Professional Beauty Salon Equipment CO2 1ms-5000ms Fractional Laser Skin Activator
Negotiable /Set
Min.Order:1 Set
Beijing Shijizhengfang Science and Technology Development Co., Ltd.
Technology of Ultrapulse
Mainly let the original average output of the laser energy concentrated in a very short period of time then output, due to the high pulse power, short time, and more round spot, the pressure on the surface from laser heat transfer effects is low (small heat-affected zone).
Beauty salon equipment CO2 Fractional Laser skin activator
Application | 1. Remove acne, acne scar, scar and so on; | |||
Special Features | 1. US-imported RF-CO2 laser generator, high quality excellent performance; | |||
Technical Parameter | Electrical Requirements | AC 110V± 10% 60Hz | Beam Delivery | 6 joint arm |
Wavelength | 10600nm | Cooling | Air cooling Application:
1. Application Range of Fractional treatment handpiece 2. Application Range of Incision Handpiece | |
Aiming wavelength | 635nm | Output mode | Continuous, super pulse, fractional | |
Focal Spot Diameter | 0.25mm | Operating mode | Continuous, operation with, intermittent loading | |
Power of Aiming Beam | ≤ 5mw | Whether Preview or not | Yes | |
Pulse Interval | 1ms-5000ms, every stepping 1ms | Times of scanning | 1th-20 th, every stepping 1th | |
Pulse Width | 0.1ms-10ms, every stepping 0.1ms | |||
Scanning Mode | Disorder emitting, to one side as the base emitting in order, emitting by maximum distance | |||
Output Power | 1%-100%(adjustable), every stepping1%, 20W | |||
Output Pattern | Beeline, triangle, right square, rectangle, hexagon, rotundity, ellipse and so on | |||
Spots Interval | 0.1mm-2.6mm, every stepping 0.1mm | |||
Pattern Size | Diagonal length from 0.1mm to 20mm is adjustable at random |
Theory - co2 fractional laser
Treatment Interface
Medical CE and ISO 13485 approval
Treatment results comparision
Aluminum alloy case
DVD and online training
Working area
CO2 laser system
The CO2 laser with a specific wavelength of 10.6 nm can be absorbed by human body tissue (no matter what color the skin is) by nearly 100%. Through laser emitter, the micropulsed laser beam shoots on the target skin in nanometer level to achieve a controllable precise treatment .The dimension of shooting area only can be measured in nanometer, which is precise enough for operators to control and adjust the treated depth andlayer according to the clinical diagnosis.
The energy of CO2 laser is even and steady. Its focused energy aims only at target tissue without any injury to surroundings. It is the heat and electromagnetic effect of the laser that people use to conduct non-blood or less-blood cutting, cauterizing, gasification and accurate microsurgery so as to avoid skin burnt. During the treatment, biochemical reactions of optical-thermal accelerate collagen reproduction and skin recovery,after exfoliation of the tiny scar; fresh and smooth skin can be regenerated. The device outputs invisible laser. In order to operate with more ease, red semiconductor laser has been added to indicate.