500W Cavitation+cryolipolysis Slimming Machine Beauty Equipment 8.4" Screen
Negotiable /Set
Min.Order:1 Set
Guangzhou GLM Beauty Spa Equipment Factory
Cavitation+cryolipolysis slimming machine beauty equipment
1. Technology background
Too much fat damage people’s appearance and athletic ability may also cause various diseases. Too much fatty tissue can be located in various parts of the body, including the thigh, buttocks, abdomen, knee, back, face, arms and other areas. And an excess of adipose tissue may be cause ugly appearance formed by cellular. Excess body fat also related to significant health risk. So we need effective method to control or eliminate excess body fat.
_________________________________________________________________________________
Liposuction is a cosmetic surgery procedure that slims and reshapes specific areas of the body by removing extra fat deposits. Usually operated by the Plastic Surgery or dermatologist with special surgical instruments for liposuction, it is an invasive way to remove subcutaneous fat tissue.
_________________________________________________________________________________
There are also possible fatal complications and negative side effects associated with having liposuction. These temporary factors include swelling, painful bruising, pain, numbness, limited mobility and allergic reaction. In addition, liposuction is of high cost. There are other new emerging technologies to remove subcutaneous adipose tissue, including Mesotherapy laser-assisted liposuction and high-intensity focused ultrasound.
__________________________________________________________________________________
Other non-invasive way to remove excessive fat including drugs, diet pills, regular exercise, diet control, or a combination of these methods. A disadvantage of these treatments is likely invalid, and even in some cases impossible. For example, when a person physically injured or sick, you can not select the way of regular exercise. Similarly, when the diet pills or external use of drugs are allergic or cause adverse reactions, in addition, the use of physical or systemic approach to lose weight, you can not eliminate the body fat of a selected area.
__________________________________________________________________________________
The Cooling procedure using Cryolipolysis is fundamentally different from other non-or minimally-invasive modalities, and it was approved as the most effective way to fat reduction.
__________________________________________________________________________________
This revolutionary fat loss method is approved as an important technology progress in fat reduction since it has put into use. For those people who are on diet, do regular exercise but still remove local fat, Cryolipolysis definitely a great gift. For fat intensive parts and less parts, such as love handles (flanks), and back fat. (Loose fat above the hip on both sides of waist), belly and back fat, Cryolipolysis can produce stunning results.
_________________________________________________________________________________
2. Cool Technology
As triglyceride in fat will be converted into solid in particular low temperatures.
It uses advanced cooling technology to selectively target fat bulges and eliminate fat cells through a gradual process that does not harm the surrounding tissues, reduce unwanted fat, when fat cells are exposed to precise cooling, they trigger a process of natural removal that gradually reduces the thickness of the fat layer. And The fat cells in the treated area are gently eliminated through the body's normal metabolism process, to eliminate unwanted fat.
_________________________________________________________________________________________________
3. Operations:
Smear gel or slimming products (normally 20-30g per time) onto the fat parts. Use the Cryoprobe head to freeze the fat in fixed position. Set the operation time to be 20-30 minutes (set the freezing temperature to be around 5°C).
Smear gel or slimming products (normally 20-30g per time) onto the fat parts. Use 40K fat-dissolving head to blast the fat in fixed position or apply it to the fat parts in a circular motion to blast fat. Set the operation time to be 20-30 minutes (the explosion intensity is recommended to be set to be the second level).
Smear gel or slimming products (normally 20-30g per time) onto the fat parts. Apply multipolar RF fat-burning head to the fat parts in a circular motion to blast fat. Set the operation time to be 20-30 minutes (the radio frequency intensity is recommended to be set to be the eighth level).
OUR VALUE MESSAGE IS “QUALITY IS OUR CULTURE”
“WITH US YOUR MONEY IN SAFE YOUR BUSINESS IN SAFE”
1. 100% after-sales quality assurance, Support Many payment method;
2. All other specifications of beauty equipment are available according to your requirement(OEM&ODM)! Factory price you will get from NUBWAY
3. We can provide professional operation training.
4.Nd yag laser, cryolipolysis machine, hair laser machine etc with CE ISO FDA certifications and strong supply ability.
4.Accessories:
1. Cryoprobe head
2. 40K strong sound wave head
Technical Features:
* The latest technology in non-surgery mechanical beauty industry
* The most popular slimming way in European countries
* Suitable for slimming for body parts like back,waist and cellulite
* First treatment can eliminate 26% fat
* The newest generation fat cryolipolysis machine, the most specialty! the most intelligentize!! The most stabilization!!!
3. Multipolar RF body head
5. Notes:
In case of first use of cryoprobe, the machine water tank must be filled with coolant. ( see on the picture above, when the coolant outflow from overflow outlet. It means the machine is already filled of coolant.)
_________________________________________________________________________________________________
Add coolant to the machine on a regular basis (often supplement once a week).
__________________________________________________________________________________________________
First operation, The water pump inside is first stared, coolant may not be able to reach the handle. Pls try to anti-press star and stop button until the coolant can reach handle to play a circulating cooling effect.( start and stop button interval of about 30 seconds). 3. When use of cryoprobe, the left and right sides of the suction cup are severe fever and sustained high temperatures at about 50degree, indicating that the cooling system is not working properly and the coolant can not be transported to the handle.
_________________________________________________________________________________________________
The coolant in the water tank must be discharged during packaging and transporting of the equipment.