Latest Beauty Salon Equipment Face Whitening Co2 Fractional Medical Laser Eye Wrinkle / Bag Removal
Negotiable /Set
Min.Order:1 Set
Beijing Shijizhengfang Science and Technology Development Co., Ltd.
Application:
1. Application Range of Fractional treatment handpiece
a. Large pores, Fine lines, Skin tightening and whitening, Skin loosen(Deep Wrinkles), Stretch marks.
b. Various Scars: Burn Scars, Acne Scars, Surgical Scars and Keloid;
c. Reconstruction of photoaging skin.
2. Application Range of Incision Handpiece
a. Via multiple handles it can be adapted to Gynecology, ENT, Neurology and general surgery
b. In cosmetic surgery, it can be adapted to incisions for Blephaplasty, Skin Tags and Ingrow Nails, Compound Nevus and Intra Dermal Nevus etc
Anybeauty medical laser rf fractional co2
Treatment Principle
Fractional Laser System fires a laser beam which is then split inti numbers f microscopic beams, producing tiny dot,or pixel-like treatment zones within the selected area of the skin,leaving the other zones within it perfectly intact. Therefore ,the heat of laser only passes deeply through the fractional damaged area. This allows the skin to heal much faster than if the whole area was treated. During the skin self-resurfacing , a great number of collagen is produced for skin rejuvenation. Eventually the skin will look much healthier and younger
Parameters
Application | 1. Remove acne, acne scar, scar and so on; | |||
Special Features | 1. US-imported RF-CO2 laser generator, high quality excellent performance; | |||
Technical Parameter | Electrical Requirements | AC 110V± 10% 60Hz | Beam Delivery | 6 joint arm |
Wavelength | 10600nm | Cooling | Air cooling | |
Aiming wavelength | 635nm | Output mode | Continuous, super pulse, fractional | |
Focal Spot Diameter | 0.25mm | Operating mode | Continuous, operation with, intermittent loading | |
Power of Aiming Beam | ≤ 5mw | Whether Preview or not | Yes | |
Pulse Interval | 1ms-5000ms, every stepping 1ms | Times of scanning | 1th-20 th, every stepping 1th | |
Pulse Width | 0.1ms-10ms, every stepping 0.1ms | |||
Scanning Mode | Disorder emitting, to one side as the base emitting in order, emitting by maximum distance | |||
Output Power | 30W (RF metal tube) | |||
Output Pattern | Beeline, triangle, right square, rectangle, hexagon, rotundity, ellipse and so on | |||
Spots Interval | 0.1mm-2.6mm, every stepping 0.1mm | |||
Pattern Size | Diagonal length from 0.1mm to 20mm is adjustable at random |
Technology of Ultrapulse
Mainly let the original average output of the laser energy concentrated in a very short period of time then output, due to the high pulse power, short time, and more round spot, the pressure on the surface from laser heat transfer effects is low (small heat-affected zone).
Medical CE and ISO 13485 Certificates
Before and After treatment
Two working modes: Fractional and Normal
Fractional mode for the removal of scar, acne , acne scar, wrinkles,stretch mark..
Normal mode for surgical cuttings
Plenty training(DVD+Manual+Online training)
Working area
Safe packing
Theory - co2 fractional laser