New medical equipment ecg machine with stethoscope
USD $250 - $250 /Piece
Min.Order:1 Piece
Guangzhou Joyful Technology Co., Ltd.
JOYFUL medical equipment ecg machine with real-time detecting fuction
2016 promotion product medical equipment handheld single channel ECG machine
ECG machine price for auscultation, ECG acquisition, SpO2 and pulse rate monitoring
Pathological Analysis Equipments Type hospital ecg machine pm-8000 pirce
The system can transform biomedical signal into electric signal through signal detection and reprocess Module, at the same time preprocess interference suppression, signal filtering and amplification and so on. Then it will conduct a computational analysis to the parameters after the sampling and quantification through data extraction and Preprocess Module.
The results will be monitor and compared to threshold
value, which may lead to an Alarm. The result date will
be stored to RAM in real time, which can be transmitted to a PC. The PC can show all the
parameter values in real time.
1)Compact and portable, easy to use
2)Display of ECG waveform, heart rate, SpO2, pulse rate, pulse waveform
3)Earphone output and 16 steps volume adjustable
4)Alarm for SpO2 and pulse rate exceeding limits
5)Real-time detecting, TF card data record and review
6)Real-time clock
7)Recorded data can be transferred
to a PC
8)PC analysis software
9)Low power consumption
(1) Measurement of auscultation volume
(2) Measurement of Heart Rate
(3) Measurement of SpO2
(4) Measurement of pulse rate
(5) Measurement Performance in Weak filling
Condition
(6) Resistance to surrounding light
Lung sound range: 100Hz~800Hz
Heart lung combination sound range: 20Hz~800Hz
Range: 30bpm~300bpm
Resolution: 1bpm
Accuracy: ±2bpm or ±2%(select larger)
range: 0%~100%
resolution: 1%
accuracy: When the SpO2 measurement range is 70%~100%, the permission of absolute error is ±2%. Below 70% unspecified.
Range: 30bpm~250bpm
Resolution: 1bpm
Accuracy: ±2bpm or ±2%(select larger)
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2%(select larger).
The deviation between the value measured in the condition of man-made light and indoor natural light and that of darkroom is less than ±1%.
Guangzhou Joyful technology Co., Ltd. is manufactory special at making health care and beauty
equipment in Guangzhou, China for more than 10 years. Our main product including cool technic
body slimming machine, laser hair removal
machine, Hyperthermia Machine, ECG machine,
pulse oximeter and etc. We are insist to provide
high quality product with competitive price to
meet customer needs.
Everything runs under strict quality control systems to ensure the high quality and competitive prices of our products. Our products consistently meet CE and other international standards.