Principle:
Fractional resurfacing is a new laser treatment modality that creates numerous microscopic thermal injury zones of controlled width, depth,and density that are surrounded by a reservoir of spared epidermal and dermal tissue,allowing for rapid repair of laser-induced thermal injury. This unique modality, if implemented with proper laser- delivery systems, enables high-energy treatments while minimizing risks.
2.This machine use the RF Tube manufacturerd by Coherent America,the frequency can reach more than5000HZ,the high speed can work more efficiecnt and effectively,it is very good for the ultra pulse incision for the precise surgey,no blood,the treatment area is very clear,andless down time.
Specifications
1.scar removal,acne removal
2.Life long technical surpport
3.one year warranty
4,Medical CE
CO2 fractional laser scar removal machine for skin care OB-FC 01
Welcome to concern our product,Ostar Beauty Sci-Tech Co Ltd is your the best choice becauce of its unique pattern, superior quality, and reasonable price,I will reply to you within one day.
co2 fractional laser
1.scar removal,acne removal
2.Life long technical surpport
3.one year warranty
4,Medical CE
Fractional Co2 laser treatment:
Features:
1. Reduced thermal damage to surrounding tissues
2. Rapid healing and minimal downtime
3. Stimulate deeper collagen with high pulse energy
4. LCD display panel provides easy operation with the latest microprocessor technology
5. Adjustable scanning patterns and size
6. Adjustable intensity of pilot beam from zero to maximum
7. Adjustable pulse duration
8. Last treatment setting memorization
9. Automatic alarm system for operation and troubles
10. Covers all functions of conventional system
11. No consumable costs
Ultrapulse fractional co2 laser emits thousands of deep, tiny focal spot columns in your skin, called microscopic treatment zones. These lights penetrate into dermis skin, gasify the tissues around wrinkles and scars in an instant and make a signal of compounding collagen like tissues repair, collagen rearrangement ettc to regain a new fresh and healthy skin of youth.
Specifications:
Output Power: 1~30W adjustable
Micro Pulse Energy: 5mj-100mj, 16 steps adjustable
Estimated Power : 125mj-1kj
Scanner Focus : F=50mm(generation 2) or f=100mm(generation 1)
Focus Spot Diameter: ≤0.1mm(generation 2), ≤0.2mm(generation 1)
Treatment Depth: 2000μm(generation 2), 600μm(generation 1)
Indication beam: green semiconductor laser (532nm, 5mW)
System control: microcomputer control
Smoke Exhausting System: Built-in air blow
Cooling System: Built-in circulating water cooling
Display Screen: Color LCD (8 inch Touch Screen)
Transmission System: 7-Articulation Joint Spring-Balanced Light Guiding Arm
Working Model: With scanner (galvanometer scanning)
Scanning area: 0.1×0.1mm-15×15mm
(generation 2)
0.1×0.1mm-20×20mm
(generation 1) scanning
graphic: Rectangular, Ellipse (standard)
Scanning velocity: 0.1 to 9 cm2/s adjustable
CW: output power, 1-30w, 1w adjustable
Pulse: interval time, 0-999ms, 1ms adjustable
Ultra: Frequency, 1000hz, 1hz adjustable
Treatment control: footswitch
Environmental temperature: 5-40oC
Relative Humidity: ≤80%
Machine Weight: 40kg
Machine Dimension: 45cm× 55cm ×140cm
Power Supply: AC 220V±22V; 50hz, 3Amp
I Theory:
The carbon dioxide laser (CO2 laser) was one of the earliest gas lasers to be developed (invented by Kumar Patel of Bell Labs in 1964, and is still one of the most useful. Carbon dioxide lasers are the highest-power continuous wave lasers that are currently available. They are also quite efficient: the ratio of output power to pump power can be as large as 20%.
The CO2 laser produces a beam of infrared light with the principal wavelength bands centering around 9.4 and 10.6 micrometers. With fractional laser resurfacing the laser beam is broken up or fractionated into many small micro beams which are separated so that when they strike the skin surface small areas of the skin between the beams are not hit by the laser and left intact. These small areas of untreated skin promote a much more rapid recovery and healing with less risk of complications. The small areas treated by the fractional micro beams, called micro treatment zones, cause sufficient laser injury to promote new collagen production and resultant facial skin rejuvenation.
II Application:
1. Acne and acne scar removal
2. CO2 fractional laser skin tightening
3. Skin renewing, wrinkle removal
4. Smooth burnt scars and surgery scars, dermabrasion etc
5. Remove intractable chloasmas and pigmentation
III Advantage:
1. Truly portable, continent
2. New-developed hand piece
3. Infrared ray aiming
4. Water-flow monitor
5. Water flow and temp monitor
6. Plug and play function
Brief Introduction
Refine super pulsed CO2 laser Refine is a classic minimally invasive laser equipment for dermatologic surgery. This latest super pulsed laser emission system delivers hundreds of orderly micron pulsed laser beam on skin lesions, for controllable and accurate treatment by means of adjusting the size, density, distance,nature of the multiple arrays, and the diameter and the depth of the pore.
The treatment of Refine is very safe and can cover any part of the body. Its applications include a variety of wrinkles(forehead lines,eyebrow lines,eye wrinkles,perioral wrinkles,neck lines,stretch marks etc.),sagging skin, drooping eyelids, eyes bags, acne(whelk) marks, all kinds of scar(trauma scar,burn scar,suture scar),stains etc.