GLM TOP DESIGN best selling F-030 Desktop 2 HIFU Heads with cooling system for sale
USD $1,000 - $1,600 /Set
Min.Order:1 Set
Guangzhou GLM Beauty Spa Equipment Factory
Desktop HIFU/2 HIFU Heads for face and body with cooling system
HIFU Principle
High intensity focused ultrasound technology is an ultrasonic surgical technology rising in 40's of last century, the ultrasonic energy source, using its penetrating and focusing ultrasonic issued to human SMAS layer, forming a sound intensity higher region -- the focal region within SMAS, but thorough subcutaneous 3.0mm-4.5mm make the SMAS organization in the 0.5 -second temperature up to 65 ℃ (all non intrusive firming the strongest temperature instrument) resulting in the SMAS organization of collagen recombination without damage to normal tissue outside the focal region, so as to enhance the effect of fascia.
What is SMAS?
Lift operation at present by plastic surgeons do operation layer, the SMAS layer, which is(superficial musculoaponeurotic system, referred to as the fascia (fascia) SMAS) layer on the skin depth is about 4.5mm, subcutaneous fat and musc
Function of HIFU
Double-Handle HIFU is the cosmetological instrument for resisting wrinkles, fighting ageing and nourishing skin for the body, it adopts HIFU high energy focused ultrasonic technology to focus the intensive ultrasonic on the skin of the desired part, and can take effect in the SMAS aponeurosis layer without hurting the epidermal tissue of skin, combining the RF matrix radio frequency, it promotes the thermal reaction for skin tissue and change in the fine “Focused Area” with thermal energy.
Technical Parameters of hifu
1. HIFU for Body
HIFU Power | 7J/CM2 |
Function Area | 6CM2 |
HIFU Frequency | 4.5MHZ |
Effect of Depth | 4.5MM |
RF Power | 6J/CM2 |
Function Area | 4.5CM2 |
Effect of Depth | 3MM |
Frequency | 3MHZ |
LED wavelength | 650NM |
Strength | 5000mcd |
Energy Output Mode | Keying/Touching |
2. HIFU for Face
HIFU Power | 5J/CM2 |
Function Area | 4CM2 |
HIFU Frequency | 3MHZ |
Effect of Depth | 4.5MM |
RF Power | 4J/CM2 |
Function Area | 3CM2 |
Effect of Depth | 3MM |
Frequency | 2MHZ |
LED wavelength | 650NM |
Strength | 5000mcd |
Energy Output Mode | Keying/Touching |
3. Cooling Head
Cooling temperature | 3-6 ℃ |
HIFU Skin tighten process
1. Skin cleaning
2. Take photo and mart the treat skin area
3. Put gel as a conductor between the transmitter and the skin
4. Mark the treating area,such as around the chin,neck,both sides of the plane
5.Pay attention to avoid the edge of the chin nerve(marginal mandibular nerve) and supraorbital never(supra orbital never) area
6. After completion,and no recovery period,can use skincare products and make-up
7. Just once,the full effect will gradually aprear in 2-3 months time
Packing: Carton, Wooden, Aluminium Case