590-1200nm Sun Damage Recovery Rf Tube Co2 Fractional 1ms-5000ms Laser Used Beauty Salon Equipment OstarBeauty FC 01 2.6MHZ
USD $800 - $12,000 /Set
Min.Order:1 Set
OstarBeauty trialma laser hair removal 808 laser diode CE Approval DH 04
808 laser diode CE Approval Laser Beauty Equipment OstarBeauty DH 03N
Aluminum Alloy packing depilation machine laser beauty equipment CE Approval 808nm laser DH 02
Laser manufacture tattoo removal machine beauty salon used laser pigment removal TR 03
Portable Q Switch ND Yag laser tattoo removal machine CE Approval and pigment removal TR 02
Q Switch ND Yag laser for tattoo removal 1800MJ include skin rejuvenation function TR 01
Fuctions and treatment effect of elight ipl rf
1.Permanent hair removal.
2.Smooth wrinkles, face-lifting
3.Deep flecks, epidermis flecks or pigment treating the telangiectasis
4.Promote collagen to grow, strengthen flexibility of skin
5.Acne treatment
6.Shrink the thick pore
7.For endogenous pigment: nevus of Ota, coffee spot, age pigment, freckle etc removal
8.For exogenous pigment: tattoo, eyeliner and eyebrow removal
9.Skin whitening
10.Striae gravidarum removal
Application:
1. Application Range of Fractional treatment handpiece
a. Large pores, Fine lines, Skin tightening and whitening, Skin loosen(Deep Wrinkles), Stretch marks.
b. Various Scars: Burn Scars, Acne Scars, Surgical Scars and Keloid;
c. Reconstruction of photoaging skin.
2. Application Range of Incision Handpiece
a. Via multiple handles it can be adapted to Gynecology, ENT, Neurology and general surgery
b. In cosmetic surgery, it can be adapted to incisions for Blephaplasty, Skin Tags and Ingrow Nails, Compound Nevus and Intra Dermal Nevus etc
rf tube co2 fractional laser
Dear friend,This is Zulie from Ostar Beauty Sci-Tech Co Ltd, pls feel free to contact us! we will reply you at once!
OB-FC 01
Specifications:
1) Wavelength | 10.6μm |
2) Output Power | 1~30W adjustable |
3)Micro Pulse Energy | 5mj-100mj, 16 steps adjustable |
4)Estimated Power | 125mj-1kj |
5)Scanner Focus | F=50mm(generation 2) or f=100mm(generation 1) |
6)Focus Spot Diameter | ≤ |
7)Indication beam | 2000μm(generation 2) 600μm(generation 1) |
8)No.charging cycles | green semiconductor laser (532nm, 5mW) |
9)System control | microcomputer control |
10)Smoke Exhausting System | Built-in air blow |
11)Cooling System | Built-in circulating water cooling |
12)Display Screen | Color LCD (8 inch Touch Screen) |
13)Transmission System | 7-Articulation Joint Spring-Balanced Light Guiding Arm |
14)Working Model | With scanner (galvanometer scanning) |
15)Scanning area | 0.1×0.1mm-15×15mm(generation 2) 0.1×0.1mm-20×20mm(generation 1) scanning |
16)Graphic | Rectangular, Ellipse (standard) |
17)Scanning velocity | 0.1 to 9 cm2/s adjustable |
18)CW: output power | 1-30w adjustable |
19)Pulse | 0-999ms, 1ms adjustable |
20)Ultra: Frequency | 1hz- 000hz, Principle of RF CO2 Fractional Laser CO2 Fractional Laser System fires a laser beam which is split into numbers of microscopic beams, producing tiny dot or fractional treatment zones within the selected target area only. Therefore, the heat of laser only passes deeply through the fractional damaged area. This allows the skin to heal much faster than if the whole area was treated. During the skin self-resurfacing, a great amount of collagen is produced for skin rejuvenation, eventually the skin will look much healthier and younger. |
20)Treatment control | footswitch |
21)Environmental temperature CO2 laser system The CO2 laser with a specific wavelength of 10.6 nm can be absorbed by human body tissue (no matter what color the skin is) by nearly 100%. Through laser emitter, the micropulsed laser beam shoots on the target skin in nanometer level to achieve a controllable precise treatment .The dimension of shooting area only can be measured in nanometer, which is precise enough for operators to control and adjust the treated depth andlayer according to the clinical diagnosis. The energy of CO2 laser is even and steady. Its focused energy aims only at target tissue without any injury to surroundings. It is the heat and electromagnetic effect of the laser that people use to conduct non-blood or less-blood cutting, cauterizing, gasification and accurate microsurgery so as to avoid skin burnt. During the treatment, biochemical reactions of optical-thermal accelerate collagen reproduction and skin recovery,after exfoliation of the tiny scar; fresh and smooth skin can be regenerated. The device outputs invisible laser. In order to operate with more ease, red semiconductor laser has been added to indicate. | 5-40oC |
22)Relative Humidity | ≤ |
23)G.W Treatment theory e-light beauty equipment CE beauty machine combines three advanced technologies:Bipolar Radio Frequency + IPL + Skin Contact Cooling The working theory is heating the dermis to a target temperature gradually,at that target temperature, it damages the hair follicles and prevents re-growth effectively,meanwhile avoiding injury to the surrunding tissue.A high repetition rate of single pulses are delivered deep into the dermis,achieving high average power and therappeutically effectively heat bulit-up,without the risk of injury and no pain virtually. | 65kg |
24)Machine Dimensio | 45cm× 50cm ×130cm |
25)Power Supply | AC 220V±22V; 50hz, 3Amp |
Packing:
Shipping: Express, door to door service / Air Shipping / Seas Shipping
Sample Service:We would like to offer you a sample with a low costs.
OEM Service: Laser printed logo on the device
Warranty Service: Two Years warranty
Life long technical support
Various training
Certification
Exhibition Show
Business Show
Welcome to my page, We are very pleased to work with you if we can
Main Technical Parameters:
Laser wavelength: 10.6µm
Laser unit:TEM00 module Co2 unit (best quality for the facula)
Output power: super pulse output 0.3-7W, peak value 450W,continuous output 0.3-25W
Laser output mode: continuous, single pulse, repeat pulse, super pulse, with the optional pixel laser handpiece for Pixel laser output mode
Conducting system: seven joints longer articulated arm(the most advanced conducting light system in the world and the only one in China). It could be operated in the scope of R=1.7m, which makes the operation more flexible
Handpiece:multiple function handpiece and two kinds of focus lens for f=100mm and f=50mm. With the optional adapter, it could be used for orthopedic, gynaecology and ENT surgery
Operation mode:controlled by a touch screen and with the engineer interface and the doctor interface
Min. spot diameter:≤0.1mm, variable spot adjusting handpiece:0.1-2.5mm
Pulse width: the minimum pulse width is 0.1ms
The range of IPL treatment:
(1)Everlasting hair removal:remove unwanted hairs under arms,on legs ,lips or other body part,etc.
(2)Pigmentation treatment:remove various kinds of pigment such as freckle,chloasma,aged spots,sunburn,etc.
(3)Telangiectasis treatment:treat angiotelec-tasis.
(4)Acne treatment:papule,tuber,Blain,acne,etc.
(5)Shrink pores,tighten skin,improve skin elasticity and glossiness.
(6)Eliminate and smooth wrinkles,acne treatment.