Haemangioma Treatment Professional Nubway Long Pulse Nd Yag Laser Nd Yag Laser Machine Low Prices Laser Tattoo Removal Machine With CE Laser Tattoo Removal Equipment
USD $1,000 - $15,000 /Set
Min.Order:1 Set
Advantages:
1.Bipolar Nd:YAG laser: Available with 800mj by single pulse energy .it’s the unique high-tech laser with Max energy of 1600mJ.
2.The erminator of Tattoos: No pain,no burn and even no aneasthesia!
3. Laser lamp:imported from America with more than 500,000 pulses!
4.German designers conducted industrial and inner structure designing ,while with ABS aviation material, so as to achieve anti-interference, Antistatic corrosion resistance ,and flame-resisting.
Professional Nubway long pulse nd yag laser nd yag laser machine low prices laser tattoo removal machine with CE
Laser Skin-care System
Pigmented lesion: Yiteng lentigines, Taitian Lentiines, freckles, eyebrow tattoo, body tattoo, lips tattoo.Vascular lesion: Pigment with red, brown, blue and black; vascular expanding
Pretreatment preparation
Make sure whether the clients’ skin is keloid skin, and learn whether they have purified their eyebrows, pigment with other means.
Explain to clientele that after riding of pigment still having pigment trace left which previously caused by sunburn.
Let clientele know that even after riding of the black and blue pigments still having brown and red left for the presence of composite painting material.
Better shave the client’s eyebrow for easy operating before the treatment.
Technical parameter
Dimensions | 920× 555 ×1065mm not including joints arm |
Weight | 100kg |
Wastage power | 800VA |
Fuse | 220V, 10A |
Output mode | Q-switch Pulsed output |
Wavelength | 1064nm, 532nm |
Pulse Duration | 10±3ns |
Frequency | 1Hz, 2Hz,5Hz |
Single Pulse energy | 250mJ-1500mj |
Safety distance | NOHD 1km. Operator must wear goggles |
Cooling system | Water cooled |
Work mode | Continually work with intervals |
Spot Size | Continually adjustable |
Feature:
1. The latest hi-tech of laser explosion in twinkling.
2. Don’t break the hair follicle, or hurt the normal skin, or produce the scar formation.
3. Little sense of pain, anesthesia is unnecessary.
4. Short curing time and easy operation.
5. The high quality controlled solid-state laser complying with international standard of production.
6. Computerized with big LCD and show in double languages,English and Chinese.
Product Show
Tratement principle:
Therapy of epidermis and dermis pigmentation-----Utilizing the explosive effect of the Nd: YAG laser, the laser permeate the epidermis into the dermis which includes amount of pigment mass. Since the laser pulses in nanosecond but with super high energy, the shot pigment mass swell quickly and breaks into small pieces, which will be eliminated through metabolic system.
Therapy of the dilatation of capillary vessel---- Utilizing the heat effect of the Nd: Yag Laser, the laser is absorbed by the hemachrome in the capillary vessel, then the capillary vessel become blocked and disappear.
Specifications and performance Guideline
Environmental conditions
1. Temperature: 10℃~30℃
2. Relative humidity: ≤75%,Air pressure: 860-1060hpa,Power requirement: AC 220v±10%;50Hz±2%, Water: Distilled water
Tratement result
Advantage
Components of the Unit Description
LCD screen :Show the work status and adjustable specifications.
Handrail :Protect the main body and move the machine in short distance.
Key switch :Turn on or turn off the system.
Emergency shut-off Knob:Turn off the system on emergency.
Joints arm:Transfer the light to the target area.
Transformer
Applications:
1. Remove coffee, brown and all kinds of tattoo;
2. Dermis spot, fleck, black nevus, age pigment, birthmark and Nevus of Ota;
3. Remove all kinds of embroider eyebrow, embroider lip, soak lip, embroider eye line and lip line.
Power supply socket :Connect with the power supply line plug.
Pedal switch socket :Connect with the pedal switch.
Foot Pedal: Control the output of laser emittance.
Environment requirement of installation and operation
The room should be clean and no dirty
Air conditioner, Voltage transformer and dust collector is necessary.
Transportation of the Device
The power supply, laser generator and joints arm should be paced separately with original shock proof package supplied by the manufacturer.
Installation is only allowed on place by professional technician.
Installation of the system
Installation is only allowed on place by professional technician.
After installation finished, The technician must adjust and calibrate the display error, the exactness of the cursor, the diameter of the spot size, the single pulse energy and power supply
1. 3 years warranty for the mainframe without charges for components change or repairing. Lifetime maintenance without any charge.
2. Free training for operation of the equipment in our company, which provided by our specialized training department.
3. On-line services, for example, technical consultancies provided by our skilled technique group concerning any question of the laser equipment, and after-sale maintenance and more.
4. OEM/ODM services are available. We have our own developing and design department and manufacturing line, which ensure your required beauty equipment.
Company Info
Beijing Nubway S & T Development Co., Ltd is the professional manufacturer of beauty equipment,
medical equipment, Skin Analyzer System Beauty Salon products and so on.
Our company was built in 2003, we have our own research and development department and our
own factory so we can provide OEM and ODM service for the distributors all over the world.
Contact
Sharon
Beijing Nubway S & T Co., Ltd.
address: Room 805 No.12 Yabao Road, Chaoyang District, Bejing 100020, China
Tel: +0086 10 51206522
website:
Skype/Email: Sharon(@)
Working Principle:
Laser emitted by the system has a strong penetration ability which allows it to reach
the deep layer of dermis. The pigment particles absorb the light energy and explode
sharply, burst into the tiny pieces, thus diminish the color density and get rid of it.
So the appliance can effectively do away with mutant pigmentations and vascular tissue
based on undamaged ambient tissue. This is called ‘Selective heat absorption’ principle
in medical field.