffee, Coco Cola etc. Prohibit smoking and drinking .Let the scabs desquamate naturally not scale off in a force.
5) Not taking plenty of sports avoiding of sweat infection.
6) After the scab desquamating, No need to coat the Illotycin (Erythromycin) again, just smear the suntan lotion (SPF15 upwards) even
in the room preventing UVA/UVB and keep along 3 to 6 months because of the treatment skin sensitivity to the sunlight. Using suntan lotion
or umbrella preventing can improve the effect early.
7) Period for laser treatment: According to the different treatment parts and pigment dark or not, the treatment may be several times. Normally
one period of treatment is 1-2 times, every time at 20-30 days interval. If there is no special, every 2-4 weeks go to clinic check again, if there
is anything abnormally, please cure it early.
8) Pigment fadeaway is a slow process, for the pigmentation skin, normally it is 1-3 months. In order to get more favorable effect, repeated
treatment should be 1-3 months interval.
Maintenance:
1. Notice to use purified water or de-ionized water, not the mineral water or tap water.
2. Be careful not to irradiate the machine avoiding the surface of machine injured.
Common Questions and Fixing:
No signal after power on. The reason is that the power plug doesn’t reach it, please directly connect the power plug.
No signal after power on because of the fuse blowing. Please replace the fuse with 5A/220V AC or 5A/110v AC.
No signal on the screen because that the Crash-stop switch being pressed. Please lift the Emergency-stop switch up.
Touch-off light is off state pressing the button on the screen when the machine is on pre-ignition. One reason is that the Xenon Lamp is damaged need
to replace a new one.
Another reason is that the life time for Xenon is full, change a new one. Water leaking out of machine, because of the impact during on shipment process.
May in the tube joint. Please call the service people to deal with it.
If you feel the energy is not big enough or the curing treatment is not well enough, the reason maybe the temperature is too higher or no water in the machine
and damaged the body machine. Please stop firstly, after half an hour starting the machine again.
Terms of service: Free consulting services The Company at any time the phone, emial or online to answer customers' use, maintenance, repair issues.
Product within one year of free warranty service Since the date of purchase (ie equipment delivery use date), in addition to human factors (operation,
maintenance, and modification of the device structure) do not follow the product instructions, equipment problems, and can enjoy the warranty service
warranty regulations. Warranty Regulations The instrument host warranty for one year, can enjoy free repair within one year.
Other after-sales service description:
1. Malicious damage to the machine no warranty.
2.Warranty cause a malfunction due to human factors, maintenance services of the company are charged parts costs and labor costs.
3.Equipment failure, faster repair your equipment, be sure the fault conditions described clearly.
4.The Company reserves the final interpretation of after-sales service.
Parking&shipping
FAQ
Q1: What about the delivery?
♥Magicbelle
Q2: What’s the delivery time?
♥Magicbelle
Q3: How about the package?
♥Magicbelle
polyfoam or pearl wool) are available.
Q4: Do you have any timely technology supports?
♥Magicbelle
Q5: What’s the payment method?
♥Magicbelle
If you need to know more about our products, please contact me
24 hours service hotline
Whatsapp:0086-135 8051 2002
SKYPE:magicbelle.stephen
Function:
Remove spot and nevus
The speed of flashes could be set 3Hz/5Hz.Keep 3-4 fingers distance between head of handle and treatment area. It is better to use high energy for treatment until treatment area seeps a little blood. It is advised to use 1064 nm head for normal spot and nevus treatment, but for deep color spot and nevus, it is better to use 532nm head for treatment. It should have a 15-30days interval to continue next treatment until remove all.
1.Getting rid of tatoos ,eyebrow,Ota's nevus .
2. Acne treatment
3.Skin rejuvenation
4.Pigmentation treatment
5.Vascular treatment.
6.Eliminate and smooth wrinkles treatment
7.Professional tatoo removal machine for sale
8.Body Tattoo & Eyebrow Tattoo & Eyeliner Removal
9.Various Pigmentation Lesions such as Freckles, Sun Spots,
10.Color Spots, Age Spots, Nevus, Birthmarks
11.Deep Facial Cleansing & Rejuvenation Assisted With Carbon Cream