hypertention cold laser therapy

hypertention cold laser therapy

USD $120 - $260 /Piece

Min.Order:1 Piece

Supply Ability:
10 Piece / Pieces per Month
Port:
Wuhan
Payment Terms:
T/T Credit Card

Quick Details View All >

Place of Origin:
Hubei, China
Brand Name:
HNC
Model Number:
HY30-D

Hubei YJT Technology Co., Ltd.

Business Type: Manufacturer,Trading Company
Wuhan Hubei China
Main Products: Semiconductor Laser Treatment Instrument ,High Potential Therapy Device ,Millimeter Wave Therapy Instrument

Product Details

Specifications

1.Herviscosity, hyperlipemia, hyperlipidemia, hypertension,
2.Diabetes, ischemic heart and cerebral vascular disease.

  

Wrist type semiconductor  Laser Treatment Instrument (Model: HY30-D)

 

Therapeutic Principle:

Our Semiconductor Laser Therapeutic Instrument has been developed base on modern laser medicine and clinical practice. It adopts low-level laser with the wavelength of 650nm, through specific parts of irradiation and using light radiation of laser and wavelength relation to change the biological characteristics and peel off the fat layer and cholesterol wrapped in the red blood cells, to improve the activity and oxygen carrying capacity as well as the deformability of cells, reduce the concentration of middle molecules in the blood, improve hem rheological properties and lower triglycerides and cholesterol, in order to effectively treat and prevent heat and brain diseases.

 

Traditional Chinese Medical Science

Radial artery: one of the surface superficial arteries. The reason to choose surface irradiation for the radial artery is the following:

l        Position of radial artery is much superficial compared with part of the body.

l        It is closer to the heart and the blood flow volume is larger with blood going through the radial artery per eight minutes (whole blood volume).

l        It's easy to touch and locate and runs along the vein.

So the laser energy can be easily absorbed by blood, so as to have a good effect.

hypertention cold laser therapy 

 

Neiguan acupoint: is at the two cross fingers inwards the first cross grain on the inner side of the wrist, shown as below. In the meridian doctrine of traditional Chinese medicine, the neiguan acupoint belongs to the pericardium meridian and is one of the eight confluence points. Large quantity of experiments and clinical practices have certified that the neiguan acupoint  has the following adjustment function to the heart:

 

l      It can adjust the abnormal heart rate in a bidirectional way. The high heart rate can be slowed down and the low heart rate can be accelerated;

l      It can increase the blood flow volume of the coronary artery in acute myocardial ischemia;

l      It can strengthen the myocardial contractility and improve the cardiac function. To have low level laser irradiation at the NEIGUAN acupoint is considered by experts as “one of the most outstanding and effective methods to treat cardiovascular and cerebrovascular diseases”. 

hypertention cold laser therapy

   

Nasal cavity is in a special position near to the brain. The brain is the nerve centre of the human body. There are abundant vessels and nerve systems. The blood circulation is going through here per three minutes. It is certified by the clinical experiments that laser irradiation at this position can not only relieve oxygen and blood lack in the brain, but also has an ideal effect on the rhinitis disease change.

hypertention cold laser therapy 

 

Function and Performance:

1)        Improving blood viscosity through laser blood irradiation.

2)        Improving blood oxygen carrying capacity through laser blood irradiation.

3)        Reducing blood-fat and total cholesterol through laser blood irradiation.

4)        Quickly and effectively correct the abnormity of lipid metabolism and maintain the equilibrium level of the lipid metabolism in the human body through laser blood irradiation.

5)        Improving the partial blood circulation around the nasal cavities and the immunological competence of the nasal mucosa membranes through irradiation the nasal mucosa.

6)        Therapeutic efficacy control on ischemic cardio-cerebrovascular diseases.

 

Application Range:

Hyperviscosity, hyperlipemia, hyperlipidemia, hypertension, diabetes, ischemic heart and cerebral vascular disease caused by ischemic cardiovascular and cerebrovascular diseases.

 

Features:

1)        Very effect in treatment, laser irradiate three parts or acupoints of human body at the same time, it has been sole proprietor in the market. 

2)        A laser stabilizer specially added to perform with more stability.

3)        Our semiconductor laser devices are used by high quality import laser head, which has the long life-span.

4)        Products owned five patents protection.

5)        Humanistic and scientific design to fit human physiological curve and ergonomics.

6)        Medical use of high capacity lithium battery for the energy-saving.

7)        Large LCD screen display the time, date and calendar, also work as a watch, it is multiple functions design.

8)        Using high-class and durable metal enclosure which is conducive to heat diffusion for the power stable.

9)        Time and power are adjustable, very smart memory system.

10)    Two output modes: Pulse and Continues, which have manual and automatic switch available.

11)    Pluggable laser wire, more convenience in use and easier maintenance.

 

Caution:

1)        Not suitable for the following groups: cancer patient, pregnancy, patient with hemorrhagic diseases.  

2)         

3)        Children shall only use the instrument under the direction of their parents.

4)        The elder patients and sensitive patients must accept the low-power and short-time treatment at the beginning, the rate of work could be increased as the body adjusts.

 

Technical parameter:

1.) Laser medium : GaAlAs Semiconductor 

2.) Laser wavelength: 650nm

3.) Terminate laser medium quantity : 6pcs.

4.) single laser medium terminate output voltage :≤5mw

5.) Terminate output laser control :3 grade for adjustment. 

6.) Fixed time range: 10 minutes to 60minutes, and six grade for adjustment.

7.) Battery voltage: 3.7 to 4.2V

8.) Lithium ion battery output voltage:5.5V

9.) Instrument power consumption:1 W

10.) Environment temperature:5°C-40°C

11.)Relative humidity: ≤80%

12.) atmospheric pressure:86kpa-106kpa

Contact Supplier

Ms. Judy Zeng Manager Chat Now
Telephone
86-27-51231823
Mobile
18271841197
Fax
86-27-86648605
Address
Block 7, Guannan Fuxing Pharmaceutical Park, No. 62 Optical Valley Road, East Lake Hi-tech Development Zone, Wuhan, Hubei Province, China Wuhan,Hubei

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Medical Devices > Physical Therapy Equipments
Categories
Hi~